Clear C-Shaped Immuno Nonsterile 96-Well Plates
Clear C-Shaped Immuno Nonsterile 96-Well Plates
Clear C-Shaped Immuno Nonsterile 96-Well Plates
Clear C-Shaped Immuno Nonsterile 96-Well Plates
Clear C-Shaped Immuno Nonsterile 96-Well Plates
Thermo Scientific™

Clear C-Shaped Immuno Nonsterile 96-Well Plates

Perform quantitative and qualitative solid phase immunoassays with these nonsterile 96-well plates, available in a variety of binding surfaces.
製品番号(カタログ番号)表面処理認証済み
446612MaxiSorpYes
430341MaxiSorpNo
446140PolySorpNo
製品番号(カタログ番号) 446612
価格(JPY)
38,340
Case of 60
お問い合わせください ›
表面処理:
MaxiSorp
認証済み:
Yes
Thermo Scientific™ クリア 96 ウェルイムノ未滅菌プレート C 底は、Nunc™、Immulon™ および Microtiter™ プレートを含む製品で、定量的および定性的な固相イムノアッセイを実施できます。比色法で信頼性と再現性のある結果を実現するため、さまざまな結合表面から選択できます。

96 ウェルソリッドプレート:

  • クリアのポリスチレン製
  • 最適な結合能を得るため、複数の表面から選択可能
  • 行と列には英数字を刻印
  • 表面:

  • Thermo Scientific™ PolySorp™ は、疎水性分子の吸着に使用します。
  • Thermo Scientific™ MaxiSorp™ は親水性で、抗体サンドイッチ法に最適です。
  • ご注文情報:

    販売状況は国によって異なる場合がありますのでご注意ください。446612 には証明書が含まれています。

    各ロットは IgG 結合に関して機能試験済み

    限定的保証期間: 当社の販売契約条件で規定されている保証要件および例外事項に従い、この製品は出荷日から90日間保証されます。

    内部研究への使用制限に関する免責条項: この製品の内部研究目的の限定使用に関する購入者への制限は、この条件に関連したウェブページの製品には適用されません。

    仕様
    結合特性Hydrophilic
    認証済みYes
    検出法Colorimetric
    蓋なし
    箱あたりの入数60
    パックあたり入数5
    パッケージ60 Cases
    プレートブロッキングなし
    製品タイプマイクロプレート
    標的分子Antibodies (Glycoproteins)
    容量(メートル法)使用可能250 μL
    ウェルデザインC96
    アレイ8 x 12
    バーコードNo Barcode
    Clear
    フォーマットStandard
    材料Polystyrene
    ウェル数96
    無菌性Non-sterile
    表面処理MaxiSorp
    ウェル形状Round, C Bottom
    Unit SizeCase of 60

    よくあるご質問(FAQ)

    For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

    For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

    What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

    We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
    One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

    Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

    Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
    Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

    For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

    The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
    - Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
    - Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
    - "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
    - StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

    What is the difference between certified and non-certified MaxiSorp plates and modules?

    Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.