Genexus™ GX7 Starter Pack-HD
This product is unavailable for sale until further notice. Please consider A40280 as a substitute product.
Genexus™ GX7 Starter Pack-HD
Ion Torrent™

Genexus™ GX7 Starter Pack-HD

The Ion Torrent Genexus GX7 Starter Pack for Ion AmpliSeq HD panels provides one set of all core consumables requiredRead more
Have Questions?
Catalog NumberQuantity
A5022332 reactions
Catalog number A50223
Price (EUR)
13.120,00
Each
Quantity:
32 reactions

The Ion Torrent Genexus GX7 Starter Pack for Ion AmpliSeq HD panels provides one set of all core consumables required to run the Genexus Integrated Sequencer with the GX7 Chip and Genexus Coupler. This starter pack supports flexible, fully automated preparation and normalization of up to 32 Ion AmpliSeq HD libraries, as well as sequencing for up to eight chip lanes (two full chips). The GX7 Chip is used in conjunction with this starter pack and must be ordered separately.

As part of the Genexus Integrated Sequencer GX7 HD workflow, the Genexus GX7 Starter Pack-HD:

  • Automates library preparation, templating, and sequencing for 200 base-read Ion AmpliSeq HD libraries
  • Supports intake variability of clinical research samples in a cost-effective manner
  • Maximizes flexibility with the ability to sequence one to four chip lanes per run
  • Enables parallel processing of up to four compatible assays in a single run
  • Delivers fast and simple instrument set-up, with less than five minutes of hands-on time

The Genexus Integrated Sequencer automates library preparation, sequencing, analysis, and reporting in a hands-off, walkaway workflow to deliver results in a single day. The innovative, multilane sequencing chip is designed to enable cost-effective processing of 1 to 32 single pool libraries.

For Research Use Only. Not for use in diagnostic procedures.
Specifications
No. of Reactions32
Quantity32 reactions
FormatKit
Isolation TechnologyBeads
Unit SizeEach

Frequently asked questions (FAQs)

Can I use the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) with the GX5 Chip?

No, the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) should be used with the GX7 Chip. Each kit allows for the automated template preparation and chip loading of two GX7 chips using the Genexus Integrated Sequencer.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

What are the storage conditions for the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817)?

The Genexus Strip 3-GX7 should be stored at 2-8 degrees C and Genexus Strip 4 should be stored at -30 to -10 degrees C.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

What does the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) consist of?

The Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) consists of 8 pairs of 3-GX7 and 4 strips, allowing for up to 2 sequencing runs per kit.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

What Genexus Software version is compatible with the GX7 Chip?

The GX7 Chip is compatible with the Genexus Software version 6.8.0 and later.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

Can the Genexus Coupler be reused?

The Genexus Coupler should not be reused. The chip and coupler should be changed together.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.