The Thermo Scientific™ 5014iQ Beta Attenuation Monitor is an automated ambient particulate measurement utilizing beta attenuation.
製品番号(カタログ番号)測定範囲
5014IQ
または、製品番号5014iQ
0 to 10,000 μg/m3
製品番号(カタログ番号) 5014IQ
または、製品番号5014iQ
価格(JPY)
-
お問い合わせください ›
測定範囲:
0 to 10,000 μg/m3

The Thermo Scientific™ 5014iQ Beta Attenuation Monitor is designed for monitoring PM-2.5, PM-10, PM-1, and TSP in ambient air. The PM samples are collected using a filter tape which automatically advances to a clean spot reducing the requirement for attended operation. The filter tape advance is controlled by user-defined parameters such as mass accumulation limits, flow rates, and advances in a continuous pattern to help mitigate particle loss.

The instrument monitors the sample conditions and adjusts the control system to heat only, when necessary, eliminates moisture effects, and ensures that volatile aerosols remain intact for accurate measurement.

This state-of-the-art monitor features:

  • US EPA approved PM-10 (EQPM-1102-150) and PM-2.5
  • (EQPM-0609-183) equivalent monitor
  • Continuous measurement
  • Low detection limit, high accuracy, and resolution
  • Enhanced user interface and ePort communication software
  • Enhanced ethernet connectivity
  • Long-term unattended operation
  • Remote data access
仕様
確度±5% using SI-traceable mass foil set (for mass measurement)
認証/コンプライアンスU.S. EPA PM-2.5 equivalent monitor (EQPM-1609-183)
通信プロトコルMODBUS, TCP/IP, Gesytec (Bayern-Hessen), streaming data and NTP (Network Time Protocol) protocols. Simultaneous connections from different locations over Ethernet
濃度測定範囲60 to 3,600 seconds and 24-hour
データ平均化Every 1 second
奥行き(ヤードポンド法)21.16 in.
奥行き(メートル法)53.8 cm
概要5014iQ Beta Attenuation Monitor
電気的要件Designed to meet CE: EN61326: 1997 + A1: 1998 + A2: 2001 + A3: 2003, EN61010-1 UL: 61010-1: 2004; CSA: C22.2 No. 61010-1: 2004; FCC: Part 15 Subpart B, Class B, UKCA
高さ(ヤードポンド法)12.2 in.
高さ(メートル法)31 cm
測定範囲0 to 10,000 μg/m3
出力
  • Standard ports 3 full-speed USB ports (one in front, two in rear) 1 gigabit ethernet port
  • Analog I/O (optional) 4 isolated voltage inputs 0–10 V 6 isolated analog voltages outputs, with 4 selectable ranges 6 isolated analog current outputs, with 2 selectable ranges
  • Digital I/O (optional) 16 digital inputs (TTL) 8 solenoid driver outputs,10 digital reed relay contact outputs
  • Serial ports (optional) 1 RS-232/485 port, 1 RS-485 external accessory port
精度±2.0 μg/m3, <80 μg/m3, 4–5 μg/m3 > 80 μg/m3 (24-hour average)
分解能0.1 μg/m3
サンプリングフローおよび制御
  • Sample flow precision: ±2% of measured value
  • Sample flow accuracy: <5% of measured value
ワット数
  • 100–240 VAC, 50–60 Hz recommended, 805 watts (115 V)
  • 880 watts maximum (220–240 V (instrument, heater & pump)
重量 (ヤードポンド法)< 55.1 lbs.
重量(メートル法)< 25 kg
幅(ヤードポンド法)16.73 in.
幅(メートル法)42.5 cm
流速1 m3/h (16.67 L/min) measured across an internal subsonic orifice, user selectable 14 to 20 lpm
測定されるガスCarbon-14 (C-14), < 3.7 MBq (<100 μCi)
温度(華氏)動作The temperature of sampled air may vary -30 to 50 °C. 5014iQ Monitor must be weather protected within range 4 to 40 °C, an optional complete outdoor enclosure provides complete weather protection