KingFisher™ Plastics for 96 standard and PCR formats
KingFisher™ Plastics for 96 standard and PCR formats
Thermo Scientific™

KingFisher™ Plastics for 96 standard and PCR formats

Optimieren Sie die Leistung mit Verbrauchsmaterialien, die speziell für den Gebrauch mit KingFisher™ Flex™ Systemen entwickelt wurden und ideal für die Magnetpartikel-Aufreinigung geeignet sind.
Have Questions?
Ansicht ändernbuttonViewtableView
KatalognummerZur Verwendung mit (Geräte)Menge
97002514Nur KingFisher Flex80/Karton
97002560Nur zur Verwendung mit KingFisher Apex50/Karton
97002540KingFisher Flex und Presto48/Karton
97002524KingFisher Flex100/Packung
97002524BKingFisher Apex100/Karton
97002540BKingFisher Apex48/Karton
Katalognummer 97002514
Preis (EUR)
355,65
Online Exclusive
413,00
Ersparnis 57,35 (14%)
Case of 80
Zum Warenkorb hinzufügen
Zur Verwendung mit (Geräte):
Nur KingFisher Flex
Menge:
80/Karton
Preis (EUR)
355,65
Online Exclusive
413,00
Ersparnis 57,35 (14%)
Case of 80
Zum Warenkorb hinzufügen
Optimieren Sie Ihre Leistung mit Thermo Scientific™ KingFisher Kunststoffen, die speziell für die Verwendung mit den KingFisher Flex, Duo Prime, Presto und Apex Geräten entwickelt wurden. KingFisher Geräte verwenden Einweg-Kunststoffplatten und Spitzenkämme aus Polypropylen, die aufgrund ihrer geringen Bindungsaffinität für Biomoleküle ideal für die Magnetpartikelverarbeitung sind. Sowohl die Ausbeute als auch die Qualität des isolierten Proteins oder der Nukleinsäure werden mit speziellen Platten und Spitzenkämmen, die für KingFisher Systeme entwickelt wurden, deutlich verbessert.
Zur Verwendung mit: Thermo Scientific™ KingFisher Geräten, darunter KingFisher Apex, KingFisher Flex und KingFisher Presto.
Begrenzte Garantiezeit:Gemäß den in unseren Allgemeinen Geschäftsbedingungen beschriebenen Garantiebestimmungen und -ausnahmen besteht für dieses Produkt eine Garantie von neunzig (90) Tagen ab dem Versanddatum des Produkts.Aufhebung der Nutzungsbeschränkung auf interne Forschungszwecke:Jegliche dem Käufer auferlegte Beschränkung, das/die Produkt(e) nur zu internen Forschungszwecken zu nutzen, gilt nicht für das/die Produkt(e) auf Webseiten, die diese Erklärung enthalten.
Specifications
BeschreibungKingFisher 96 Spitzenkamm für KingFisher PCR-Magnete, 80 Stück (nur für Flex)
Zur Verwendung mit (Geräte)Nur KingFisher Flex
Menge80/Karton
Fassungsvermögen96 Proben
Format96 Well-Kamm
Unit SizeCase of 80

Häufig gestellte Fragen (FAQ)

I received the KingFisher Flex/KingFisher Duo Prime tip combs and the retaining clips are bent or broken off. When I try to unbend the retaining clips, they break. Can I still use the tip combs if the retaining clips are bent or broken off?

Do not use the tip combs if the clips are bent or missing. Not having clips can cause the tip comb to drop from the holder during the run, which would cause the run to abort. If you received tip combs with bent or broken retaining clips, you can contact Technical Support at techsupport@thermofisher.com to request a free-of-charge replacement.

Find additional tips, troubleshooting help, and resources within our Automated Nucleic Acid Purification Support Center.

What should I do if the tip comb does not load correctly onto my Thermo Scientific KingFisher system?

If the tip does not load correctly onto a Thermo Scientific KingFisher magnetic head, we recommend that you try manually flexing the tips both lengthwise and widthwise to level the tip comb. A video of flexing the tip comb can be found here: https://www.thermofisher.com/us/en/home/life-science/dna-rna-purification-analysis/automated-purification-extraction/kingfisher-systems/resources.html. The video is under "KingFisher Flex" and titled "How to install the magnet head and check the tip comb." Flexing of the tip comb is demonstrated at timepoint 1:35. If that does not work, try a different box or lot of tips. This applies to all KingFisher instruments.

Can I use the same tips and plates for the KingFisher Flex instrument with the 96-well magnetic head and the MagMAX Express-96 instrument magnetic head?

Yes, the KingFisher Flex instrument 96-well magnetic head and the MagMAX Express-96 instrument magnetic head can use the same tip combs and KingFisher plates even though the magnetic heads are different.

I see that the KingFisher 24 Deep Well Head has a processing volume of 5 mL. Does that mean that I can process up to 5 mL of my sample?

No, the processing volume refers to the maximum volume that can be held in the 24 Deep Well plates. This incorporates the volume of binding buffers and beads, so when scaling up reaction volumes, it is important to make sure that the total volume does not exceed 5 mL.

My KingFisher Flex run was stopped due to an error message. Can I start the protocol from where it stopped?

No, once a protocol was stopped, it will restart from the beginning. The extraction procedure can either be finished manually by using a magnetic stand, or a modified version of the original KingFisher Flex script would have to be created that starts off at the point where the run was stopped.