Thermo Scientific™

UltiMate™ 3000 Rapid Separation (RS) HPLC Systems

Référence: IQLAAAGABHFAPBMBFF
Thermo Scientific™

UltiMate™ 3000 Rapid Separation (RS) HPLC Systems

Référence: IQLAAAGABHFAPBMBFF

Thermo Scientific™ UltiMate™ 3000 Rapid Separation systems combine unique hardware features and the ability to use small particle columns for fast separations with excellent resolution. All system components are coordinated for high performance. Available in biocompatible and non-biocompatible setups and featuring unique technological innovations like dual-gradient capabilities, the UltiMate 3000 RS systems sustain even most advanced workflows.


Rapid Separation (RS) systems provide ultra-fast separations with ultra-high resolution in an exceptionally versatile HPLC/UHPLC system for the rigorous demands of large and small molecule analysis. These systems operate at pressures up to 1000 bar.


Biocompatible Rapid Separation (BioRS) systems provide UHPLC performance for proteins, peptides, nucleic acids, and biotherapeutics. These systems are 100% corrosion free for use with high salt or extreme pH conditions. They operate with column pressures up to 1000 bar.


UltiMate 3000 RS resources | HPLC Support Center

 
Référence
IQLAAAGABHFAPBMBFF
Taille unitaire
Each
Description
UltiMate 3000 Biocompatible Rapid Separation Dual System
Canaux de solvant
6 canaux ou 2 x 3 canaux
Pression max.
100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur
200 Hz max.
Spécifications complètes
TypeSystème de séparation rapide biocompatible
DescriptionUltiMate 3000 Biocompatible Rapid Separation Dual System
Canaux de solvant6 canaux ou 2 x 3 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
Taille unitaire
Each
Description
UltiMate 3000 Biocompatible Rapid Separation System
Canaux de solvant
2 ou 4 canaux
Pression max.
100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur
Jusqu’à 200 Hz
Spécifications complètes
TypeSystème de séparation rapide biocompatible
DescriptionUltiMate 3000 Biocompatible Rapid Separation System
Canaux de solvant2 ou 4 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteurJusqu’à 200 Hz
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
Taille unitaire
Each
Description
UltiMate 3000 Rapid Separation Dual System
Canaux de solvant
6 canaux ou 2 x 3 canaux
Pression max.
100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur
200 Hz max.
Spécifications complètes
TypeSystème de séparation rapide
DescriptionUltiMate 3000 Rapid Separation Dual System
Canaux de solvant6 canaux ou 2 x 3 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
Taille unitaire
Each
Description
UltiMate 3000 Rapid Separation Quaternary System
Canaux de solvant
4 canaux
Pression max.
100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur
200 Hz max.
Spécifications complètes
TypeSystème de séparation rapide
DescriptionUltiMate 3000 Rapid Separation Quaternary System
Canaux de solvant4 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
Taille unitaire
Each
Description
UltiMate 3000 Rapid Separation Binary System
Canaux de solvant
2 ou 4 canaux
Pression max.
100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur
200 Hz max.
Spécifications complètes
TypeSystème de séparation rapide
DescriptionUltiMate 3000 Rapid Separation Binary System
Canaux de solvant2 ou 4 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
Affichage de 5 sur 5
RéférenceSpécificationsTaille unitaireDescriptionCanaux de solvantPression max.Fréquence d’acquisition de données du détecteurPrix (EUR)
IQLAAAGABHFAPBMBFFSpécifications complètes
EachUltiMate 3000 Biocompatible Rapid Separation Dual System6 canaux ou 2 x 3 canaux100 MPa (15 000 psi/1 000 bar)200 Hz max.Demander un devis
TypeSystème de séparation rapide biocompatible
DescriptionUltiMate 3000 Biocompatible Rapid Separation Dual System
Canaux de solvant6 canaux ou 2 x 3 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
IQLAAAGADGFAMIMBCOSpécifications complètes
EachUltiMate 3000 Biocompatible Rapid Separation System2 ou 4 canaux100 MPa (15 000 psi/1 000 bar)Jusqu’à 200 HzDemander un devis
TypeSystème de séparation rapide biocompatible
DescriptionUltiMate 3000 Biocompatible Rapid Separation System
Canaux de solvant2 ou 4 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteurJusqu’à 200 Hz
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
IQLAAAGABHFAPBMBFESpécifications complètes
EachUltiMate 3000 Rapid Separation Dual System6 canaux ou 2 x 3 canaux100 MPa (15 000 psi/1 000 bar)200 Hz max.Demander un devis
TypeSystème de séparation rapide
DescriptionUltiMate 3000 Rapid Separation Dual System
Canaux de solvant6 canaux ou 2 x 3 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
IQLAAAGABHFAPBMBFASpécifications complètes
EachUltiMate 3000 Rapid Separation Quaternary System4 canaux100 MPa (15 000 psi/1 000 bar)200 Hz max.Demander un devis
TypeSystème de séparation rapide
DescriptionUltiMate 3000 Rapid Separation Quaternary System
Canaux de solvant4 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
IQLAAAGABHFAPBMBEZSpécifications complètes
EachUltiMate 3000 Rapid Separation Binary System2 ou 4 canaux100 MPa (15 000 psi/1 000 bar)200 Hz max.Demander un devis
TypeSystème de séparation rapide
DescriptionUltiMate 3000 Rapid Separation Binary System
Canaux de solvant2 ou 4 canaux
Pression max.100 MPa (15 000 psi/1 000 bar)
Fréquence d’acquisition de données du détecteur200 Hz max.
Gamme de température de colonne5°C à 110°C
Débit max.8mL/min
Unit SizeEach
Affichage de 5 sur 5

