Confidently identify sample components and rapidly verify materials with less effort so you can make critical decisions fast. Use the compact Thermo Scientific™ Nicolet™ Summit™ FTIR Spectrometer to quickly see pass/fail QC results on the multi-colored LED LightBar located on the front of the instrument. Reduce the number of steps to take measurements, automate workflows and generate reports with the Thermo Scientific™ OMNIC™ Paradigm Software, run on a built-in Windows™ computer. Send and share data in the Cloud with Wi-Fi connectivity. This spectrometer is ideal for busy QA/QC and teaching labs.
Spannung | 110/240 V |
Strahlteiler | KBr/Ge mid-infrared optimized |
Komponenten | LightDrive Optical Engine components: source, laser, interferometer and detector |
Beschreibung | Nicolet Summit X FTIR Spectrometer |
Detektortyp | Fast-recovery deuterated triglycine sulfate (DTGS) |
Abmessungen (T x B x H) | Spectrometer: 32 x 34 x 24 cm (12.7 x 13.3 x 9.6 in.) |
Elektrische Anforderungen | 100/240 V, 47/63 Hz, 110 W |
Zur Verwendung mit (Anwendung) | Quality Control QA/QC; Forensics; Polymers and Plastics; Pharmaceuticals; Environmental; Education; Geology-Gemstone Analysis |
Zur Verwendung mit (Geräte) | Everest Diamond ATR; iD Accessories (iD7 ATR), 100s of standard commercially available accessories |
Quellentyp | Standard: Single-point source with non-migrating hotspot for unmatched data reproducibility |
Spektralbereich | 8000 to 350 cm-1 optimized, mid-infrared KBr beamsplitter |
Spektrale Auflösung | Better than 0.6 cm-1 |
Gewicht (angloamerikanisch) | Spectrometer: 24 lb. |
Gewicht (metrisch) | Spectrometer: 10.9 kg |
Breite (angloamerikanisch) | Spectrometer: 13.3 in |
Breite (metrisch) | Spectrometer: 34 cm |
Unit Size | Each |
Spannung | 100/240 V |
Strahlteiler | KBr/Ge mid-infrared optimized |
Komponenten | LightDrive Optical Engine components: source, laser, interferometer and detector |
Beschreibung | Nicolet Summit PRO FTIR Spectrometer |
Detektortyp | Thermoelectrically cooled (TEC) DTGS for maximum detector response linearity |
Abmessungen (T x B x H) | Spectrometer: 32 x 34 x 24 cm (12.7 x 13.3 x 9.6 in.) Spectrometer with touchscreen: 32 x 53 x 43 cm (12. x 20.8 x 17.0 in.) |
Elektrische Anforderungen | 100/240 V, 47/63 Hz, 110 W |
Zur Verwendung mit (Anwendung) | Polymers and Plastics; Quality Control QA/QC; Pharmaceuticals; Education; Forensics; Geology-Gemstone Analysis; Automotive, Environmental |
Zur Verwendung mit (Geräte) | Everest Diamond ATR; iD Accessories (iD7 ATR), 100s of standard commercially available accessories |
Quellentyp | Standard: Single-point source with non-migrating hotspot for unmatched data reproducibility (10-year warranty) |
Spektralbereich | 8000 to 350 cm-1 optimized, mid-infrared KBr beamsplitter |
Spektrale Auflösung | Better than 0.45 cm-1 |
Gewicht (angloamerikanisch) | Spectrometer weight: 24 lb. Spectrometer weight with touchscreen: 29 lb. |
Gewicht (metrisch) | Spectrometer weight: 10.9 kg Spectrometer weight with touchscreen: 12.6 kg |
Breite (angloamerikanisch) | Spectrometer: 13.3 in Spectrometer with touchscreen: 20.8 in. |
Breite (metrisch) | Spectrometer: 34 cm Spectrometer with touchscreen: 53 cm |
Unit Size | Each |
Spannung | 110/240 V |
Strahlteiler | KBr/Ge mid-infrared optimized |
Komponenten | LightDrive Optical Engine components: source, laser, interferometer and detector |
Beschreibung | Nicolet Summit LITE FTIR Spectrometer |
Detektortyp | Lithium tantalate (LiTaO3) detector |
Abmessungen (T x B x H) | Spectrometer: 32 x 34 x 24 cm (12.7 x 13.3 x 9.6 in.) |
Zur Verwendung mit (Anwendung) | Education; Polymers and Plastics; Quality Control QA/QC; Pharmaceuticals; Forensics; Environmental |
Zur Verwendung mit (Geräte) | Everest Diamond ATR; iD Accessories (iD7 ATR), 100s of standard commercially available accessories |
Quellentyp | Standard: Single-point source with non-migrating hotspot for unmatched data reproducibility (5-year warranty) |
Spektralbereich | 8000 to 350 cm-1 optimized, mid-infrared KBr beamsplitter |
Spektrale Auflösung | Better than 0.6 cm-1 |
Gewicht (angloamerikanisch) | Spectrometer: 24 lb. |
Gewicht (metrisch) | Spectrometer: 10.9 kg |
Breite (angloamerikanisch) | Spectrometer: 13.3 in |
Breite (metrisch) | Spectrometer: 34 cm |
Unit Size | Each |
Katalognummer | Spezifikationen | Packungsgröße | Beschreibung | Preis (EUR) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
912A1139 | Each | Nicolet Summit X FTIR Spectrometer | Angebot anfordern | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
912A0972 | Each | Nicolet Summit PRO FTIR Spectrometer | Angebot anfordern | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
912A1060 | Each | Nicolet Summit LITE FTIR Spectrometer | Angebot anfordern | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|