MeltDoctor™ HRM Calibration Plate, Fast 96-well
Product Image
Applied Biosystems™

MeltDoctor™ HRM Calibration Plate, Fast 96-well

Applied Biosystem® ready-to-use MeltDoctor™ HRM Calibration Plates contain all the components required for pure dye and HRM calibration, reducing the詳細を見る
製品番号(カタログ番号)数量
44256181 x 96-well plate
製品番号(カタログ番号) 4425618
価格(JPY)
70,500
Each
お問い合わせください ›
数量:
1 x 96-well plate
Applied Biosystem® ready-to-use MeltDoctor™ HRM Calibration Plates contain all the components required for pure dye and HRM calibration, reducing the complexity of getting started with HRM experimentation. These plates provide thermal and optical calibration required for accurate and reproducible discrimination between melt curves.
研究用途にのみご使用ください。診断目的には使用できません。
仕様
校正済み色素HRM (High Resolution Melting) Dye
校正タイプThermal Calibration, Optic Calibration
使用対象(アプリケーション)Real Time PCR (qPCR)
使用対象 (装置)7500 Fast System, 7900HT Fast System
フォーマット96-well Plate
プレートの適合性Calibration Plate
製品ラインMeltDoctor
数量1 x 96-well plate
反応速度Fast
出荷条件Dry Ice
製品タイプHRM Calibration Plate
Unit SizeEach
組成および保存条件
1 plate, 96-well fast format

Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

よくあるご質問(FAQ)

HRM解析では何が測定できますか?

HRM解析ではジェノタイピング、Mutationの検索、およびメチル化解析が可能です。

HRM解析を行う際に必要な試薬は何ですか?

HRM解析を行う場合は、装置とソフトウェアのHRM蛍光キャリブレーションを行うための試薬が必要です。

High Resolution Melt (HRM)が使用できる機種は何ですか?

7500F, 7900HT Fast, StepOne/StepOnePlus, QuantStudio 3/5では、HRMソフトウェアを別途ご購入の上、ご利用可能です。以下の機種に関しましては、ソフトウェアにすでに組み込まれているHRMモジュールにて、HRMの機能がご利用可能です。 ViiA7, QuantStudio 6, QuantStudio7, および QuantStudio 12K Flex。HRMモジュールをご使用になる場合は、ライセンスを別途購入する必要があります。

How long should the amplicon be for HRM analysis?

We recommend to use 50-250 bp long PCR amplicons. Typically, shorter amplicons can distinguish the genotypes for a SNP better, especially for Type III and Type IV SNPs. This is simply because a single base variation affects the melting behavior of a 100 bp amplicon stronger than of a 500 bp amplicon, for example. In longer fragments, the risk of covering multiple mutations is also increased.

What can be used as positive control reactions in HRM analysis?

Positive control reactions should contain template DNA with a known sequence. In SNP genotyping experiments, this could be a sample with a known genotype. Positive control(s) for all genotypes should be included where possible to serve as a reference in melting curve comparison and assigning genotypes for test samples. In mutation scanning experiments, a sample with a wild type sequence could serve as a positive control. The controls should preferably have the same DNA concentration as their corresponding test samples. Control DNA should also be eluted and/or diluted in the same buffer as the samples.