Megaplex™ Primer Pools, Human Pools B v3.0
Product Image
Applied Biosystems™

Megaplex™ Primer Pools, Human Pools B v3.0

Green features
Megaplex™ Primer Pools, Human Pools B v3.0 is available under a single part number containing both the Megaplex™ RT Primers詳細を見る
製品番号(カタログ番号)数量
444474950 reactions
製品番号(カタログ番号) 4444749
価格(JPY)
179,500
Each
お問い合わせください ›
数量:
50 reactions
Megaplex™ Primer Pools, Human Pools B v3.0 is available under a single part number containing both the Megaplex™ RT Primers and Megaplex™ PreAmp Primers, Human Pools B v3.0. Megaplex™ RT Primers, Human Pool B v3.0 contains RT primers for 377 unique microRNAs and 4 controls. For use when assay sensitivity of the utmost importance, Megaplex™ PreAmp Primers significantly enhance the ability to detect low expressed microRNAs enabling the generation of a comprehensive expression profile using far less sample, as low as 1 ng of input total RNA. The microRNA targets represented in this pool tend be less well characterized, more narrowly expressed and⁄or expressed at a lower level compared to Human Pool A. Megaplex™ Primer Pools, Human Pools B v3.0 are intended for use with the TaqMan® Array Human MicroRNA B Card v3.0, however, they can also be used to prepare cDNA for real-time analysis using the individual TaqMan® MicroRNA Assays.
研究用途にのみご使用ください。診断目的には使用できません。
仕様
グリーン機能Sustainable packaging
反応数50反応
プライマーRT Primers, PreAmp Primers
製品ラインMegaplex
製品タイプPrimer Pool
数量50 reactions
Human
対応可能対象50 Reactions
使用対象(アプリケーション)miRNA analysis
GC-Rich PCR Performance
PCR法qPCR
Unit SizeEach
組成および保存条件
Store at -20°C

よくあるご質問(FAQ)

Can Ct's greater than a cut-off be considered valid results?

Yes they can. However, it is important to recognize the true linearity and detection limits of your assay: Ct values above the cut-off can indicate non-specific amplification, unless your NTC is a true- no-target control, and you have run a statistically significant number of replicates. Any results with Ct above the recommended cut-off need to be validated with individual assays on plates.

What is a good Ct cut-off for the TaqMan MicroRNA Array Cards and TaqMan Advanced miRNA Array Cards? In other words, beyond what Ct should I not trust the data?

The typical Ct cut-off on TaqMan Array Cards is 32, which is equivalent to Ct 35 on a plate (10 µl reaction). Previous studies show that if you use pre-amplification, a Ct cut-off of 29 or 30 can be used to reduce numbers of false positives (see Technical Note Optimized protocols for human or rodent microRNA profiling with precious samples). To ensure that you have selected a correct cut-off, you should run replicates of the same sample and use Ct cut-off before you see an increase in the Standard Deviation.