OdaLog™ L2 Gas Logger
OdaLog™ L2 Gas Logger
Thermo Fisher Scientific™

OdaLog™ L2 Gas Logger

OdaLog™ L2 is a family portable gas loggers primarily designed for the wastewater industry, and are primarily used at a location close to the source of Hydrogen Sulphide (H2S) emissions such as those found within sewerage pumping stations, receiving manholes and inside sewer collection lines.
Have Questions?
Ansicht ändernbuttonViewtableView
KatalognummerMessbereichTyp
LLTF-H2S-2000 bis 200 ppmLangzeitdatenlogger mit Glasfaserverbindung
SL-H2S-500 bis 50 ppmStandard-Datenlogger
LLTF-H2S-10000 bis 1000 ppmLangzeitdatenlogger mit Glasfaserverbindung
SL-H2S-10000 bis 1000 ppmStandard-Datenlogger
SL-H2S-2000 bis 200 ppmStandard-Datenlogger
SL-H2S-20000 bis 2000 ppmStandard-Datenlogger
Katalognummer LLTF-H2S-200
Preis (EUR)
-
Messbereich:
0 bis 200 ppm
Typ:
Langzeitdatenlogger mit Glasfaserverbindung
OdaLog™ L2 is a family portable gas loggers primarily designed for the wastewater industry, and are primarily used at a location close to the source of Hydrogen Sulphide (H2S) emissions such as those found within sewerage pumping stations, receiving manholes and inside sewer collection lines.The OdaLog™ is designed to be corrosion-resistant, robust and able to log data for extended periods of time. With intrinsically safe, wireless data logging, low range detection and multi-gas monitoring options, there is an Odalog™ solution to meet any Hydrogen Sulphide monitoring needs.

The OdaLog™ has been specifically designed to withstand harsh environments typically found in the Wastewater Industry.

The OdaLog™ is primarily used by locating it at or close to the source of Hydrogen Sulphide emissions such as within sewerage pumping stations and receiving manholes.

Its purpose is to monitor gas levels to help control H2S gas in sewerage systems and treatment plants for later review and evaluation using the free-to-download OdaStat-G software.

Key Features

  • Specially designed for harsh wastewater environments
  • Longer battery life (up to 12 months)
  • Simplified record management
  • Real time data
  • Easy to read display
  • Fast and easy data access by Bluetooth™ (Bluetooth version only)
  • Certified intrinsically safe
  • Three different types of L2 loggers:
    • SL — with Standard Term Sensor
    • LL — with Long Term Sensor
    • Fibre — Optic version – with fitting to allow connection of fibre optic cable (for SCADA connection applications)

Typical Applications

  • Gas monitoring in manholes, drains and pits
  • Odour monitoring in sewer and streaming water
  • Ventilation pipes and rising mains
  • Inside sewer collection lines
  • Selected areas in treatment plants
  • Asset management and odour control
Specifications
AkkulaufzeitGreater than 8 months
AkkutypReplaceable C-Size Lithium Battery
Zertifizierung/KonformitätIECExITA 08.0010, Ex ia IIC T4 (TAMB = -20°C to +50°C), Nemko08ATE x 1270, Ex II 2 G, Ex ia IIC T4, IP66/68
DisplaytypLCD alpha numeric display
IP-SchutzartIP66/68
Messbereich0 bis 200 ppm
Auflösung0.1 ppm
ProbentypAir
Arten von SensorenElectrochemical
Gewährleistung12 months
Gewicht (angloamerikanisch)14.8 oz.
Gewicht (metrisch)420 g
Gemessene KomponentenHydrogen Sulfide
TypLangzeitdatenlogger mit Glasfaserverbindung
Unit SizeEach