Ion Xpress™ Plus Fragment Library Kit
Ion Xpress™ Plus Fragment Library Kit
Ion Torrent™

Ion Xpress™ Plus Fragment Library Kit

The Ion Xpress™ Plus Fragment Library Kit provides a rapid and flexible enzymatic-based library construction methodology for the Personal Genome詳細を見る
製品番号(カタログ番号)数量
447126910 Reactions
製品番号(カタログ番号) 4471269
価格(JPY)
140,000
Each
お問い合わせください ›
数量:
10 Reactions

The Ion Xpress™ Plus Fragment Library Kit provides a rapid and flexible enzymatic-based library construction methodology for the Personal Genome Machine™ sequencing system workflow. Employing enhanced proprietary Ion Shear™ DNA fragmentation chemistry, this revolutionary kit allows completion of library preparation in as little as 2 hours for gDNA and amplicon libraries, removing the need for a physical shearing device to save time and cost. With significantly higher yields and lower bias than other library construction techniques, superior coverage uniformity is attained with as little as 100 ng input DNA. In addition, highly efficient library construction enables the creation of 'amplification-free' libraries from 1 μg input material. This kit allows users to modulate an appropriate fragment insert size depending on desired read length and application.

The Ion Xpress™ Plus Fragment Library Kit contains sample preparation reagents for enzymatic shearing and library construction for up to 20 DNA libraries (depending on input DNA type) for semiconductor sequencing. Store components at -20°C.

The Ion Xpress™ Plus Fragment Library Kit offers you:

  • Superior coverage uniformity for diverse sample types using our proprietary Ion Shear™ Plus chemistry
  • Lower input requirement with as little as 100 ng starting material
  • Rapid and flexible workflow with Ion fragment libraries containing variable insert sizes in as fast as 2 hours
  • Significant cost savings by removing the need for ancillary shearing devices
  • Scalable methodology applicable to automated library preparation systems including the AB Library Builder™ System

A Single-Day Workflow: The Next Stage in a Sequencing Revolution

With a turnaround time of as little as 2 hours, the Ion Xpress™ Fragment Library Kit shortens the Ion sequencing workflow to a single workday, making comprehensive analyses of your sample(s) of interest possible in less time than ever before. Furthermore, Ion Xpress™ Plus fragment libraries exhibit greater coverage uniformity and higher recovery rates across diverse sample types than other library construction methodologies, so you can be confident of generating the best data in the shortest time.

Ion Torrent Sequencing Made Simpler, Faster, and More Affordable

Ion Shear™ Plus DNA fragmentation technology, included in the Ion Xpress™ Plus kit, obviates the need for costly physical shearing devices for most applications and requires as little as 100 ng of sample, accelerating your path to semiconductor sequencing. This flexible technology provides users the ability to adjust the resulting DNA fragment size to accommodate a range of sequencing read lengths depending on their project requirements. This technology is also amenable to automated library preparation systems such as the AB Library Builder™ System to provide quick answers when you need them most. Ion Shear™ Plus DNA fragmentation technology is not included in the Ion Plus kit. Use the Ion Plus kit if physical shearing methods are preferred.

研究用途にのみご使用ください。診断目的には使用できません。
仕様
使用対象(アプリケーション)配列
使用対象 (装置)Ion GeneStudio™ S5 Series Sequencer, Ion Chef™ System
高スループット適合性High-throughput Compatible, Multiplexing
ライブラリフラグメントライブラリ
反応数10
製品ラインIon Torrent, Ion Xpress
製品タイプPlus Fragment Library Kit
数量10 Reactions
サンプルタイプDNA
技術Post-Light™ Ion Semiconductor Sequencing
テンプレート適合性Genomic DNA
ワークフローステップライブラリ生成
フォーマットキット
Sequencing TypeゲノムおよびDNAシーケンシング
Unit SizeEach
組成および保存条件
Ion Plus Fragment Library Kit & Ion Shear™ Plus Reagents Kit, –°C to –10°C

よくあるご質問(FAQ)

DNAライブラリーを作製する場合、RNAを取り除く必要がありますか?

クォリティの高い RNA-free DNAが必要になります。input DNAのクォリティが最終的なライブラリーのクォリティに大きな影響を及ぼします。DNA抽出に使用したキットにRNase I処理が無かった場合、Ion Xpress Plus gDNA Fragment Library Preparation User GuideのAppendix Cを参照し、input DNAの質やサイズ、Rnase処理に関する記載をご覧ください。

Ion Xpress Barcode Adapters kitを用いて何ライブラリー作製することができますか?

Ion Xpress Barcode Adapters kitは、96セット (Cat. No. 4474517)あるいは16セット (Cat. Nos.4471250, 4474009, 4474518, 4474519, 4474520 or 4474521)での購入が可能です。それぞれのbarcode kitは、100 ngインプットの場合、一種類のbarcodeあたり ≤ 10ライブラリー (全体で、10 x 16ライブラリー、あるいは、10 x 96ライブラリー) 作製することができ、1 μgインプットの場合、一種類のbarcodeあたり2ライブラリー作製することができます。

Ion AおよびP1アダプターの配列はどのようになっていますか?

Ion AおよびP1アダプターの配列はIon Xpress Plus gDNA Fragment Library Preparation User Guide (Pub. No. 4471989)のAppendixをご参照ください。

Ion Xpress Plus gDNA Fragment Library Preparation User Guide (Pub. No. 4471989)に記載があるrecommended median insert sizeとrecommended median library sizeの違いは何ですか?

recommended median insert sizeとはIon AおよびP1アダプターを含まないターゲットDNA断片のみの長さになります。recommended median library sizeとはターゲットDNA断片の長さ + Ion AおよびP1アダプターを含む最終的なライブラリーの全長になります。Ion AおよびP1アダプターを使用している場合、ターゲットDNA断片の長さに ~70 bpを足し、Barcode付きA adapterおよびP1アダプターを使用している場合、~80 bpを足した長さが最終的なライブラリーの全長になります。

Ion Xpress Plus Fragment Library Kit (Cat. No. 4471269)またはIon Plus Fragment Library Kit (Cat. No. 4471252)から何ライブラリー作製することができますか?

Ion Plus Fragment Library KitとIon Xpress Plus Fragment Library Kitでは、100 ng DNAインプットで≤ 20ライブラリー、1 μg DNAインプットで≤ 10ライブラリー作製することができます。