DataTaker DT80 series comprises a family of data loggers, from five channel data loggers to systems with hundreds of analog inputs and many digital inputs. It measures and logs analog and digital data from numerous electrical sensors or analog instruments, RTDs, thermocouples, temperature sensors, vibrating wire, strain gauges, current loops, voltages, resistance and frequencies. DataTaker models may include an Ethernet port, USB port, Modem for remote access and SMS alerts, WiFi, MODBUS connection, and may include a built-in web server, dEX, for setup and for viewing/downloading of data.
 
Référence
DT80
Taille unitaire
Each
Type
General Purpose Datalogger
Comprend
Logger and accessories
Spécifications complètes
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterie6 V Lead Acid
ComprendLogger and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
Référence
Taille unitaire
Each
Type
General Purpose Datalogger
Comprend
Logger with integrated modem and accessories
Spécifications complètes
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterieNone, external power required
ComprendLogger with integrated modem and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80M
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
Référence
Taille unitaire
Each
Type
General Purpose Datalogger
Comprend
Logger with integrated Wifi and accessories
Spécifications complètes
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterie6 V Lead Acid
ComprendLogger with integrated Wifi and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80W
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
Référence
Taille unitaire
Each
Type
Geotechnical logger supporting vibrating wire strain gauges
Comprend
Logger only (no accessories)
Spécifications complètes
TypeGeotechnical logger supporting vibrating wire strain gauges
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterieNone, external power required
ComprendLogger only (no accessories)
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80G-AL
Types de capteurNumerous, including vibrating wire sensors, thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
Référence
Taille unitaire
Each
Type
Geotechnical logger supporting vibrating wire strain gauges
Comprend
Logger and accessories
Spécifications complètes
TypeGeotechnical logger supporting vibrating wire strain gauges
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterieNone, external power required
ComprendLogger and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80G
Types de capteurNumerous, including vibrating wire sensors, thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
Référence
Taille unitaire
Each
Type
General Purpose Datalogger
Comprend
Logger only (no accessories)
Spécifications complètes
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterie6 V Lead Acid
ComprendLogger only (no accessories)
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80-AL
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
Affichage de 6 sur 6
RéférenceSpécificationsTaille unitaireTypeComprendPrix (EUR)
DT80Spécifications complètes
EachGeneral Purpose DataloggerLogger and accessoriesContactez-nous ›
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterie6 V Lead Acid
ComprendLogger and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
DT80MSpécifications complètes
EachGeneral Purpose DataloggerLogger with integrated modem and accessoriesContactez-nous ›
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterieNone, external power required
ComprendLogger with integrated modem and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80M
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
DT80WSpécifications complètes
EachGeneral Purpose DataloggerLogger with integrated Wifi and accessoriesContactez-nous ›
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterie6 V Lead Acid
ComprendLogger with integrated Wifi and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80W
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
DT80G-ALSpécifications complètes
EachGeotechnical logger supporting vibrating wire strain gaugesLogger only (no accessories)Contactez-nous ›
TypeGeotechnical logger supporting vibrating wire strain gauges
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterieNone, external power required
ComprendLogger only (no accessories)
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80G-AL
Types de capteurNumerous, including vibrating wire sensors, thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
DT80GSpécifications complètes
EachGeotechnical logger supporting vibrating wire strain gaugesLogger and accessoriesContactez-nous ›
TypeGeotechnical logger supporting vibrating wire strain gauges
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterieNone, external power required
ComprendLogger and accessories
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80G
Types de capteurNumerous, including vibrating wire sensors, thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
DT80-ALSpécifications complètes
EachGeneral Purpose DataloggerLogger only (no accessories)Contactez-nous ›
TypeGeneral Purpose Datalogger
Type d’affichageBacklit LCD, 2 line by 16 characters
Mémoire des données128 MB
ÉtalonnageNot Calibrated
Types d’alarmeE-mail, SMS, Physical/Digital Output
Type de batterie6 V Lead Acid
ComprendLogger only (no accessories)
Canaux5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs
InterfaceIncludes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB
Indice IPIP 54
ModèleDT80-AL
Types de capteurNumerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors
Plage d’humiditéMaximum: 85%, non-condensing
Température de fonctionnement (métrique)-30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C)
Dimensions (L x l x H)180 x 137 x 65 mm
Poids (métrique)1.5 kg
Unit SizeEach
Affichage de 6 sur 6

The DataTaker DT80 series comprises a family of industrial data loggers, ranging from five channel data loggers to systems with hundreds of analog inputs and many digital inputs.

The DataTaker DT80 series measures and logs analog & digital data from numerous electrical sensors or analog instruments, RTDs, thermocouples, temperature sensors, strain gauges, current loops, voltages, resistance and frequencies.

DataTaker DT80 models include an Ethernet port, USB port and a built-in web server, dEX for setup and for viewing/downloading of data. In addition:

  • DT80M includes an integrated modem
  • DT80W and DT80GW include integrated WiFi

DataTaker DT80G is specifically suited to geotechnical applications such as slope stability, subsidence, dam wall monitoring, tunnel and mining excavation, ground water, tunnel wall monitoring and site assessment. DT80G supports vibrating wire sensors and other geotechnical sensors.

Other Features:

  • Analog input channels set up as binary logic level inputs.
  • Digital inputs recording ON/OFF states of contacts, or counting pulses over a desired period.
  • Alarm channels and digital outputs to raise alarms (email / SMS / physical digital outputs) or control external processes.
  • Readings may be returned directly or via internal calculations based on a single channel or multiple channels.
  • Internal memory holds ∼10 million readings.
  • Connection to the host computer via Ethernet, USB, and serial Host Port.
  • Separate USB port for USB flash drives to be used for extra storage, or automatic unloading of data from the logger.
  • Built-in battery or auxiliary battery option.
  • Most data logging configurations are easily set up using the graphical web-based dEX interface and a standard web browser.
  • For more complex configurations, a script can be developed using the logger's own scripting language.

Figures

Documentation et téléchargements

Certificats

    Foire aux questions (FAQ)

    Citations et références

    Search citations by name, author, journal title or abstract text