Thermo Scientific™

Orbitrap Ascend Tribrid Mass Spectrometer

Catalog number: FSN06-10003
Thermo Scientific™

Orbitrap Ascend Tribrid Mass Spectrometer

Catalog number: FSN06-10003
Scale your science for proteomics and native protein analysis, with versatility and ease-of-use using the Thermo Scientific™ Orbitrap™ Ascend Tribrid™ mass spectrometer.

 
Catalog Number
FSN06-10003
Unit Size
Each
Description
Orbitrap Ascend Tribrid mass spectrometer, PTCR Ready
Mass Accuracy
<3 ppm RMS using external calibration
Price (EUR)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range>5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy<3 ppm RMS using external calibration
Resolution7500 to 480,000 (FWHM) at m/z 200
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, PTCR Ready
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)

180 kg (400 lb)

Unit SizeEach
Catalog Number
Unit Size
Each
Description
Orbitrap Ascend Tribrid mass spectrometer, Standard
Mass Accuracy
< 3 ppm RMS using external calibration
Price (EUR)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, Standard
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Orbitrap Ascend Tribrid mass spectrometer, EASY-IC Ready
Mass Accuracy
<1 ppm RMS using internal calibration
Price (EUR)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range>5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy<1 ppm RMS using internal calibration
Resolution7500 to 480,000 (FWHM) at

m/z

200
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, EASY-IC Ready
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)

180 kg (400 lb)

Unit SizeEach
Catalog Number
Unit Size
Each
Description
Orbitrap Ascend Tribrid mass spectrometer, ETD Ready
Mass Accuracy
<3 ppm RMS using external calibration
Price (EUR)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range>5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy<3 ppm RMS using external calibration
Resolution7500 to 480,000 (FWHM) at m/z 200
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, ETD Ready
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)

180 kg (400 lb)

Unit SizeEach
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeDescriptionMass AccuracyPrice (EUR)
FSN06-10003Full specifications
EachOrbitrap Ascend Tribrid mass spectrometer, PTCR Ready<3 ppm RMS using external calibrationRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range>5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy<3 ppm RMS using external calibration
Resolution7500 to 480,000 (FWHM) at m/z 200
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, PTCR Ready
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)

180 kg (400 lb)

Unit SizeEach
FSN06-10000Full specifications
EachOrbitrap Ascend Tribrid mass spectrometer, Standard< 3 ppm RMS using external calibrationRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, Standard
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
FSN06-10001Full specifications
EachOrbitrap Ascend Tribrid mass spectrometer, EASY-IC Ready<1 ppm RMS using internal calibrationRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range>5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy<1 ppm RMS using internal calibration
Resolution7500 to 480,000 (FWHM) at

m/z

200
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, EASY-IC Ready
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)

180 kg (400 lb)

Unit SizeEach
FSN06-10002Full specifications
EachOrbitrap Ascend Tribrid mass spectrometer, ETD Ready<3 ppm RMS using external calibrationRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range>5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy<3 ppm RMS using external calibration
Resolution7500 to 480,000 (FWHM) at m/z 200
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, ETD Ready
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)

180 kg (400 lb)

Unit SizeEach
Showing 4 of 4

With its built-in versatility, leading performance, and MSn capabilities, the Orbitrap Ascend Tribrid MS produces high quality data with ease, enabling you to tackle challenging analytes required to scale up your science. Collectively, these features make this instrument uniquely suited for single cell and high throughput proteomics, characterization of complex mixtures of proteins or small molecule-based pharmaceuticals, and deciphering higher-order protein structures.

  • Extended mass range up to 16000 m/z: analyze macromolecules and new modalities while improving detection and sensitivity
  • Front and back IRM: Confidently identify more of the proteome with an additional ion-routing multiple (IRM) to increase scan rate and sensitivity
  • Auto-ready ion source: Spend more time on results, less time on instrument set-up with new the source for autocalibration
  • Real-time library search: Provides higher confidence identifications, now for both peptides and small molecule analysis using MSn data
  • AcquireX workflows: higher coverage for small molecule analysis
  • UVPD: improved fragmentation for top-down proteins, oligos, lipidomics and other analytes
  • PTCR: additional capabilities to analyze proteoforms
  • Easy-ETD: fragments multiply charged precursors including PTMs
  • EASY-IC ion source: sub-1ppm mass accuracy with internal calibration
  • Instrument control software with pre-built, optimized method templates for diverse applications

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text