SMART Digest RNase Columns
Thermo Scientific™

SMART Digest RNase Columns

Thermo Scientific SMART Digest™ RNase Columns provide simple, fast and highly reproducible digestion of ribonucleic acid (RNA) to enable oligonucleotide mapping and quantitation.

Have Questions?
Ansicht ändernbuttonViewtableView
KatalognummerEnzym
60140-101RNase T1
60140-102RNase A
Katalognummer 60140-101
Preis (EUR)
1.554,37
Each
Enzym:
RNase T1
Preis (EUR)
1.554,37
Each

Thermo Scientific SMART Digest Immobilized Ribonucleases (Rnases) Columns are designed using the same proven technology as the Thermo Scientific SMART Digest Rnase kits to provide simple, fast and highly reproducible digestion of ribonucleic acid (RNA) in a flow through format.

Obtain high-quality analytical results from mRNA digestions using SMART Digest RNase columns. A significant advance in sample preparation for oligonucleotide mapping, the columns provide fast, simple digestion with high levels of reproducibility, RNase columns use immobilized ribonucleases which allow control of partial digestion to produce required fragments of ideal length for sequencing by HRAM-MS.

Easy and simple

  • Simple process allows control of digestion time ensuring required fragment length for comprehensive mRNA sequencing by HRAM MS
  • Single nuclease digestion allows full characterization of mRNA

Reliable results

  • Increased reproducibility over existing protocols
  • Higher data confidence
  • No nuclease contamination of the analytical column

RNase columns are available with two enzyme specificities:

  • RNase T1 is an endoribonuclease that specifically degrades single-stranded RNA at G residues
  • RNase A is an endoribonuclease that specifically degrades single-stranded RNA at C and U residues
Specifications
SäulenformatImmobilized enzyme
SäulentypImmobilized enzyme in PEEK cartridge
BeschreibungSMART Digest RNase T1 column
Durchmesser2.1 mm
Flussrate10 to 500 μL/min
Zur Verwendung mit (Anwendung)Oligionucleotide Mapping
Länge30 mm
Max. Druck2500 psi (170 bar)
Kompatibilität der mobilen PhaseAmmonium acetate or Tris without saline
Betriebstemperaturbereich20 °C to 50°C
VerpackungsmaterialHydrophilic/coated DVB
Partikelgröße˜20 μm
Porengröße> 1000Å
Stabilität3 years
Stationäre PhaseImmobilized enzyme
Lagerungstemperatur4 °C for extended period of time (refrigerate in Tris without Saline)
VerfahrenBioLC
Gewicht8 g
CleavageDegrades single-stranded RNA at G residues
EnzymRNase T1
TypSMART Digest RNase T1 column
pH7 to 8.5