PageRuler™ Unstained Broad Range Protein Ladder
PageRuler™ Unstained Broad Range Protein Ladder
Thermo Scientific™

PageRuler™ Unstained Broad Range Protein Ladder

Thermo Scientific PageRuler Unstained Broad Range Protein Ladder is a mixture of 11 proteins (5 to 250 kDa) for use詳細を見る
製品番号(カタログ番号)数量
266302x250 μL
製品番号(カタログ番号) 26630
価格(JPY)
21,700
Each
お問い合わせください ›
数量:
2x250 μL
一括またはカスタム形式をリクエストする
Thermo Scientific PageRuler Unstained Broad Range Protein Ladder is a mixture of 11 proteins (5 to 250 kDa) for use as size standards in protein electrophoresis (SDS-PAGE) and western blotting. The protein ladder is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Product features
• Reference bands—the 100, 50, and 20 kDa bands are more intense for easy orientation
• Tagged—bands 10, 15, 20, 30, 40, 50, 70, 100, 150, and 250 contain an integral Strep-tag II sequence and can be detected on western blots using Strep-Tactin conjugates or an antibody against Strep-tag II sequence

Applications
• Accurate protein sizing on SDS-polyacrylamide gels and western blots

研究用途にのみご使用ください。診断目的には使用できません。
仕様
ゲル適合性Bolt™ ビス-トリスプラスゲル、Novex™ トリシンゲル、Novex™ トリス-グリシンゲル、NuPAGE™ ビス-トリスゲル、NuPAGE™ トリス-アセテートゲル、SDS-PAGEゲル
分子量250、150、100、70、50、40、30、20、15、10、5 kDa
製品ラインPageRuler
製品タイプタンパク質ラダー
数量2x250 μL
ロード可能状態
出荷条件Approved for shipment on Wet or Dry Ice
染色タイプ未染色
システムタイプウェスタンブロッティング、SDS-PAGE
Number of Markers11
サイズ範囲5~250 kDa
Unit SizeEach
組成および保存条件
内容: 250 μLのバイアル2本

ストレージバッファー:62.5 mM トリス-H3PO4(25°CでpH 7.5)、1 mM EDTA、2%SDS、10 mM DTT、1 mM NaN3、0.01%ブロモフェノールブルー、および 33%グリセロール

保管:受け取り後、-20°Cで保存

よくあるご質問(FAQ)

The upper bands of the ladder are missing. What could be the reason?

The upper bands of the ladder may be degraded by proteases. Ladder, gel, buffer, pipettes, pipette tips, or equipment can be contaminated by proteases during usage. A general recommendation would be to avoid working with proteases in the same room. We would recommend preparing fresh solutions, cleaning the equipment, and using clean pipettes and tips. If the ladder itself is contaminated, please use a new tube of the ladder.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Some additional bands or smears were observed on the gel when using a PageRuler unstained ladder. What may have caused this?

Additional bands can appear due to dithiothreitol (DTT) oxidation in the storage buffer. Please add newly prepared DTT solution to the final concentration of 100 mM and boil for 5 min at 95 degrees C. This should solve the issue. Addition of DTT is NOT recommended for prestained protein ladders, since too high a concentration of reducing agents can cause protein destaining.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Do the proteins in Thermo Scientific protein ladders have a His-Tag or would otherwise react with an anti-His-Tag antibody?

No, proteins in Thermo Scientific protein ladders are not His tagged. However, non-specific interaction between the ladder proteins and primary or secondary antibodies is possible and some His-Tag detection systems, such as Thermo Scientific 6xHis Protein Tag Stain Reagent Kit, show non-specific interaction. The protein ladder bands are more readily detected when using high antibody concentrations. The non-specific cross-reactivity is difficult to predict, it often has a different pattern dependent on the antibodies used in each individual experiment. The most general way to handle this problem would be to use lower concentrations of antibodies and to use lower amount of protein ladders. It may also be useful to leave one empty well between the ladder and the sample to overcome a possible leakage of the signal to the nearby sample lane.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Can Thermo Scientific protein ladders be detected by Strep-Tactin conjugates?

PageRuler Unstained protein ladders can be detected directly on Western blots by using Strep-Tactin conjugates or an antibody against the Strep-tag II sequence. All PageRuler and Spectra ladder proteins contain an integral Strep-tag II sequence, however the prestained ladders cannot be detected by Strep-Tactin conjugates.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Why is non-specific binding detected after Western blot?

Protein ladder bands can sometimes be detected with chemiluminescent techniques due to non-specific interactions of ladder proteins with either primary or secondary antibodies (or with both). The ladder bands are only rarely detected by chromogenic substrates. The extremely high sensitivity of the chemiluminescent assays is needed to see the bands, so the actual degree of cross-reactivity is low. The non-specific cross-reactivity is difficult to predict, it often has a different pattern depending on the antibodies used. If antibodies recognize a linear epitope, the cross-reactivity may be due to sequence homology. If antibodies react with a denaturation-resistant conformational epitope it could be impossible to identify the exact reason for detected cross-reactivity. The most general way to handle this problem would be to use lower concentrations of antibodies.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.