Support for Applied Biosystems Thermal Cyclers for PCR

On this page, you will find a collection of information for your Applied Biosystems thermal cycler. We have compiled user guides, technical documents, links to software/firmware, and more.


VeritiPro Thermal Cycler

Overview: The VeritiPro Thermal Cycler has a 96-well (0.2 mL) or a 384-well (0.02 mL) block configuration with a ramp rate of 6.0°C/sec. The 96-well block utilizes 6-zone VeriFlex temperature control technology. The maximum sample throughput is 384 reactions.

 

VeritiPro Thermal Cyclers can also be accessed through Thermo Fisher Connect, giving you the freedom to design and securely upload your methods from any mobile device or desktop computer.

Documentation

Thermal cycler installation, use, and maintenance for the VeritiPro 96-well and 384-well thermal cycler

Access software for the VeritiPro thermal cycler

Technical specifications of the VeritiPro instrument

Technical comparison to the Veriti thermal cycler

Includes VeritiPro product description, information regarding networking and connecting to the cloud, instrument maintenance, and plastics

Application note describing precision temperature control obtained when using VeriFlex Blocks

Describes the Thermal Cycler Fleet Control Software used to manage users, methods, run reports, and multiple PCR instruments

Access updates and patches for Applied Biosystems Thermal Cycler Fleet Control Software


ProFlex PCR System

Overview: The ProFlex PCR System comes in 5 configurations: 3 x 32-well (0.2 mL) (2-zone VeriFlex Block); 96-well (0.2 mL) (6-zone VeriFlex Block); 2 x 96-well (0.2 mL); 2 x flat block; and 2 x 384-well (0.02 mL). The instrument ramp rate is 6.0°C/sec, and the maximum sample throughput is 480,000 reactions.

 

ProFlex PCR Systems can also be accessed through Thermo Fisher Connect, giving you the freedom to design and securely upload your methods from any mobile device or desktop computer.

Documentation

Thermal cycler installation, use, and maintenance for the ProFlex PCR System

Access software for the ProFlex PCR System

Technical specifications of the ProFlex PCR System

Includes ProFlex product description, information regarding networking and connecting to the cloud, instrument maintenance, and plastics

Application note describing precision temperature control obtained when using VeriFlex Blocks

Describes the Thermal Cycler Fleet Control Software used to manage users, methods, run reports, and multiple PCR instruments

Access updates and patches for Applied Biosystems Thermal Cycler Fleet Control Software

Validation study demonstrating effectiveness of amplification using the ProFlex PCR System


SimpliAmp Thermal Cycler

Overview: The SimpliAmp Thermal Cycler has a 96-well (0.2 mL) 3-zone VeriFlex Block and a ramp rate of 4.0°C/sec. The maximum sample throughput is 96 reactions.

 

The SimpliAmp Thermal Cycler can also be accessed through Thermo Fisher Connect, giving you the freedom to design and securely upload your methods from any mobile device or desktop computer.

Documentation

Thermal cycler installation, use, and maintenance for the SimpliAmp Thermal Cycler

Access software for the ProFlex Thermal Cycler

Technical specifications of the SimpliAmp Thermal Cycler

Includes SimpliAmp product description, information regarding networking and connecting to the cloud, instrument maintenance, and plastics

Application note describing precision temperature control obtained when using VeriFlex Blocks

Describes the Thermal Cycler Fleet Control Software used to manage users, methods, run reports, and multiple PCR instruments

Access updates and patches for Applied Biosystems Thermal Cycler Fleet Control Software


MiniAmp Thermal Cycler

Overview: The MiniAmp Thermal Cycler has a 96-well (0.2 mL) block with a ramp rate of 3.0°C/sec. The maximum sample throughput is 96 reactions.

 

The MiniAmp Thermal Cycler can also be accessed through Thermo Fisher Connect, giving you the freedom to design and securely upload your methods from any mobile device or desktop computer.

Documentation

Thermal cycler installation, use, and maintenance for the MiniAmp and MiniAmp Plus Thermal Cyclers

Access software for MiniAmp and MiniAmp Plus Thermal Cyclers

Technical specifications of the MiniAmp and MiniAmp Plus Thermal Cyclers

General instructions for the PCR Starter Kit for the MiniAmp and MiniAmp Plus Thermal Cyclers

Describes the Thermal Cycler Fleet Control Software used to manage users, methods, run reports, and multiple PCR instruments

Access updates and patches for Applied Biosystems Thermal Cycler Fleet Control Software


Automated Thermal Cycler (ATC)

Overview: The Automated Thermal Cycler (ATC) has a 96-well (0.2 mL) block (compatible with full- or semi-skirted plages) or a 384-well (0.02 mL) block with a ramp rate of 3.5°C/sec. The maximum sample throughput is 384 reactions.

Documentation

Thermal cycler installation, use, and maintenance for the Automated Thermal Cycler (ATC)

Access demo software for Automated Thermal Cycler (ATC)

Technical specifications of the Automated Thermal Cycler (ATC)

Includes Automated Thermal Cycler product description, information regarding networking and connecting to the cloud, instrument maintenance, and plastics 

Application note on plate performance using the Automated Thermal Cycler (ATC)

Describes the Thermal Cycler Fleet Control Software used to manage users, methods, run reports, and multiple PCR instruments

Access updates and patches for Applied Biosystems Thermal Cycler Fleet Control Software


Veriti Thermal Cycler

Overview: There are 4 Veriti Thermal Cycler models: 96-well Fast (0.1 mL); Veriti 96-well (0.2 mL); Veriti 384-well (0.02 mL); and 60-well (0.5 mL). All models utilize VeriFlex temperature control technology.

 

Veriti thermal cyclers are no longer offered for sale. The information below is intended to support existing customers of these instruments.

Documentation

Thermal cycler installation, use, and maintenance for the Veriti Thermal Cycler

Access software for Veriti Thermal Cycler

Technical specifications of the Veriti Thermal Cycler

Application note describing precision temperature control obtained when using VeriFlex Blocks


Contact us

Technical support

support.tw@thermofisher.com

 

More information here

For Research Use Only. Not for use in diagnostic procedures.