FluoSpheres™ Polystyrene Microspheres, 15 μm, green fluorescent (450/480), for blood flow determination
FluoSpheres™ Polystyrene Microspheres, 15 μm, green fluorescent (450/480), for blood flow determination
Invitrogen™

FluoSpheres™ Polystyrene Microspheres, 15 μm, green fluorescent (450/480), for blood flow determination

Mikrosphären (auch Latex-Beads oder Latexpartikel genannt) sind sphärische Partikel im kolloidalen Größenbereich, die aus einem amorphen Polymer wie Polystyrol hergestelltWeitere Informationen
Have Questions?
KatalognummerMenge
F21010
auch als F-21010 bezeichnet
10 ml
Katalognummer F21010
auch als F-21010 bezeichnet
Preis (EUR)
531,65
Online Exclusive
708,00
Ersparnis 176,35 (25%)
Each
Zum Warenkorb hinzufügen
Menge:
10 ml
Preis (EUR)
531,65
Online Exclusive
708,00
Ersparnis 176,35 (25%)
Each
Zum Warenkorb hinzufügen
Mikrosphären (auch Latex-Beads oder Latexpartikel genannt) sind sphärische Partikel im kolloidalen Größenbereich, die aus einem amorphen Polymer wie Polystyrol hergestellt werden. Unsere Molecular Probes™ FluoSpheres™ Beads werden aus hochwertigem, ultrareinem Polystyrol hergestellt und sind einer breiten Palette an proprietären Farbstoffen beladen, um intensiv fluoreszierende Beads zu erzeugen, die in der Regel wenig oder gar kein Photobleaching aufweisen, selbst wenn sie mit der intensiven Beleuchtung erregt werden, die für die Fluoreszenzmikroskopie erforderlich ist.

FluoSpheres™ Mikrosphären im Bereich von 10–15 µm wurden speziell für regionale Blutflussstudien in Geweben und Organen entwickelt. Üblicherweise werden die Mikrosphären für diese Arten von Studien an den gewünschten Stellen im Kreislaufsystem injiziert und schlussendlich in die Kapillaren eingebracht, wo sie extrahiert werden und die Fluoreszenz quantifiziert werden kann. Die Verwendung fluoreszierender Mikrosphären beseitigt die Strahlungsgefahren und Entsorgungsprobleme, die mit radioaktiv markierten Mikrosphären verbunden sind. Bei guter spektraler Korrektur können bis zu sieben oder mehr gleichzeitig zirkulierende FluoSpheres™ Mikrosphären voneinander unterschieden werden. Mikrosphären, die in Gewebe und Organe perfundiert oder injiziert wurden, behalten ihre Fluoreszenz auch nach einer seriellen histologischen Sektionierung. Unsere FluoSpheres™ Mikrokugeln zur Bestimmung des Blutflusses, die in elf unterscheidbaren Fluoreszenzfarben erhältlich sind, sind auch mit Blutflussanalysatorsystemen kompatibel, die eine automatisierte Extraktion und Analyse durchführen.

FluoSpheres™ Mikrokugeln – Spezifikationen:

Markierung (Anregung/Emission): Grün fluoreszierend (450/480)
Nenndurchmesser der Beads: 15 µm

Auswahl für FluoSpheres™ Fluoreszenz-Mikrokugeln
Neben den Mikrokugeln für Blutflussstudien sehen Sie sich unser komplettes Angebot an fluoreszierenden Mikrokugeln an. Unter diesen Produkten finden Sie Beads mit diesen Auswahlmöglichkeiten:
• Zehn fluoreszierende Farben
• Zehn Nenndurchmesser der Beads: 0,02 µm, 0,04 µm, 0,1 µm, 0,2 µm, 0,5 µm, 1,0 µm, 2,0 µm, 4,0 µm, 10,0 µm und 15,0 µm
• Vier Oberflächenmodifikationen für die Proteinkopplung: Carboxylat, Sulfat, Aldehyd-Sulfat, Amin
• Mikrokugeln, die zusätzlich mit Streptavidin, NeutrAvidin, Biotin, Europium und Platin vorgekoppelt sind

Auswahl für ungefärbte Mikrokugeln
Wir bieten auch Hunderte von Auswahlmöglichkeiten für UltraClean™ tensidfreie Mikrokugeln für Forschungs- und kommerzielle Anwendungen an.

Wir fertigen ein kundenspezifisches Mikrokugelprodukt für Sie an
Wir bearbeiten auf Anfrage Sonderanfertigungen. Beispielsweise können FluoSpheres™ Beads mit Intensitäten vorbereitet werden, die niedriger sind als die unserer regulären Auswahl, was in einigen mehrfarbigen Anwendungen wünschenswert ist. Unser individualisierter Konjugationsservice arbeitet effizient und absolut vertraulich, und wir verbürgen uns für die Qualität unserer Arbeit. Wir sind ISO 9001:2000 zertifiziert.

