Thermo Scientific™

FHT 6020 Area Monitor Display and Alarms

Référence: HSA32400US
Thermo Scientific™

FHT 6020 Area Monitor Display and Alarms

Référence: HSA32400US

Nuclear facilities need accurate, reliable, sustained early warning of radiation leaks. The Thermo Scientific™ FHT 6020 Area Monitor Display and Alarms offers maximum reliability for permanent operation within nuclear facilities or environmental networks with up to 16 measurement channels that can process and display data from Thermo Scientific intelligent dose rate probes, FH 40 G series probes as well as analog or digital input. All channels can be operated simultaneously, along with audible and visible alarms, to measure and assess the level of gamma and neutron radiation.

 
Référence
HSA32400US
Taille unitaire
Each
Description
Stand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUT
Spécifications complètes
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUT
Type de produitRadiation Detection Alarm
Unit SizeEach
Référence
Taille unitaire
Each
Description
US alarm unit set (Comprising FHT 6025N)
Spécifications complètes
DescriptionUS alarm unit set (Comprising FHT 6025N)
Hauteur (impériale)16.3 in.
Hauteur (métrique)415 mm
Profondeur (impériale)3 in.
Profondeur (métrique)7.6 cm
Poids (impériale)3.1 lb.
Poids (métrique)1.4 kg
Largeur (impériale)5.1 in.
Largeur (métrique)130 mm
BoîtierAluminum
ComprendConnection cable to FHT 6020
Température de stockage (impériale)-4°F to +158°F
Température de stockage (métrique)-20°C to +70°C
Type de produitRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
Référence
Taille unitaire
Each
Description
Network unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cable
Spécifications complètes
DescriptionNetwork unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cable
Poids (impériale)2.8 lb.
Poids (métrique)1.3 kg
BoîtierAluminum
Température de stockage (impériale)-4°F to +158°F
Température de stockage (métrique)-20°C to +70°C
Type de produitRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
Référence
Taille unitaire
Each
Description
Vehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cable
Spécifications complètes
DescriptionVehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cable
Type de produitRadiation Detection Alarm
Unit SizeEach
Référence
Taille unitaire
Each
Description
Stand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Spécifications complètes
DescriptionStand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Type de produitRadiation Detection Alarm
Unit SizeEach
Référence
Taille unitaire
Each
Description
Network unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Spécifications complètes
DescriptionNetwork unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Type de produitRadiation Detection Alarm
Unit SizeEach
Référence
Taille unitaire
Each
Description
Stand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Spécifications complètes
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Type de produitRadiation Detection Alarm
Unit SizeEach
Référence
Taille unitaire
Each
Description
Vehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cable
Spécifications complètes
DescriptionVehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cable
Type de produitRadiation Detection Alarm
Unit SizeEach
Référence
Taille unitaire
Each
Description
Network unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Spécifications complètes
DescriptionNetwork unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Type de produitRadiation Detection Alarm
Unit SizeEach
Référence
Taille unitaire
Each
Description
Stand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filter
Spécifications complètes
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filter
Type de produitRadiation Detection Alarm
Unit SizeEach
Affichage de 10 sur 17Afficher plus
RéférenceSpécificationsTaille unitaireDescriptionPrix (EUR)
HSA32400USSpécifications complètes
EachStand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUTDemander un devis
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUT
Type de produitRadiation Detection Alarm
Unit SizeEach
4255909Spécifications complètes
EachUS alarm unit set (Comprising FHT 6025N)Demander un devis
DescriptionUS alarm unit set (Comprising FHT 6025N)
Hauteur (impériale)16.3 in.
Hauteur (métrique)415 mm
Profondeur (impériale)3 in.
Profondeur (métrique)7.6 cm
Poids (impériale)3.1 lb.
Poids (métrique)1.4 kg
Largeur (impériale)5.1 in.
Largeur (métrique)130 mm
BoîtierAluminum
ComprendConnection cable to FHT 6020
Température de stockage (impériale)-4°F to +158°F
Température de stockage (métrique)-20°C to +70°C
Type de produitRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
HSD-3-2-4-0-0Spécifications complètes
EachNetwork unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cableDemander un devis
DescriptionNetwork unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cable
Poids (impériale)2.8 lb.
Poids (métrique)1.3 kg
BoîtierAluminum
Température de stockage (impériale)-4°F to +158°F
Température de stockage (métrique)-20°C to +70°C
Type de produitRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
HSD32423Spécifications complètes
EachVehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cableDemander un devis
DescriptionVehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cable
Type de produitRadiation Detection Alarm
Unit SizeEach
HSA34423USSpécifications complètes
EachStand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapterDemander un devis
DescriptionStand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Type de produitRadiation Detection Alarm
Unit SizeEach
HSA04400USSpécifications complètes
EachNetwork unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cableDemander un devis
DescriptionNetwork unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Type de produitRadiation Detection Alarm
Unit SizeEach
HSA32423USSpécifications complètes
EachStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapterDemander un devis
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Type de produitRadiation Detection Alarm
Unit SizeEach
HSF32400Spécifications complètes
EachVehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cableDemander un devis
DescriptionVehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cable
Type de produitRadiation Detection Alarm
Unit SizeEach
HSA34400USSpécifications complètes
EachNetwork unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cableDemander un devis
DescriptionNetwork unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Type de produitRadiation Detection Alarm
Unit SizeEach
HSF32423Spécifications complètes
EachStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filterDemander un devis
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filter
Type de produitRadiation Detection Alarm
Unit SizeEach
Affichage de 10 sur 17Afficher plus

The FHT 6020 Area Monitor Display is an industry-proven configurable area monitor capable of stand-alone or network operation.

Measurement Channels

  • Total number of measurement channels: 16
  • Maximum number of FH40G probe channels: 2
  • Maximum number of analog input channels: 2
  • Maximum number of digital input channels: 4

Measurement History

  • Ring buffer storage for > 1000 data entries
  • Measurement memory for probes of the FH40G range

PC/Network Interface (selectable at order)

  • Connection to a local PC or communication adapters (e.a serial to TCP/IP) via RS-232 interface
  • Incorporation in measuring networks via RS 485 interface

Power Supply Options (selectable at order)

  • External DC supply (typ. 24V)
  • International wide range AC
  • Car supply via special DC filter (9V)

Output Channels

  • Maximum number of analog output channels: 2
  • Maximum number of digital output channels: 5

Firmware

  • Equipped with a flash EEPROM storing the firmware, allowing updates
  • Customer-specific programs possible on request

Software

  • Easily and conveniently configured with a PC via serial interface, and through the configuration program FHT 6020.exe.
  • Networking of multiple units and further measurement equipment via Thermo Scientific™ NETVIEW or Thermo Scientific ™VIEWPOINT Software Packages

Figures

Documentation et téléchargements

Certificats

    Foire aux questions (FAQ)

    Citations et références

    Search citations by name, author, journal title or abstract text