CaptureSelect™ CH1-XL RoboColumn™ Pre-packed Column
CaptureSelect™ CH1-XL RoboColumn™ Pre-packed Column
Thermo Scientific™

CaptureSelect™ CH1-XL RoboColumn™ Pre-packed Column

Thermo Scientific™ CaptureSelect™ RoboColumn™ small chromatography columns are used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.
製品番号(カタログ番号)容量(メートル法)
5943462200200 μL
5943462600600 μL
製品番号(カタログ番号) 5943462200
価格(JPY)
71,100
Each
お問い合わせください ›
容量(メートル法):
200 μL

CaptureSelect RoboColumn™ small chromatography columns are used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.

CaptureSelect CH1-XL Affinity Matrix recognizes the CH1 domain of human IgG antibodies, thereby enabling purification of all Fab fragments, independent of the light-chain type (kappa or lambda) and without binding of over-expressed light chain and light-chain dimers. In addition, it can be used for the purification of human IgGs from all four subclasses (1, 2, 3, and 4).

Features of this affinity matrix include:

  • Platform approach for purification of high quality and correctly assembled human Fab fragments
  • No co-purification of over-expressed free light chains due to selectivity for the CH1 domain
  • Elution possible at pH 4.0–4.5 with 50 mM acetate buffer
  • Caustic cleaning with up to 50 mM NaOH
  • Excellent scalability
  • No cross-binding to bovine IgG, therefore presence of fetal bovine serum is not a problem
  • Non-animal-derived

Free of animal components

CaptureSelect products contain affinity ligands based on recombinant single-domain antibody fragments (VHH) created by a proprietary technology. The VHH affinity ligand is a 12 to 15 kDa fragment comprising the three complementarity-determining regions (CDRs) that form the antigen-binding domain, efficiently produced in the yeast Saccharomyces cerevisiae by a production process free of any animal components (Animal Origin-Free).

Characteristics

  • Column size: 200 μL and 600 μL, 1 strip, 8 columns (8-row)
  • Column dimension: 200 μL: 5 x 10 mm
  • Column dimension: 600 μL: 5 x 30 mm
  • Matrix: agarose based, epoxide-activated
  • Average particle size: 65 ± 10 μm
  • Ligand: CaptureSelect CH1-XL affinity ligand
  • Ligand coupling: epoxide coupling
  • Binding capacity: >15 mg/mL human Fab fragment depending on flow rate, column height, contact time. For humanized Fabs, lower capacities may be observed.
  • Elution conditions: 100 mM glycine buffer, pH 3.0; 50 mM acetate buffer, pH 4.0–4.5
  • Formulation buffer: 20% (v/v) ethanol
  • Operating pressure: 2 bar (maximum)
  • Flow rate: 16–150 cm/h

RoboColumn is a trademark of Repligen.

For Research Use Only. Not for use in diagnostic procedures.
仕様
結合能>15 mg/mL human Fab fragment
カラムタイプRoboColumn
直径(メートル法)5 mm
流速16 to 150 cm/hr.
使用対象(アプリケーション)Chromatography
フォーマット8-well Strips
長さ(メートル法)10 mm
リガンドタイプCH1-XL affinity ligand
マトリックスAgarose-based, epoxide-activated
最大動作圧力2 bar
数量200 μL
出荷条件Room temperature, or on wet ice
固定相CH1-XL affinity ligand on agarose bead
容量(メートル法)200 μL
粒子径65 ±10 μm
製品ラインCaptureSelect
タイプColumn
Unit SizeEach
組成および保存条件
Store in refrigerator (2°C to 8°C)