3500 Genetic Analyzer for Resequencing
3500 Genetic Analyzer for Resequencing
Applied Biosystems™

3500 Genetic Analyzer for Resequencing

This 8-capillary Genetic Analyzer is specifically configured with software for resequencing applications.We set a new standard in capillary electrophoresis with詳細を見る
製品番号(カタログ番号) 4440466
価格(JPY)
-
お問い合わせください ›
This 8-capillary Genetic Analyzer is specifically configured with software for resequencing applications.

We set a new standard in capillary electrophoresis with the 8-capillary 3500 Genetic Analyzer. These instruments are specifically designed to support the demanding performance needs of validated and process controlled environments, while retaining the unsurpassed application versatility that life science researchers expect from us.

• An 8 capillary system that can easily be upgraded to a 24-capillary system when you’re ready.
• New single-line 505 nm, solid-state long-life laser – utilizes a standard power supply; requires no heat-removal ducting.
• Powerful, integrated data collection and primary analysis software provides real-time assessment of data quality.
• Radio Frequency Identification (RFID) technology tracks key consumables data and records administrative information.
• Advanced multiplexing capabilities for DNA fragment analysis with up to six unique dyes.
• Unrivaled application flexibility – one array and one polymer are used for most applications.
• Simple setup, operation and maintenance – the easiest-to-run, easiest-to-own DNA sequencer to date.

Accurate Reliable Data Quality
The 3500 series systems significantly improves signal uniformity from instrument-to-instrument, run-to-run, and capillary-to-capillary. With a combination of intelligent hardware, powerful new algorithm and reagent combinations, these methods provide major reduction in the range of signal peak heights obtained across multiple 3500 series instruments (see figure 1).

Improved Sizing Precision
New thermal sub-system design gives enhanced performance in demanding fragment applications enabling improved sizing precision versus previous generations of capillary electrophoresis platforms (see figure 2).

Ready to Use Consumables With RFID Tags
The 3500 series introduces ready-to-use consumables with pre-packaged polymer pouches, cathode and anode buffer containers and easy-to-install capillary arrays. Each of these consumables is integrated with RFID tags that enable viewing, tracking and reporting of critical information about reagents and consumables including usage, lot number, part number, expiry date and on-instrument lifetime within the 3500 Series Data Collection Software (see figures 3 and 4).

Easy to Use New Data Collection Software
3500 Series Data Collection software breaks new ground in user-friendly navigation with an intuitive dashboard design, highly visible buttons for common operations, easy-to-read graphical displays to monitor the state of consumables and handy maintenance scheduling calendar functionality. New functionality includes simplified plate set-up, built-in primary analysis with quality control, so you can make decisions about the quality of data as it is produced on the instrument without the need to transfer output files into secondary analysis software packages (see figures 4 & 5).

