Thermo Scientific™

RMS-3 Digital Area Monitors

Catalog number: RMS3G2DS3
Thermo Scientific™

RMS-3 Digital Area Monitors

Catalog number: RMS3G2DS3
This product has been discontinued. For an alternative, please see FHT 6020 Area Monitor Display and Alarms.
 
Catalog Number
RMS3G2DS3
Unit Size
Each
Description
Cable detector; G2
Price (USD)
Full specifications
TypeCable Detector
DescriptionCable detector; G2
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Digital area monitor (MHV use with external detector)
Price (USD)
Full specifications
TypeDigital Area Monitor
DescriptionDigital area monitor (MHV use with external detector)
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Digital area monitor (BNC connector with external detector)
Price (USD)
Full specifications
TypeDigital Area Monitor
DescriptionDigital area monitor (BNC connector with external detector)
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Digital area monitor (Amphenol connector with DA1-x detectors)
Price (USD)
Full specifications
TypeDigital Area Monitor
DescriptionDigital area monitor (Amphenol connector with DA1-x detectors)
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Digital area monitor with waterproof connector
Price (USD)
Full specifications
TypeDigital Area Monitor
DescriptionDigital area monitor with waterproof connector
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Cable detector; G1
Price (USD)
Full specifications
TypeCable Detector
DescriptionCable detector; G1
Unit SizeEach
Showing 6 of 6
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
RMS3G2DS3Full specifications
EachCable detector; G2Request A Quote
TypeCable Detector
DescriptionCable detector; G2
Unit SizeEach
RMS3C2Full specifications
EachDigital area monitor (MHV use with external detector)Request A Quote
TypeDigital Area Monitor
DescriptionDigital area monitor (MHV use with external detector)
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
RMS3C3Full specifications
EachDigital area monitor (BNC connector with external detector)Request A Quote
TypeDigital Area Monitor
DescriptionDigital area monitor (BNC connector with external detector)
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
RMS3C4Full specifications
EachDigital area monitor (Amphenol connector with DA1-x detectors)Request A Quote
TypeDigital Area Monitor
DescriptionDigital area monitor (Amphenol connector with DA1-x detectors)
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
RMS3C5Full specifications
EachDigital area monitor with waterproof connectorRequest A Quote
TypeDigital Area Monitor
DescriptionDigital area monitor with waterproof connector
Display TypeAlpha-numeric, 12-segment high visibility LED
Linearity±10 (using dead-time compensation) %
Radiation TypeBeta, Gamma, Neutron
Sensitivity0.1μSv/h-100Sv/h
Voltage450 to 2500VDC
Weight (English)5 lb.
Weight (Metric)2.3kg
AlarmsUser-selectable over entire operating range (both Alert and High Alarm)
Operating Temperature (Metric)-40° to +60°C
RangeBackground levels to 10000R/h (0.1µSv/h to 100Sv/h) over any four decades using various standard Thermo Scientific detectors
Threshold0.3 to 60mV (Upper and Lower Thresholds computer controlled)
Unit SizeEach
RMS3G1DS3Full specifications
EachCable detector; G1Request A Quote
TypeCable Detector
DescriptionCable detector; G1
Unit SizeEach
Showing 6 of 6
The built-in wide range high voltage power supply, computer controlled threshold settings, along with numerous other user-programmable parameters, facilitate nearly any pulsed type output detector. This flexibility makes the RMS-3 an excellent choice for new or retrofit installations looking for gamma, neutron, beta, or criticality type systems.
  • Inexpensive, fully featured digital area monitor
  • Standalone or networked operation
  • Large range of supported detectors
  • Alpha-numeric, high visibility LED display
  • Optional integrated HP-270 or HP-290 probe
  • Supports RS-232, RS-485 and ethernet networks
  • Built-in wide range high voltage power supply
  • Computer controlled threshold settings
  • Windows™-based calibration
  • Resilient, splashproof enclosure
  • Simple wall mounted installation

Figures