| ISQ7610-AEI | Vollständige Spezifikationen | Each | ISQ 7610 Large Turbo, No VPI with AEI | Advanced Electron Ionization (AEI) Source for Ultra-Sensitivity and Robustness | Angebot anfordern |
Massenbereich | 1.2–1100 u with unit mass resolution | Typ | Single Quadrupole GC-MS | Detektoren | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | Betriebsarten | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | Scan-Funktionen | Fast Quadrupole Scanning up to 20,000 U/s | Quellentyp | Advanced Electron Ionization (AEI) Source for Ultra-Sensitivity and Robustness | Artikelbeschreibung | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | Beschreibung | ISQ 7610 Large Turbo, No VPI with AEI | Massenstabilität | Better than 0.1 u/48 hours/∆T ≤2 K | Abmessungen | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-VPI | Vollständige Spezifikationen | Each | ISQ 7610 Large Turbo VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | Angebot anfordern |
Massenbereich | 1.2–1100 u with Unit Mass Resolution | Typ | Single Quadrupole GC-MS | Detektoren | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | Betriebsarten | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection, Chemical Ionization (CI), with Positive Ion (PCI) and Negative Ion (NCI) Chemical Ionization, Interchangeable without breaking the vacuum | Scan-Funktionen | Fast Quadrupole Scanning up to 20,000 U/s | Quellentyp | Ultra-Inert ExtractaBrite Ion Source | Artikelbeschreibung | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | Beschreibung | ISQ 7610 Large Turbo VPI with ExtractaBrite | Massenstabilität | Better than 0.1 u/48 hours/∆T ≤2 K | Abmessungen | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-VPICI | Vollständige Spezifikationen | Each | ISQ 7610 Large Turbo, No VPI with AEI | Ultra-Inert ExtractaBrite Ion Source | Angebot anfordern |
Massenbereich | 1.2–1100 u with Unit Mass Resolution | Typ | Single Quadrupole GC-MS | Detektoren | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | Betriebsarten | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection, Chemical Ionization (CI), with Positive Ion (PCI) and Negative Ion (NCI) Chemical Ionization, Interchangeable without breaking the vacuum | Scan-Funktionen | Fast Quadrupole Scanning up to 20,000 U/s | Quellentyp | Ultra-Inert ExtractaBrite Ion Source | Artikelbeschreibung | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | Beschreibung | ISQ 7610 Large Turbo, No VPI with AEI | Massenstabilität | Better than 0.1 u/48 hours/∆T ≤2 K | Abmessungen | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-NOVPI | Vollständige Spezifikationen | Each | ISQ 7610 Large Turbo, No VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | Angebot anfordern |
Massenbereich | 1.2–1100 u with Unit Mass Resolution | Typ | Single Quadrupole GC-MS | Detektoren | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | Betriebsarten | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | Scan-Funktionen | Fast Quadrupole Scanning up to 20,000 U/s | Quellentyp | Ultra-Inert ExtractaBrite Ion Source | Artikelbeschreibung | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | Beschreibung | ISQ 7610 Large Turbo, No VPI with ExtractaBrite | Massenstabilität | Better than 0.1 u/48 hours/∆T ≤2 K | Abmessungen | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods1.2–1100 u with Unit Mass Resolution | Unit Size | Each |
|
| ISQ7610-STNOVPI | Vollständige Spezifikationen | Each | ISQ 7610 Small Turbo, No VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | Angebot anfordern |
Massenbereich | 1.2–1100 u with Unit Mass Resolution | Typ | Single Quadrupole GC-MS | Detektoren | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | Betriebsarten | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | Scan-Funktionen | Fast Quadrupole Scanning up to 20,000 U/s | Quellentyp | Ultra-Inert ExtractaBrite Ion Source | Artikelbeschreibung | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration + | Beschreibung | ISQ 7610 Small Turbo, No VPI with ExtractaBrite | Massenstabilität | Better than 0.1 u/48 hours/∆T ≤2 K | Abmessungen | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|