Applied Biosystems™

TaqMan™ Copy Number Reference Assay, human, TERT

製品番号(カタログ番号): 4403316
Applied Biosystems™

TaqMan™ Copy Number Reference Assay, human, TERT

製品番号(カタログ番号): 4403316
製品番号(カタログ番号)
4403316
ユニットサイズ
750 reactions
価格(JPY)
製品番号(カタログ番号)
ユニットサイズ
3,000 reactions
価格(JPY)
製品番号(カタログ番号)ユニットサイズ価格(JPY)
4403316750 reactions
44033153,000 reactions
製品概要
ビデオ
推奨事項
推奨事項
参考資料
FAQ
引用および参考文献
その他の情報
推奨事項
Human TaqMan™ Copy Number Reference Assays are run with human TaqMan™ Copy Number Assays in a duplex real-time PCR reaction to detect and measure copy number variations (CNVs) and smaller regions in the human genome. Two options for genes that can be used as endogenous reference genes in humans are offered: RNase P and TERT. TaqMan™ Copy Number Reference Assays are designed to unique genomic sequences in the reference genome assembly (Build 37/hg19) and are required for relative quantitation of copy number targets.

TaqMan™ Copy Number Assays quantitate the gene of interest and normalize to an endogenous reference gene known to be present in two copies in a diploid genome. Please note that TaqMan™ Copy Number Reference Assays are species specific.

TERT: The Alternative Reference Gene Option
TaqMan™ Copy Number Reference Assays have a VIC™ dye–labeled TAMRA™ probe and reference sequence–specific forward and reverse primers. The assays are not primer-limited.

TaqMan™ Copy Number Reference Assay RNase P is recommended as the standard reference assay for copy number analysis. This assay detects the Ribonuclease P RNA component H1 (H1RNA) gene (RPPH1) on chromosome 14, cytoband 14q11.2. The assay location is chr.14:20811565 on NCBI build 37. It has an 87 bp amplicon that maps within the single exon RPPH1 gene.

TaqMan™ Copy Number Reference Assay TERT is an alternative reference assay; it is recommended in the event that the RNase P assay functions poorly with a sample because of chromosomal aberrations or other issues. This assay targets the telomerase reverse transcriptase (TERT) gene located on chromosome 5, cytoband 5p15.33. The assay location is chr.5:1253373 on NCBI build 37. It has an 88 bp amplicon that maps within exon 16 of the TERT gene.

Simplest Copy Number Analysis Workflow
TaqMan™ Copy Number Assays have the simplest workflow of all currently available copy number analysis methods. The test assay (FAM™ dye–labeled), the reference assay (VIC™ dye–labeled), your sample DNA, and TaqMan™ Master Mix are combined and then run on an Applied Biosystems™ real-time PCR system using the standard TaqMan™ Copy Number Assay protocol. On average, setup to primary analysis takes only 3–4 hr (including an approximately 2 hour PCR run).

Powerful Data analysis Software
CopyCaller™ Software was developed specifically for TaqMan™ Copy Number Assay data analysis. This free, easy-to-use software utilizes a graphical interface that quickly calculates the possible copy numbers for a set of samples in a run. It also gives a confidence value for each copy number call, and has outlier functionality.

For Research Use Only. Not for human or animal therapeutic or diagnostic use.
For Research Use Only. Not for use in diagnostic procedures.

仕様

3'プライマー修飾
None
5'プライマー修飾
None
検出法
Primer-probe
形状
Frozen
フォーマット
Tube
GC-Rich PCR Performance
Low
PCR法
qPCR
反応速度
Standard
遺伝子記号
TERT
グリーン機能
Sustainable packaging
内部プローブの変更
TAMRA™ Quencher (3'), VIC™ (5')
標識または色素
VIC
製品ライン
TaqMan™
製品タイプ
Configurable Assay
精製方法
HPLC
純度または品質グレード
RNase-Free, DNase-Free
出荷条件
Dry Ice
Human
対応可能対象
750 Reactions
ターゲット
Tert (Telomerase Reverse Transcriptase)
濃度
20X
反応数
750 Reactions

組成および保存条件

Control Primer-Probe Set(s)

ドキュメントおよびダウンロード

証明書

    よくあるご質問(FAQ)

    引用および参考文献

    Search citations by name, author, journal title or abstract text