| DT80 | Spécifications complètes | Each | General Purpose Datalogger | Logger and accessories | Contactez-nous › |
Type | General Purpose Datalogger | Type d’affichage | Backlit LCD, 2 line by 16 characters | Mémoire des données | 128 MB | Étalonnage | Not Calibrated | Types d’alarme | E-mail, SMS, Physical/Digital Output | Type de batterie | 6 V Lead Acid | Comprend | Logger and accessories | Canaux | 5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs | Interface | Includes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB | Indice IP | IP 54 | Modèle | DT80 | Types de capteur | Numerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors | Plage d’humidité | Maximum: 85%, non-condensing | Température de fonctionnement (métrique) | -30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C) | Dimensions (L x l x H) | 180 x 137 x 65 mm | Poids (métrique) | 1.5 kg | Unit Size | Each |
|
| DT80M | Spécifications complètes | Each | General Purpose Datalogger | Logger with integrated modem and accessories | Contactez-nous › |
Type | General Purpose Datalogger | Type d’affichage | Backlit LCD, 2 line by 16 characters | Mémoire des données | 128 MB | Étalonnage | Not Calibrated | Types d’alarme | E-mail, SMS, Physical/Digital Output | Type de batterie | None, external power required | Comprend | Logger with integrated modem and accessories | Canaux | 5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs | Interface | Includes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB | Indice IP | IP 54 | Modèle | DT80M | Types de capteur | Numerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors | Plage d’humidité | Maximum: 85%, non-condensing | Température de fonctionnement (métrique) | -30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C) | Dimensions (L x l x H) | 180 x 137 x 65 mm | Poids (métrique) | 1.5 kg | Unit Size | Each |
|
| DT80W | Spécifications complètes | Each | General Purpose Datalogger | Logger with integrated Wifi and accessories | Contactez-nous › |
Type | General Purpose Datalogger | Type d’affichage | Backlit LCD, 2 line by 16 characters | Mémoire des données | 128 MB | Étalonnage | Not Calibrated | Types d’alarme | E-mail, SMS, Physical/Digital Output | Type de batterie | 6 V Lead Acid | Comprend | Logger with integrated Wifi and accessories | Canaux | 5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs | Interface | Includes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB | Indice IP | IP 54 | Modèle | DT80W | Types de capteur | Numerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors | Plage d’humidité | Maximum: 85%, non-condensing | Température de fonctionnement (métrique) | -30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C) | Dimensions (L x l x H) | 180 x 137 x 65 mm | Poids (métrique) | 1.5 kg | Unit Size | Each |
|
| DT80G-AL | Spécifications complètes | Each | Geotechnical logger supporting vibrating wire strain gauges | Logger only (no accessories) | Contactez-nous › |
Type | Geotechnical logger supporting vibrating wire strain gauges | Type d’affichage | Backlit LCD, 2 line by 16 characters | Mémoire des données | 128 MB | Étalonnage | Not Calibrated | Types d’alarme | E-mail, SMS, Physical/Digital Output | Type de batterie | None, external power required | Comprend | Logger only (no accessories) | Canaux | 5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs | Interface | Includes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB | Indice IP | IP 54 | Modèle | DT80G-AL | Types de capteur | Numerous, including vibrating wire sensors, thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors | Plage d’humidité | Maximum: 85%, non-condensing | Température de fonctionnement (métrique) | -30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C) | Dimensions (L x l x H) | 180 x 137 x 65 mm | Poids (métrique) | 1.5 kg | Unit Size | Each |
|
| DT80G | Spécifications complètes | Each | Geotechnical logger supporting vibrating wire strain gauges | Logger and accessories | Contactez-nous › |
Type | Geotechnical logger supporting vibrating wire strain gauges | Type d’affichage | Backlit LCD, 2 line by 16 characters | Mémoire des données | 128 MB | Étalonnage | Not Calibrated | Types d’alarme | E-mail, SMS, Physical/Digital Output | Type de batterie | None, external power required | Comprend | Logger and accessories | Canaux | 5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs | Interface | Includes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB | Indice IP | IP 54 | Modèle | DT80G | Types de capteur | Numerous, including vibrating wire sensors, thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors | Plage d’humidité | Maximum: 85%, non-condensing | Température de fonctionnement (métrique) | -30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C) | Dimensions (L x l x H) | 180 x 137 x 65 mm | Poids (métrique) | 1.5 kg | Unit Size | Each |
|
| DT80-AL | Spécifications complètes | Each | General Purpose Datalogger | Logger only (no accessories) | Contactez-nous › |
Type | General Purpose Datalogger | Type d’affichage | Backlit LCD, 2 line by 16 characters | Mémoire des données | 128 MB | Étalonnage | Not Calibrated | Types d’alarme | E-mail, SMS, Physical/Digital Output | Type de batterie | 6 V Lead Acid | Comprend | Logger only (no accessories) | Canaux | 5 to 15 Analog and 12 Digital (expandable using a CEM20 modules), high speed counter inputs and phase encoder inputs | Interface | Includes SDI-12, Ethernet, MODBUS, RS232, RS422, RS485, USB | Indice IP | IP 54 | Modèle | DT80-AL | Types de capteur | Numerous, including thermocouples, thermistors, temperature sensors, strain gauges and bridge sensors | Plage d’humidité | Maximum: 85%, non-condensing | Température de fonctionnement (métrique) | -30°C to +70°C (reduced battery life and LCD operation outside range -15°C to +50°C) | Dimensions (L x l x H) | 180 x 137 x 65 mm | Poids (métrique) | 1.5 kg | Unit Size | Each |
|