Clear Flat-Bottom Immuno Nonsterile 96-Well Plates
Clear Flat-Bottom Immuno Nonsterile 96-Well Plates
Clear Flat-Bottom Immuno Nonsterile 96-Well Plates
Clear Flat-Bottom Immuno Nonsterile 96-Well Plates
Clear Flat-Bottom Immuno Nonsterile 96-Well Plates
Thermo Scientific™

Clear Flat-Bottom Immuno Nonsterile 96-Well Plates

Choose from four binding surfaces of these 96-well plates for reliable and reproducible results in colormetric assays.
製品番号(カタログ番号)表面処理認証済み容量(メートル法)使用可能バーコード
456529PolySorpNo350 μLNo Barcode
3355Immulon 1 BNo230 μLNo Barcode
3455Immulon 2 HBNo280 μLNo Barcode
3855Immulon 4 HBXNo280 μLNo Barcode
439454MaxiSorpYes350 μLNo Barcode
442404MaxiSorpNo350 μLNo Barcode
456537MaxiSorpYes350 μLNo Barcode
460984MaxiSorpYes350 μLIncludes Barcode
467320MediSorpYes350 μLNo Barcode
467340MultiSorpNo350 μLNo Barcode
475094PolySorpNo350 μLNo Barcode
9502227Universal BindingNo330 μLNo Barcode
95029330Enhanced BindingYes330 μLNo Barcode
製品番号(カタログ番号) 456529
価格(JPY)
93,880
Case of 180
お問い合わせください ›
表面処理:
PolySorp
認証済み:
No
容量(メートル法)使用可能:
350 μL
バーコード:
No Barcode
定量・定性固相イムノアッセイに最適な Thermo Scientific™ Nunc™、Immulon™ および Microtiter™ クリアプレートを取りそろえたThermo Scientific™ クリア平底イムノ未滅菌 96 ウェルプレートは比色法において信頼性と再現性のある結果を得るため、四つの結合表面から選択することができます。

96 ウェルソリッドプレート:

  • 透明ポリスチレン
  • 最適な結合能を得るため、四つの表面から選択可能
  • 行と列には英数字を刻印

表面:

  • Thermo Scientific™ PolySorp™、Immulon™ 1B およびユニバーサルバインド (UB) は、疎水性分子の吸着に使用します。
  • Thermo Scientific™ Medisorp™ および Immulon 2HB は弱親水性で、多様な生体分子に結合します。
  • Thermo Scientific™ MaxiSorp™、Immulon 4 HBX およびエンハンストバインド (EB) は親水性で、抗体を用いたサンドイッチ法に最適です。
  • Thermo Scientific™ MultiSorp™ は親水性が強く、グリカンおよび水溶性タンパク質の吸着に最適です。

オーダー情報:

販売状況は国によって異なりますのでご注意ください。 467320、456537、460984、439454 には証明書が含まれています。

仕様
結合タイプAdsorption
認証済みNo
検出法Colorimetric
蓋なし
箱あたりの入数180
パックあたり入数10
パッケージ180ケース
プレートブロッキングなし
製品タイプマイクロプレート
数量180/Cs.
標的分子Lipids
容量(メートル法)使用可能350 μL
アレイ8 x 12
バーコードNo Barcode
Clear
フォーマットStandard
材料Polystyrene
ウェル数96
無菌性Non-sterile
表面処理PolySorp
容量(メートル法)ウェル400 μL
ウェル形状Flat Bottom (F-well)
Unit SizeCase of 180

よくあるご質問(FAQ)

For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

Which Nunc immunodiagnostic passive surface should I choose: PolySorp, MediSorp, MaxiSorp, or MultiSorp?

Our passive immunodiagnostic surfaces are based on a series of treatments that modify the polystyrene surface to different final levels of hydrophilicity. Selection of one of these surfaces for ELISA development should be based on the characteristics of the biomolecule you seek to immobilize. PolySorp is fairly hydrophobic and should be used for biomolecules that have hydrophobic domains, e.g., lipids, lipoproteins, and large proteins. MediSorp is slightly hydrophilic and can be used for biomolecules with hydrophilic and hydrophobic properties, e.g., medium-to-large proteins such as albumin, or amphiphilic biomolecules such as LPS. MaxiSorp is quite hydrophilic, optimized for binding of IgG (and any other molecule with similar characteristics) and thus is a popular choice for sandwich ELISA and similar protocols. MultiSorp is very hydrophilic, and in turn will immobilize very hydrophilic biomolecules such as glycoproteins. Some optimization will always be necessary, and in many cases screening for binding optimization may involve a few surface types.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.

What is the difference between a certified and an uncertified immunodiagnostic plate, e.g., Cat. No. 439454 vs. 442404?

There is no difference in the manufacturing process. Certified plates are performance tested (using an antibody binding protocol) during quality control, whereas uncertified plates are not. This test is expensive for us to perform, so we offer the uncertified version at cost savings customers for whom antibody binding testing results are not critical.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.