Clear Flat-Bottom Immuno Nonsterile 96-Well Plates
Clear Flat-Bottom Immuno Nonsterile 96-Well Plates
実際の製品は異なる場合があります
Thermo Scientific™

Clear Flat-Bottom Immuno Nonsterile 96-Well Plates

Choose from four binding surfaces of these 96-well plates for reliable and reproducible results in colormetric assays.
製品番号(カタログ番号)表面処理認証済み容量(メートル法)使用可能バーコード
460984MaxiSorpYes350 μLIncludes Barcode
3355Immulon 1 BNo230 μLNo Barcode
3455Immulon 2 HBNo280 μLNo Barcode
3855Immulon 4 HBXNo280 μLNo Barcode
439454MaxiSorpYes350 μLNo Barcode
442404MaxiSorpNo350 μLNo Barcode
456529PolySorpNo350 μLNo Barcode
456537MaxiSorpYes350 μLNo Barcode
467320MediSorpYes350 μLNo Barcode
467340MultiSorpNo350 μLNo Barcode
475094PolySorpNo350 μLNo Barcode
9502227Universal BindingNo330 μLNo Barcode
95029330Enhanced BindingYes330 μLNo Barcode
製品番号(カタログ番号) 460984
価格(JPY)
145,860
Case of 180
お問い合わせください ›
表面処理:
MaxiSorp
認証済み:
Yes
容量(メートル法)使用可能:
350 μL
バーコード:
Includes Barcode
定量・定性固相イムノアッセイに最適な Thermo Scientific™ Nunc™、Immulon™ および Microtiter™ クリアプレートを取りそろえたThermo Scientific™ クリア平底イムノ未滅菌 96 ウェルプレートは比色法において信頼性と再現性のある結果を得るため、四つの結合表面から選択することができます。

96 ウェルソリッドプレート:

  • 透明ポリスチレン
  • 最適な結合能を得るため、四つの表面から選択可能
  • 行と列には英数字を刻印

表面:

  • Thermo Scientific™ PolySorp™、Immulon™ 1B およびユニバーサルバインド (UB) は、疎水性分子の吸着に使用します。
  • Thermo Scientific™ Medisorp™ および Immulon 2HB は弱親水性で、多様な生体分子に結合します。
  • Thermo Scientific™ MaxiSorp™、Immulon 4 HBX およびエンハンストバインド (EB) は親水性で、抗体を用いたサンドイッチ法に最適です。
  • Thermo Scientific™ MultiSorp™ は親水性が強く、グリカンおよび水溶性タンパク質の吸着に最適です。

オーダー情報:

販売状況は国によって異なりますのでご注意ください。 467320、456537、460984、439454 には証明書が含まれています。

仕様
結合特性Hydrophilic
結合タイプAdsorption
認証済みYes
検出法Colorimetric
蓋なし
箱あたりの入数180
パックあたり入数180
パッケージ180ケース
プレートブロッキングなし
製品タイプマイクロプレート
標的分子Antibodies (Glycoproteins)
容量(メートル法)使用可能350 μL
アレイ8 x 12
バーコードIncludes Barcode
Clear
フォーマットStandard
材料Polystyrene
ウェル数96
無菌性Non-sterile
表面処理MaxiSorp
容量(メートル法)ウェル400 μL
ウェル形状Round, Flat Bottom (F-well)
Unit SizeCase of 180

よくあるご質問(FAQ)

For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.