Ion Total RNA-Seq Kit v2
Ion Total RNA-Seq Kit v2
Ion Torrent™

Ion Total RNA-Seq Kit v2

The Ion Total RNA-Seq Kit v2 includes the reagents needed to prepare representative cDNA libraries for strand-specific RNA sequencing on詳細を見る
製品番号(カタログ番号)反応数
447593612 Reactions
447978948 Reactions
製品番号(カタログ番号) 4475936
価格(JPY)
203,400
Each
お問い合わせください ›
反応数:
12 Reactions
The Ion Total RNA-Seq Kit v2 includes the reagents needed to prepare representative cDNA libraries for strand-specific RNA sequencing on the Ion GeneStudio S5, Ion Proton, or the Ion Personal Genome Machine (PGM) systems. The Ion GeneStudio S5 and Ion Proton systems are ideally suited for sequencing the whole transcriptome (ribosomal RNA depleted or polyA), while the Ion GeneStudio S5 and Ion PGM systems are suitable for viral and bacterial transcriptomes. Version 2 of the Ion Total RNA-Seq Kit is an improvement over the first generation kit. Magnetic bead-based purification replaces all of the filter cleanup steps and the total reaction time has been reduced to 6 hours.

Additional Features of the New Ion Total RNA-Seq Kit v2:

• Greater accuracy—SuperScript VILO and Platinum PCR SuperMix High Fidelity added for highest template fidelity
• Barcode compatible—works with Ion Xpress RNA-Seq Barcode 01-16 Kit for multiplexing
• Automation friendly—magnetic bead-based purification simplifies automation of library construction

As with the previous kit, the Ion Total RNA-Seq Kit v2:

• Preserves strand information—all mapped reads are aligned in the direction of transcription relative to the chromosomal strand
• Allows you to analyze different types of RNA—supports rRNA depleted total RNA, and poly(A) RNA

The Ion Total RNA-Seq Kit v2 is designed to make cDNA library preparation fast and flexible. It can be used to generate a representative cDNA library, flanked by specific sequences necessary for sequencing, from any type of RNA sample.

Designed as a complete solution with a common workflow, the Ion Total RNA-Seq Kit v2 combines optimized reagents and protocols for discovery of coding RNA, noncoding RNA, and alternative splice variants.

Whole transcriptome analysis
The whole transcriptome protocol enables construction of strand-specific libraries in approximately 5 hours. Starting with as little as 100 ng of total RNA, construct a library from 1 ng of poly(A) RNA or 25 ng of rRNA-depleted RNA following the RNA enrichment and library generation protocols provided in the manual. Because the libraries are not limited to cDNA derived only from poly(A) RNA, Ion Total RNA-Seq Kit libraries support a more thorough investigation of transcriptome complexity, capable of characterizing known and undocumented transcripts, including alternative splice variants, fusion transcripts, and SNPs.

Preserve strand information
Unlike methods that ligate adapters to double-stranded cDNA, the Ion Total RNA-Seq Kit v2 utilizes proprietary Ambion technology to attach the adapters in a directional manner that preserves strand information in the resulting libraries. In addition, both the 3' and 5' adapters are attached simultaneously, reducing ligation and clean-up steps.

Preserving strand orientation during library construction helps enable more accurate determination of the structure and expression level of transcripts, and can aid in the discovery of novel transcription regions from both the positive and negative genomic strands.

The Ion Total RNA-Seq Kit v2 is designed to create RNA libraries from up to 48 samples for whole transcriptome sequencing on the Ion GeneStudio S5, Ion Proton, or Ion PGM systems.
For Research Use Only. Not for use in diagnostic procedures.
仕様
使用対象 (装置)Ion GeneStudio™ S5, Ion PGM™, Ion Proton™ Systems
ライブラリcDNAライブラリ
反応数12 Reactions
製品ラインIon Torrent
数量12 reactions
シーケンスタイプトランスクリプトームシーケンシング
出発物質量For RNA (rRNA-depleted): 1-100 ng mRNA
For whole transcriptome: ≥100 ng total RNA
ワークフローステップNGS Library Preparation
サンプルタイプRNA
Unit SizeEach
組成および保存条件
Ion RNA-Seq Core Kit v2

Store at -20°C to room temperature:

2 x 1.75 mL Nuclease-free Water

Store at -20°C:
1 x 20 μL 10X RNase III Reaction Buffer
1 x 20 μL RNase III
1 x 40 μL Hybridization Solution
1 x 150 μL 2X Ligation Buffer
1 x 30 μL Ligation Enzyme Mix
1 x 30 μL 2.5 mM dNTP Mix
1 x 56 μL 10X SuperScript™ III Enzyme Mix
1 x 900 μL Platinum™ PCR SuperMix High Fidelity
1 x 50 μL WT Control RNA (1 μg/μL HeLa total RNA)
1 x 10 μL Small RNA Control (1 μg/μL human placenta total RNA)
1 x 10 μL Small RNA Control (1 μg/μL human placenta total RNA)

Ion RNA-Seq Primer Set v2 (Cat. No. 4474810)

Store at -20°C:

1 x 30 μL Ion Adaptor Mix v2
1 x 104 μL Ion RT Primer v2
1 x 20 μL Ion 5' PCR Primer v2
1 x 20 μL Ion 3' PCR Primer v2

よくあるご質問(FAQ)

Ion RNA-Seqのsmall RNAライブラリーを作製で、エンリッチしたsmall RNAサンプルをAgilent Small RNA KitおよびAgilent 2100 Bioanalyzerを用いて測定したところ、予想よりはるかに多量のsmall RNAが見られた。これは問題でしょうか?

分解されたtotal RNAからsmall RNAをエンリッチした可能性が高いです。small RNAはサイズの違いによってエンリッチを行うため、大きいRNA(rRNA、tRNA)などが分解されているとsmall RNA画分と共に回収されます。total RNAのクォリティをAgilent 2100 Bioanalyzerを用いて測定することをお勧めします。

Ion Xpress RNA-Seq Barcodes 1-16 (Cat. No. 4475485)の配列を得ることは可能でしょうか?

Ion Xpress RNA-Seq Barcode 1-16の配列は、DNA用のIon Xpress Barcode Adapter 1-16と同じです。配列は、Torrent BrowserのReferencesから参照することが可能です。

ウィルスRNAと哺乳類RNAが混ざっているサンプルを使用してIon RNA-Seqライブラリーを作製したらどうなるでしょうか?ウィルスRNAをターゲットとしている場合、このようなラブラリーをシーケンスに用いることができますか?

このような場合、シーケンスの大半がウィルス以外のものになりますので、オフターゲットの割合が非常に多くなります。可能ならば、サンプル調製の前にRNAを分離させることをお勧めします

small RNAとwhole transcriptomeのライブラリーを作製するのには、それぞれ別のキットが必要でしょうか?

必要ありません。Ion Total RNA-Seq Kit v2 (Cat. Nos. 4475936 & 4479789)一つで、whole transcriptomeと small RNAのライブラリーを両方作製することができます

What is an indicator of a successful RNA library?

Generally, a successful Ion RNA-Seq library will be within the recommended size range for sequencing on the Ion PGM or Proton systems and the sequencing data will have a high (or expected) percentage of on-target reads.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.