Immuno Standard Modules White and Black
Immuno Standard Modules White and Black
Immuno Standard Modules White and Black
Immuno Standard Modules White and Black
Immuno Standard Modules White and Black
Immuno Standard Modules White and Black
Immuno Standard Modules White and Black
Thermo Scientific™

Immuno Standard Modules White and Black

Conduct fluorescence- and luminescence-based immunoassays and binding assays using these immuno standard modules white and black.
製品番号(カタログ番号)容量(メートル法)ウェル表面処理
437591350μLMaxiSorp
437702350 μLPolySorp
437915明確な350 μLMaxiSorp
475515ブラック400 μLMaxiSorp
475523ブラック400μLPolySorp
7566380 μLHydrophobic
製品番号(カタログ番号) 437591
価格(JPY)
71,120
온라인 행사
Ends: 27-Mar-2026
88,900
割引額 17,780 (20%)
Case of 60
お問い合わせください ›
色:
容量(メートル法)ウェル:
350μL
表面処理:
MaxiSorp

Thermo Scientific™ イムノモジュール (白色 & 黒色) を使用して、蛍光および発光の免疫測定やバインディングアッセイができます。

特徴:
  • 8、12、または 16 ウェルストリップから選択できます。
  • 最適なアッセイを実現できるよう、フレーム付/フレームなしを選択できます。
  • 平底ウェルまたは C 底ウェル
  • 最適な結合能を得られるよう、3 つの表面タイプから選択できます
  • 白色プレートは、シグナル反射が可能な限り高く、バックグラウンドの蛍光が低いため、落射蛍光測定に最適です
  • 黒色プレートでは、落射蛍光測定で発生しがちな後方散乱光が低減されます
  • 透過/透明プレートは、時間分解蛍光アプリケーションのみで使用できます
  • 表面処理の選択肢:

  • Thermo Scientific™ PolySorp™ および Microlite™ 1+ は、疎水性分子の吸着に使用します。
  • Microlite 2+ は弱親水性で、さまざまな生体分子を結合します。
  • Thermo Scientific™ MaxiSorp™ は親水性で、抗体を用いたサンドイッチ法に最適です。

  • 限定的保証期間: 当社の販売契約条件で規定されている保証要件および例外事項に従い、この製品は出荷日から90日間保証されます。

    内部研究への使用制限に関する免責条項: この製品の内部研究目的の限定使用に関する購入者への制限は、この条件に関連したウェブページの製品には適用されません。

    仕様
    結合特性Hydrophilic
    結合タイプAdsorption
    分解No
    認証済みYes
    検出法Chemiluminescence
    使用対象(アプリケーション)Fluorescence and Luminescence
    蓋なし
    箱あたりの入数60
    パックあたり入数5
    パッケージ60 Cases
    プレートブロッキングなし
    製品タイプMicroplate Strip
    標的分子Antibodies (Glycoproteins)
    容量(メートル法)使用可能250μL
    アレイ8 x 12
    フォーマットStandard
    材料Polystyrene
    ウェル数96
    表面処理MaxiSorp
    容量(メートル法)ウェル350μL
    ウェル形状Round, C Bottom
    Unit SizeCase of 60

    よくあるご質問(FAQ)

    What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

    We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
    One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

    Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

    Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
    Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

    For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

    The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
    - Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
    - Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
    - "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
    - StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

    What is the difference between certified and non-certified MaxiSorp plates and modules?

    Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.

    How can I reduce high background readings and non-specific binding, when performing ELISA using Nunc-Immuno MaxiSorp Plates?

    Assay sensitivity depends strongly on efficient removal of non-specific reacting molecules. High background readings and coating instability can be minimized by addition of a blocking step after the first coating. The excess surface is then occupied by indifferent molecules.
    We recommend washing three times after each coating step by using a solution of 0.15 M phosphate buffer (pH 7.2) with 0.2 M NaCl and 0.05% Tween 20.
    For blocking, we recommend using 0.5% BSA, 1% casein or 1% gelatin in 0.15 M phosphate buffer (pH 8.2) or carbonate buffer (pH 9.6).