For Research Use Only. Not for use in diagnostics procedures.
For Research Use Only. Not for use in diagnostic procedures.
仕様
アンペア数15 A
キャピラリー長50 cm, 36 cm
電気的要件100 V to 240 V, 50/60 HZ, 15 A
外部コンピューターHard Drive: 2x 500GB SATA 3.0 Gb/s and 8 MB Data Burst Cache, Memory: 16 GB (2x 8GB) 1600 MHz DDR3 Non-ECC. 4th Gen Intel Core I7 Processor- 3.1 GHz Turbo Processor, Operating System: Windows 7 SP1, Hardware: Pentium™ IV Processor - 1.86 GHz Processor, Hard Drive: 1 x 80GB 7200 RPM SATA 3.0Gb⁄s and 8MB Data Burst Cache, Operating System: Windows™ Vista™ SP1, Installed RAM: 2GB
使用対象 (装置)3500 Genetic Analyzer Capillary Array (50 cm), POP-6™ Polymer for 3500⁄3500xL Genetic Analyzers, POP-4™ Polymer for 3500⁄3500xL Genetic Analyzers, 3500 Genetic Analyzer Capillary Array (36 cm), POP-7™ Polymer for 3500⁄3500xL Genetic Analyzers
フォーマット96-well Plate, 8-tube Strip
高さ(ヤードポンド法)外部28.34 in.
高さ(メートル法)外部72 cm
長さ(ヤードポンド法)外部24.01 in.
長さ(メートル法)外部61 cm
最大電圧Electrophoresis Voltage - Up to 20 kV
キャピラリー数8 Capillaries
操作環境Humidity: 20%-80% (non-condensing), Room temp: <2° fluctuation during runs, Temperature: 15°C-30°C
動作システムWindows 7 (Service Pack 1)
ポリマーPOP-4™, POP-6™, POP-7™
ポリマー消費量Replace at earliest of 7 days⁄384 samples⁄60 Injections (384-sample pouches), Replace at earliest of 7 days⁄960 samples⁄120 Injections (960-sample pouches)
数量1 system
リード長≥850 bp using a 50 cm capillary and POP-7™
ソフトウェア互換性Variant Reporter™ Software, GeneMapper™ Software
スループットUp to 368 samples per day (using run module ShortReadSeq POP7)
保証1 Year Limited Warranty on Parts and Labor, Service Installation and Application Training Included
重量82 kg (approximately)
幅(ヤードポンド法)外部24.01 in.
幅(メートル法)外部61 cm
Software TypeData Collection Software
原料DNA
Unit SizeEach
パッケージ構成
4387646
製品番号(カタログ番号)
4387646
ユニットサイズ
数量
1
4397722
製品番号(カタログ番号)
4397722
ユニットサイズ
数量
1
4405673
製品番号(カタログ番号)
4405673
ユニットサイズ
1 system
数量
1

よくあるご質問(FAQ)

How can I set up auto-analysis for data in GeneMapper with the 3500 Data Collection Software version 3.x?

Beginning with 3500 Data Collection Software version 3, the 3500 Data Collection Software does not support automatic secondary analysis. This is also indicated in the software release notes. To perform secondary data analysis, you will need to manually import the .fsa file into the GeneMapper software. For optimal performance, we recommend that you install the GeneMapper Software on a stand-alone computer that is not part of the 3500 Genetic Analyzer system.

Find additional tips, troubleshooting help, and resources within our Fragment Analysis Software Support Center.

Is the Plate Septa, 96 well (Cat. No. 4315933) compatible with 3500/3500xL Genetic Analyzers?

Yes, it is compatible with all versions of 3500/3500xL Genetic Analyzers as well as the 3500/3500xL Dx Genetic Analyzers, specifically in RUO mode.

Can I run SNaPshot applications, between 35 and 120 bp, on the SeqStudio Genetic Analyzer and the Applied Biosystems 3500 Genetic Analyzer with a 50 cm capillary array?

Both the SeqStudio Genetic Analyzer and the Applied Biosystems 3500 Genetic Analyzer have run modules specific for the SNaPshot application.

- For the 3500 Genetic Analyzer, the run module is "SNaPshot50_POP7" and it has a ~30 minute run time.
- For the SeqStudio Genetic Analyzer, the run module is "SNaPshot", the optimal size range is 40-120 bp, and it runs for ~25 minutes but the 35 bp fragment will be collected.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Software Support Center.

Is there a way to automatically upload my data into the Thermo Fisher Cloud app directly from the Applied Biosystems 3500 Genetic Analyzer, instead of using Data Collection Software?

If you are using the most recent version of Data Collection Software (v3.3), there is a way to automatically upload your data into the Thermo Fisher Cloud app from the instrument. When a run is complete, the data is stored in the results group folder that is specified in the plate record. The data will be automatically uploaded to your account if your User ID is the active ID. Results are saved in your account folders named by the plate and injections, not in the results group folder. Please go to page 43 of the 3500/3500xL Genetic Analyzer User Guide for Data Collection Software v3.3 (https://assets.thermofisher.com/TFS-Assets/LSG/manuals/100079380_3500v3_3RUO_UG.pdf) for details regarding the Thermo Fisher Cloud app.

If you are using Data Collection Software v3.1, you would have to manually upload your data into the Thermo Fisher Cloud app from your data folder on the computer.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.