Nur für Forschungszwecke. Nicht für therapeutische oder diagnostische Zwecke an Tieren und Menschen bestimmt.
Nur für Forschungszwecke. Nicht zur Verwendung bei diagnostischen Verfahren.
Specifications
Konzentration1,0 x 106 Beads⁄ml
ProduktlinieFLUOSPHERES
Menge10 ml
VersandbedingungRaumtemperatur
FarbeGrün
Durchmesser (metrisch)15 μm
MaterialPolystyrol
ProdukttypMikrokugel
Unit SizeEach
Inhalt und Lagerung
Im Kühlschrank (2 bis 8 °C) aufbewahren und vor Licht schützen.

Häufig gestellte Fragen (FAQ)

I want to use fluorescent microspheres for blood tracing studies. What functional group should be on the surface of the beads?

We offer FluoSpheres fluorescent microspheres that are available in 10 and 15 µm diameters, with various wavelengths, for tracer studies. If those sizes or available colors are not optimal for your system, then we recommend the carboxylate-modified microspheres, which are available in a wide range of sizes and colors.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What is the warranty for FluoSpheres microspheres?

The warranty period for FluoSpheres microspheres is 1-year from the date of shipment.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

After washing and centrifugation, there was only a very small pellet left of my microsphere beads and the solution was transparent. Why is this?

Centrifugation is not an effective way to collect smaller microspheres; many particles remain in the solution even if you can visualize a small pellet. For beads less than 1 µm in diameter, we recommend washing by either:

Cross-flow filtration, as these particles have a very high compression modulus and can withstand high g-forces without risk of harm or dialysis with a 500 kDa MWCO
Note: Microspheres greater than 1 µm in diameter can be centrifuged at 1,300 rpm.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I've had my microspheres for over a year, and I'm wondering if they're still good to use. What are some good ways to check their functionality?

Bacterial contamination is the most common cause of microspheres becoming unusable. Many of our particles are supplied with a low level of sodium azide to prevent bacterial contamination, but sometimes this can still occur. Bacterial contamination is best assessed by plating on appropriate growth medium and checking the plates after 72 hr.

Find additional tips, troubleshooting help, and resources within ourMicrospheres Support Center.

I accidentally froze my microspheres; can I still use them?

Even brief freezing can cause irreversible aggregation and potential distortion of the bead shape. You should not use these microspheres.

Find additional tips, troubleshooting help, and resources within our Microspheres Support Center.

Zitierungen und Referenzen (5)

Zitierungen und Referenzen
Abstract
Use of coherent control methods through scattering biological tissue to achieve functional imaging.
Authors:Dela Cruz JM, Pastirk I, Comstock M, Lozovoy VV, Dantus M
Journal:Proc Natl Acad Sci U S A
PubMed ID:15569924
'We test whether coherent control methods based on ultrashort-pulse phase shaping can be applied when the laser light propagates through biological tissue. Our results demonstrate experimentally that the spectral-phase properties of shaped laser pulses optimized to achieve selective two-photon excitation survive as the laser pulses propagate through tissue. This observation ... More
Detection technologies in proteome analysis.
Authors:Patton WF
Journal:J Chromatogr B Analyt Technol Biomed Life Sci
PubMed ID:12015990
'Common strategies employed for general protein detection include organic dye, silver stain, radiolabeling, reverse stain, fluorescent stain, chemiluminescent stain and mass spectrometry-based approaches. Fluorescence-based protein detection methods have recently surpassed conventional technologies such as colloidal Coomassie blue and silver staining in terms of quantitative accuracy, detection sensitivity, and compatibility with ... More
Visualizing regional myocardial blood flow in the mouse.
Authors:Krueger MA, Huke SS, Glenny RW,
Journal:Circ Res
PubMed ID:23513055
The spatial distribution of blood flow in the hearts of genetically modified mice is a phenotype of interest because derangements in blood flow may precede detectable changes in organ function. However, quantifying the regional distribution of blood flow within organs of mice is challenging because of the small organ volume ... More
Effects of gestational age and cortisol treatment on ovine fetal heart function in a novel biventricular Langendorff preparation.
Authors:Fletcher AJ, Forhead AJ, Fowden AL, Ford WR, Nathanielsz PW, Giussani DA,
Journal:J Physiol
PubMed ID:15513943
Structural and functional maturation of a number of fetal organs and physiological systems occurs in the immediate period prior to term, in association with the prepartum increase in fetal plasma cortisol concentration. At present, little is known about how myocardial sensitivity to adrenergic and muscarinic cholinergic stimulation changes as the ... More
Multiplexed spectral signature detection for microfluidic color-coded bioparticle flow.
Authors:Huang NT, Truxal SC, Tung YC, Hsiao AY, Luker GD, Takayama S, Kurabayashi K,
Journal:Anal Chem
PubMed ID:20979407
Here, we report a high-speed photospectral detection technique capable of discriminating subtle variations of spectral signature among fluorescently labeled cells and microspheres flowing in a microfluidic channel. The key component used in our study is a strain-tunable nanoimprinted grating microdevice coupled with a photomultiplier tube (PMT). The microdevice permits acquisition ... More