Matrix™ 2D Barcoded Open-Top Storage Tubes
Matrix™ 2D Barcoded Open-Top Storage Tubes
Matrix™ 2D Barcoded Open-Top Storage Tubes
Matrix™ 2D Barcoded Open-Top Storage Tubes
Matrix™ 2D Barcoded Open-Top Storage Tubes
Matrix™ 2D Barcoded Open-Top Storage Tubes
Thermo Scientific™

Matrix™ 2D Barcoded Open-Top Storage Tubes

Thermo Scientific™ Matrix™ 2D コード付チューブ オープントップ(材質:PP)はサンプルの保存とトラッキングを可能にします。
製品番号(カタログ番号)容量(メートル法)無菌性ウェル形状Fit for Purpose
37911.4 mLNon-sterileV-bottomPCR Ready
37101.4 mLNon-sterileFlatPCR Ready
3730-110.75 mLNon-sterileV-bottomPCR Ready
3731-110.75 mLNon-sterileV-bottomPCR Ready
3712-111.4 mLSterileFlatSterile and PCR Ready
37111.4 mLNon-sterileFlatPCR Ready
37121.4 mLSterileFlatSterile and PCR Ready
37300.75 mLNon-sterileV-bottomSterile and PCR Ready
37320.75 mLSterileV-bottomSterile and PCR Ready
37340.5 mLNon-sterileV-bottomPCR Ready
3735500 μLSterileV-bottomSterile and PCR Ready
3750500 μLNon-sterileV-bottomPCR Ready
37901.4 mLNon-sterileV-bottomPCR Ready
37921.4 mLSterileV-bottomSterile and PCR Ready
製品番号(カタログ番号) 3791
価格(JPY)
75,100
Case of 960
お問い合わせください ›
容量(メートル法):
1.4 mL
無菌性:
Non-sterile
ウェル形状:
V-bottom
Fit for Purpose:
PCR Ready

Thermo Scientific™ Matrix™ 2D コード付チューブ オープトップ(材質:PP)は、サンプルの保存とトラッキングを可能にします。レーザーエッチング加工された恒久的かつ高コントラストな 2D コードは、化合物、生体試料およびゲノムサンプルの確実な管理とトレーサビリティを提供します。0.5 mL、0.75 mL、1.4 mL の 3 種類の容量をご用意しています。これらのチューブは Thermo Scientific SepraSeal™ セプタムキャップでシール可能であり、-80 °C まで使用できます。

確実なトラッキング:

  • ユニークな 2D コードがすべてのポリプロピレン製チューブの底にレーザーエッチングされており、確実なサンプルの識別とトラッキングが可能
  • 2D コードは 100% DMSO 溶液に対する耐性があり、化合物の処理や保存に最適
  • 2D コードは VisionMate™ High Speed でおよそ 1 秒でスキャンすることができ、高速解読とサンプルトラッキングを実現

堅牢なラックデザイン:

  • Matrix 2D コード付チューブは、特別に設計された積み重ね可能な ANSI 規格のフットプリントをもつ 96 ウェルフォーマットで提供
  • ラッチラックは、超低温フリーザー、冷蔵庫、化合物貯蔵庫、または実験台の貴重なスペースを節約
  • ラッチラックはマルチチャンネルピペットでの分注を容易にし、また、斜めに固定されたリッドはラックをあけたときに実験台に触れないためコンタミネーションリスクを低減
  • 自動化システムでピッキング可能なリッドは、自動分注システムとの併用やハイスループットアプリケーションでの使用に最適

厳密な品質管理:

  • すべての 2D コードの読み取り検査を実施(読み取り性能確認済み)
  • すべての 2D コードはThermo Scientific 2D コード のデータベースと照合され重複がないことを確認
  • チューブの完全性とサンプルの安全性を確保するため、すべてのチューブに対してリークテストを実施

トラッキングソリューション:

  • 個別の保存ニーズに応えるため、Duraseals™、Sepraseals をはじめとするさまざまなシーリングオプションを提供
  • ご要望に応じて、バーコード貼付サービスを提供
  • Thermo Scientific 超低温フリーザーのラックに対応、最適かつ効率よく保存スペースを使用可能

推奨アプリケーション:

個別サンプルの回収、迅速なサンプル識別、アーカイブされたサンプルの確実な識別、サンプルの安全な輸送、サンプルの保存、サンプルの追跡

仕様
バーコード2D BarCoded
容量(ヤードポンド法)0.0473 fl oz.
パッケージ5 Latch Racks of 96 Tubes
製品ラインMatrix
ウェル形状V-bottom
底形状V-bottom
容量(メートル法)1.4 mL
Fit for PurposePCR Ready
材料Polypropylene
無菌性Non-sterile
Unit SizeCase of 960

よくあるご質問(FAQ)

Can I store the Thermo Scientific 2D barcoded storage tubes in standard 10x10 cryoboxes?

Yes, the Thermo Scientific 2D barcoded storage tubes can be stored in standard cryoboxes. However, we do not carry 2D barcode readers capable of reading a full box of 2D barcodes in this storage format.

How do you prevent 2D barcode duplication during manufacturing and ensure quality control of the Thermo Scientific 2D barcoded storage tubes?

The 2D barcode laser etching software includes algorithms that prevent the barcode generator from ever counting backwards, subsequently preventing the re-etching of any previously generated barcode. To verify the above procedure, several quality control checks are performed on the 2D barcodes including:
- Checking for light transmission through the barcode as light transmission will reduce readability
- Inspecting the barcode under magnification
- Reading the barcode on a full rack 2D barcode reader
- Checking the barcode against a database of previously etched 2D barcodes
As the above quality control steps are completed, defective storage tubes are discarded, replaced, and re-checked, ensuring that the 2D barcodes are 100% readable and have not been previously used. This quality control process is the reason why we cannot guarantee sequential 2D barcode printing within a single rack of 2D barcoded products.

Can the barcodes on the Thermo Scientific 2D barcoded storage tubes be damaged by chemicals or by exposure to extreme temperatures?

The Thermo Scientific 2D barcoded storage tubes have been subjected in-house to consecutive liquid nitrogen freeze-thaws followed by submersion in boiling water. These tests did not cause any damage to the 2D barcode.
The 2D barcodes are made of the same material as the storage tubes and are resistant to standard lab chemicals.
The 2D barcode has a built-in ECC200 error barcode correction, which ensures that a damaged barcode is still readable as long as less than 25% of the barcode is missing.