Model 5028i Continuous Particulate Monitor

Catalog number: 5028I

Model 5028i Continuous Particulate Monitor

Catalog number: 5028I
Conduct simultaneous, real-time measurement of PM10 and PM2.5 and benefit from lower maintenance requirements with the Thermo Scientific™ Model 5028i Continuous Particulate Monitor. The unit combines dual channel sampling technology and beta attenuation analysis on the proven iSeries platform to measure PM10 and PM2.5 simultaneously. The Model 5028i offers continuous, non-stepwise measurement of particulates and complies with U.S. EPA PM-10 (EQPM1102-150) and PM-2.5 (EQPM0609-183).
 
Catalog Number
5028I
Unit Size
Each
Description
Model 5028i Continuous Particulate Monitor
Price (USD)
Full specifications
Height (English)23.43 in.
Height (Metric)59.5 cm
Hertz50/60 Hz
Length (English)22.23 in.
Length (Metric)56.5 cm
Voltage100/120/220/240 V
Weight (English)110 VAC: 77 lb., 220 VAC: 66 lb.
Weight (Metric)110VAC: 35 kg, 220VAC:30 kg
Width (English)18.96 in.
Width (Metric)48.2 cm
Accuracy±5% using NIST-traceable mass foil set
Data AveragingEvery 1 second
DescriptionModel 5028i Continuous Particulate Monitor
Flow Rate16.67 L/min
Inputs16 Digital Inputs (standard), Eight 0 to 10 VDC Analog Inputs (optional) 8 User-Defined Analog Outputs (0 -1 or 0 -5 VDC)
Measurement Ranges0 to 0.1, 1.0, 2.0, 3.0, 5.0, 10.0 mg/m3 0 to 100, 1,000, 2,000, 3,000, 5,000, 10,000 μg/m3
OutputsRS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Output (optional)
Precision±3.0 μg/m3 <80 μg/m3; 4 to 5 μg/m3 >80 μg/m3 (24-hour), RMS Precision: PM2.5 < 5%, PM10 < 5% (24-hour)
Resolution0.1μg/m3
Safety and Electrical DesignationsCE:EN61326-1:2013, EN61326-2-2:2013, IEC/EN61010-1:2010; IEC/EN61010-2-081:2015 UL: 61010-1:2012, UL61010-2-081:2015 CSA: C22.2 No.61010-1:2012, CSA C22.2 No.61010-2-081, ICES-003 Issue 6:2016 FCC: CFR 47 Part 15:2015, ANSI C63.4:2014
Temperature (English) Operating&minus:22° to 113°F
Temperature (Metric) Operating−30° to 45°C
Certifications/ComplianceU.S.EPA PM10 Automated Equivalent Method: EQPM-1102-150; for PM2.5 Automated Equivalent Method: EQPM-0609-183.
Item DescriptionModel 5028i Continuous Particulate Monitor
Power Consumption700 W
Regulatory ComplianceUSEPA PM10 Automated Equivalent Method: EQPM-1102-150; for PM2.5 Automated Equivalent Method: EQPM-0609-183.
Dimensions (L x W x H)22.23 x 18.96 x 23.43 in. (56.5 x 48.2 x 59.5 cm)
Electrical Requirements100-120 VAC, 220-240 VAC, 50/60 Hz
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
5028IFull specifications
EachModel 5028i Continuous Particulate MonitorRequest A Quote
Height (English)23.43 in.
Height (Metric)59.5 cm
Hertz50/60 Hz
Length (English)22.23 in.
Length (Metric)56.5 cm
Voltage100/120/220/240 V
Weight (English)110 VAC: 77 lb., 220 VAC: 66 lb.
Weight (Metric)110VAC: 35 kg, 220VAC:30 kg
Width (English)18.96 in.
Width (Metric)48.2 cm
Accuracy±5% using NIST-traceable mass foil set
Data AveragingEvery 1 second
DescriptionModel 5028i Continuous Particulate Monitor
Flow Rate16.67 L/min
Inputs16 Digital Inputs (standard), Eight 0 to 10 VDC Analog Inputs (optional) 8 User-Defined Analog Outputs (0 -1 or 0 -5 VDC)
Measurement Ranges0 to 0.1, 1.0, 2.0, 3.0, 5.0, 10.0 mg/m3 0 to 100, 1,000, 2,000, 3,000, 5,000, 10,000 μg/m3
OutputsRS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Output (optional)
Precision±3.0 μg/m3 <80 μg/m3; 4 to 5 μg/m3 >80 μg/m3 (24-hour), RMS Precision: PM2.5 < 5%, PM10 < 5% (24-hour)
Resolution0.1μg/m3
Safety and Electrical DesignationsCE:EN61326-1:2013, EN61326-2-2:2013, IEC/EN61010-1:2010; IEC/EN61010-2-081:2015 UL: 61010-1:2012, UL61010-2-081:2015 CSA: C22.2 No.61010-1:2012, CSA C22.2 No.61010-2-081, ICES-003 Issue 6:2016 FCC: CFR 47 Part 15:2015, ANSI C63.4:2014
Temperature (English) Operating&minus:22° to 113°F
Temperature (Metric) Operating−30° to 45°C
Certifications/ComplianceU.S.EPA PM10 Automated Equivalent Method: EQPM-1102-150; for PM2.5 Automated Equivalent Method: EQPM-0609-183.
Item DescriptionModel 5028i Continuous Particulate Monitor
Power Consumption700 W
Regulatory ComplianceUSEPA PM10 Automated Equivalent Method: EQPM-1102-150; for PM2.5 Automated Equivalent Method: EQPM-0609-183.
Dimensions (L x W x H)22.23 x 18.96 x 23.43 in. (56.5 x 48.2 x 59.5 cm)
Electrical Requirements100-120 VAC, 220-240 VAC, 50/60 Hz
Unit SizeEach
Showing 1 of 1

The Model 5028i Continuous Particulate Monitor combines dual channel sampling technology and beta attenuation analysis on the proven iSeries platform to measure PM10 and PM2.5 simultaneously. The Model 5028i monitor offers continuous, non-stepwise measurement of particulates. The key features of this state-of-the-art monitor are:

  • U.S. EPA Approved PM-10 (EQPM1102-150) and PM-2.5 (EQPM0609-183) 
  • Federal Equivalent Method (FEM)
  • Continuous, non-stepwise measurement of PM-10 and PM-2.5 simultaneously
  • Internal backup power to reduce reliable data output time after power off/interruption
  • Filter tape-based monitor, with increased tape volume for longer unattended operation
  • New chassis design to make maintenance and service much easier

Figures

Frequently asked questions (FAQs)

Citations & References