Basic HPLC systems

UltiMate 3000 Basic Automated System
Enjoy cost effective, automated HPLC and UHPLC. Ideal for teaching or moderate throughput applications. Includes an isocratic or quaternary pump and integrated autosampler and heated column compartment.

UltiMate 3000 Basic Manual System
Enjoy cost effective access to HPLC and UHPLC separations. System features an isocratic pump and manual sample injection in a simple, expandable system where modularity makes anything possible.

Ensuring Excellent Chromatography

  • Obtain near-zero dead volume connections for optimal peak shapes even over extended periods using Thermo Scientific™ Dionex™ Viper™ Fingertight Fitting system
  • Minimize contamination between samples for more accurate results using ultra-low carryover autosamplers (with loop and needle permanently in the flow path)
  • Get precise and accurate flow rates for stable retention times, robust peak integration, and confident identification using Thermo Scientific™ Dionex™ SmartFlow™ technology
  • Optimize mixing efficiency with adjustable gradient delay volumes via Thermo Scientific™ Dionex™ SpinFlow™ technology

Chromeleon CDS Software Makes Operation Easy

  • Integrated service and validation monitoring with Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System (CDS), versions 6.x and 7.x
  • Automated system startup, standby and shutdown with Chromeleon CDS, versions 6.x and 7.x
  • Compatible with Thermo Scientific™ Chromeleon™ 7.x eWorkflow™ walk-up solution and advanced reporting features

Choose the Right Configuration for You

Basic HPLC Systems

  • Detectors: Diode array, multiple wavelengths, variable wavelength, fluorescence, charged aerosol, refractive index or mass spectrometry detectors
  • Software: Chromeleon 7.3 CDS
  • Fraction Collector: AFC-3000

Basic Automated

  • Pumps: LPG-3400SD or ISO-3100SD
  • Solvent Racks: SR-3000
  • Autosamplers/Column Compartments: ACC-3000T/ACC-3000

Basic Manual

  • Pump: LPG-3400SD or ISO-3100SD
  • Solvent Rack: SR-3000
  • Column Compartment: TCC-3000SD

Figures

Documentation et téléchargements

Certificats

    Foire aux questions (FAQ)

    Citations et références

    Search citations by name, author, journal title or abstract text