Dionex™ CarboPac™ PA1 IC 1 mm Columns for Dual EGC Applications
Dionex™ CarboPac™ PA1 IC 1 mm Columns for Dual EGC Applications
Thermo Scientific™

Dionex™ CarboPac™ PA1 IC 1 mm Columns for Dual EGC Applications

Green features

Get accurate, predictable, high-resolution, separation of mono and disaccharides using electrolytically generated potassium methanesulfonate and potassium hydroxide.

製品番号(カタログ番号)カラムタイプ長さ(メートル法)陰イオン交換容量
303272Separator Column250 mm6.25 μeq/column
303273Guard Column50 mm1.25 μeq/column
製品番号(カタログ番号) 303272
価格(JPY)
-
お問い合わせください ›
カラムタイプ:
Separator Column
長さ(メートル法):
250 mm
陰イオン交換容量:
6.25 μeq/column

For predictable high resolution separation of mono-, di-, and some oligosaccharides, use the Thermo Scientific™ Dionex™ CarboPac™ PA1 (1 mm) columns, when operating in Dual EGC mode on Thermo Scientific™ Dionex™ ICS-6000 HPIC™ systems equipped with Thermo Scientific™ Chromeleon™ CDS software. Dual EGC mode enables electrolytic generation of potassium methane sulfonate and potassium hydroxide gradients (KMSA/KOH) gradient eluent for carbohydrate analysis using a Dionex KOH EGC 400 KOH Eluent Generator Cartridge and a Dionex MSA EGC 400 MSA Eluent Generator Cartridge in series. Using the Dual EGC allows for an expanded set of samples for gradient separations of some oligosaccharides along with mono-, di-, and trisaccharide's using electrolytically generated potassium methane sulfonate and potassium hydroxide gradients with a combined concentration up to 200 mM. Many separations require only an isocratic separation. However, some groups of analytes will require a step or gradient elution. Retention of carbohydrates can be varied with eluent concentration, in some cases changing the elution order as the eluent concentration increases.

Combined with pulsed amperometric detection (PAD), this anion-exchange column provides fast, reproducible separations with no need for derivatization. The 1 mm (standard/microbore) Dionex CarboPac PA1, 1 mm columns for Dual EGC contain the same resin as the proven 4 mm and 2 mm Dionex CarboPac PA1 columns, which are used for non-Dual EGC carbohydrate analysis.

Unique advantages of Dionex CarboPac PA1 Columns for Dual EGC

  • Predictable, high-resolution, separation of monosaccharide and disaccharides using electrolytically generated potassium methanesulfonate and potassium hydroxide
  • Rugged all-purpose column to determine monosaccharides and disaccharides in a variety of matrices
  • Column chemistry approved for use in a variety of official methods for the analysis of foods (AOAC Methods 995.13, 996.04, 997.08, 2000.11, 2000.17 and 2001.02)
仕様
陰イオン交換容量6.25 μeq/column
カラム容量6.25 μeq
カラム構造PEEK
使用対象(アプリケーション)Dual EGC Applications
使用対象 (装置)Thermo Scientific Dionex ICS-6000 HPIC Systems Equipped with Thermo Scientific Chromeleon CDS Software
グリーン機能Responsibly packaged
最大圧力4500 psi (310 bar) at 0.063 mL/min.
数量Each
樹脂組成10 μm diameter substrate (polystyrene 2% cross-linked with divinylbenzene) agglomerated with 500 nm microbead quaternary ammonium functionalized latex (5% cross-linked)
固定相Polystyrene 2% Cross-linked with Divinylbenzene
温度(摂氏)4°C to 60°C
カラムタイプSeparator Column
直径(メートル法)1 mm
長さ(メートル法)250 mm
pH0 to 14
Unit SizeEach