Immuno Clear Standard Modules
Immuno Clear Standard Modules
Immuno Clear Standard Modules
Immuno Clear Standard Modules
Immuno Clear Standard Modules
Thermo Scientific™

Immuno Clear Standard Modules

Perform applications that deliver well-to-well reproducibility with these immuno clear standard modules. Manufactured to fit standard equipment.
製品番号(カタログ番号)表面処理容量(メートル法)使用可能ウェル形状ウェルデザイン
469914MaxiSorp350 μLRound, Flat Bottom (F-well)F16 (2x8 wells)
441653MaxiSorp250 μLRound, C BottomC8
444865PolySorp250 μLRound, C BottomC8
445101MaxiSorp250 μLRound, C BottomC8
467120MediSorp350 μLRound, Flat Bottom (F-well)F8
467140MultiSorp350 μLRound, Flat Bottom (F-well)F8
467466MaxiSorp350 μLRound, Flat Bottom (F-well)F16 (2x8 wells)
467679PolySorp350 μLRound, Flat Bottom (F-well)F16
468667MaxiSorp350 μLRound, Flat Bottom (F-well)F8
469078PolySorp350 μLRound, Flat Bottom (F-well)F8
469264Hydrophilic250 μLRoundU16
469922PolySorp350 μLRound, Flat Bottom (F-well)F16 (2x8 wells)
469949MaxiSorp350 μLRound, Flat Bottom (F-well)F8
469957PolySorp350 μLRound, Flat Bottom (F-well)F8
473709MaxiSorp250 μLRound, C BottomC12
473717PolySorp250 μLRound, C BottomC12
475078MaxiSorp250 μLRoundU8
475086PolySorp250 μLRoundU8
6302Immulon 2 HB330 μLRound, Flat Bottom (F-well)F12
6309Immulon 2 HB330 μLRound, Flat Bottom (F-well)F12
6310Immulon 1 B330 μLRound, Flat Bottom (F-well)F12
6405Immulon 4 HBX330 μLRound, Flat Bottom (F-well)F12
95029100Enhanced Binding350 μLRound, Flat Bottom (F-well)F8
6301TS1
または、製品番号6301
Immulon 1 B330 μLRound, Flat Bottom (F-well)F12
製品番号(カタログ番号) 469914
価格(JPY)
44,560
Case of 320
お問い合わせください ›
表面処理:
MaxiSorp
容量(メートル法)使用可能:
350 μL
ウェル形状:
Round, Flat Bottom (F-well)
ウェルデザイン:
F16 (2x8 wells)

Thermo Scientific™ イムノ透明モジュールは ELISA 法向けに開発された Nunc™、Immulon™ および Microtiter™ モジュールプレートで、ウェル間の再現性が必要なアプリケーションに適しています。標準的な機器に適合するように製造されたモジュールで、サンプル数が少ない場合に、モジュールの構成部分を柔軟に使用することができます。これらのモジュールは、業界最高レベルの品質規格と保証で実証されています。

特長:

  • さまざまなストリップ形状: 8 ウェルストリップ、12 ウェルストリップ、16 ウェルストリップ (8 ウェルが 2 列)
  • さまざまなウェル形状: 平底、C 底 (放射状エッジ)、U 型ウェル、スターウェル (ウェルにフィンが備わっているため、表面積が増え、吸着能が高まります)
  • アッセイの性能を最大限に高めるさまざまな表面
  • 逆さにしてもは脱落しないモジュール
  • フタの向きを示すマーク付きの積み重ね可能なフレーム
  • ポリエチレン製フレームに収まったポリスチレン製ウェル
  • 外径: 寸法128 × 86 mm
  • 表面処理の選択肢:

  • Thermo Scientific™ PolySorp™、Immulon™ 1B およびユニバーサルバインド (UB) は、疎水性分子の吸着に使用します。
  • Thermo Scientific™ Medisorp™ および Immulon 2HB は弱親水性で、多様な生体分子に結合します。
  • Thermo Scientific™ MaxiSorp™、Immulon 4 HBX およびエンハンストバインド (EB) は親水性で、抗体を用いたサンドイッチ法に最適です。
  • Thermo Scientific™ MultiSorp™ は親水性が高く、グリカンおよび水溶性タンパク質の吸着に最適です。
  • ご注文情報:

    モジュールは自立型です。ご注文番号95029440 および 464394 は保証書付きです。フレームとモジュールは個別に購入できます。密封テープおよびストリップキャップをご用意しています。ご要望に応じて色で識別されたモジュールもご利用できます。詳細は、カスタマーサービスまたは販売代理店にお問い合わせください。

    限定的保証期間: 当社の販売契約条件で規定されている保証要件および例外事項に従い、この製品は出荷日から90日間保証されます。

    内部研究への使用制限に関する免責条項: この製品の内部研究目的の限定使用に関する購入者への制限は、この条件に関連したウェブページの製品には適用されません。

    仕様
    結合特性Hydrophobic
    結合タイプAdsorption
    分解No
    認証/コンプライアンスCertified for adsorption of IgG; CV of <5% between wells
    認証済みYes
    検出法Colorimetric
    蓋なし
    箱あたりの入数320
    パックあたり入数80
    パッケージ80 Pk., 320 Cases
    プレートブロッキングなし
    製品タイプMicroplate Strip
    数量320/Cs.
    標的分子Lipids
    容量(メートル法)使用可能350 μL
    ウェルデザインF16 (2x8 wells)
    アレイ2 x 8
    Clear
    フォーマットStrip Plate
    材料Polystyrene
    ウェル数16
    表面処理MaxiSorp
    容量(メートル法)ウェル400 μL
    ウェル形状Round, Flat Bottom (F-well)
    Unit SizeCase of 320

    よくあるご質問(FAQ)

    What frames do you recommend for your Immuno Clear Standard Modules?

    We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

    What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

    We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
    One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

    Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

    Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
    Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

    Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

    Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
    8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

    For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

    The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
    - Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
    - Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
    - "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
    - StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.