高速、簡便、堅牢な、再現性の高いタンパク質消化を実行し、in-solution 技法の問題をなくします。
製品番号(カタログ番号)フォーマットタイプ内容
60113-101Soluble TrypsinSoluble Trypsin KitSoluble Trypsin, Buffer, Collection Plate
60109-101Resin in Pre-filled PCR TubesTrypsin KitResin, Collection Plate
60109-101-LPHResin in Pre-filled PCR TubesTrypsin KitLow pH Resin, Collection Plate
60109-103Resin in Pre-filled PCR TubesTrypsin KitResin, Collection Plate, SOLAμ SPE Plate
60109-102Resin in Pre-filled PCR TubesTrypsin KitResin, Collection Plate, Filter Plate
60109-101-BBulk Non-magnetic ResinTrypsin KitResin, Buffer
60109-101-MBBulk Magnetic ResinTrypsin KitResin, Buffer
60109-102-BBulk Non-magnetic ResinTrypsin KitResin, Buffer, Collection Plate, Filter Plate
60109-102-MBBulk Magnetic ResinTrypsin KitResin, Buffer, Collection Plate, Filter Plate
60109-103-BBulk Non-magnetic ResinTrypsin KitResin, Buffer, Collection Plate, SOLAμ SPE Plate
60109-103-MBBulk Magnetic ResinTrypsin KitResin, Buffer, Collection Plate, SOLAμ SPE Plate
60113-101-10PKSoluble TrypsinSoluble Trypsin Kit - 10 Pk.Soluble Trypsin, Buffer, Collection Plate
製品番号(カタログ番号) 60113-101
価格(JPY)
-
見積もりを依頼する
フォーマット:
Soluble Trypsin
タイプ:
Soluble Trypsin Kit
内容:
Soluble Trypsin, Buffer, Collection Plate
Scientific™ SMART Digest™ キットによるタンパク質消化物から、高品質な分析結果を得ることができます。バイオ医薬品研究のサンプル調製を大幅に進化させるこのキットは、自動化に対応したフォーマットで、高再現性、高感度、および品質の高いデータにより、高速かつ簡便なタンパク質消化を提供します。再現性がなく低感度で、自動化未対応のため時間のかかる現在の in-solution タンパク質消化技術を、SMART Digest キットが大幅に進化させます。
簡単で使いやすい
  • サンプル処理の速度を大幅に向上
  • 3 ステップのサンプル調製
  • プロトコル全体の自動化が容易で高スループット処理に対応
信頼できる結果
  • 従来のプロトコルよりも高い再現性
  • 高感度
  • データの高い確度
サンプル調製時間を大幅に削減
in-solution 消化が最大 24 時間かかるのに対して、本キットは、通常 60 分未満で完了します (サンプルの複雑さにより異なります)。

幅広いシーケンス範囲
アルキル化手順、トリプシンの不在の低減と排除により、幅広いシーケンス範囲を実現しました。化学物質の使用数の削減、最終サンプル中のトリプシンの存在、翻訳後修飾 (PTM) の低減により、LC-MS 分析中の信号の抑制を緩和します。

SOLAµ SPE プレートとの組み合わせによる脱塩
Thermo Scientific™ SOLAµ™ SPE 固相抽出プレートは、SMART Digest 脱塩用に併用すると、高速で使いやすく、堅牢かつ自動化が容易な生体高分子分析用サンプル調製ソリューションを実現できます。

保証期間: 当社の販売契約条件で規定されている保証要件および例外事項に従い、この製品は出荷日から90日間保証されます。

内部研究への使用制限に関する免責条項: この製品の内部研究目的の限定使用に関する購入者への制限は、この条件に関連したウェブページの製品には適用されません。

仕様
概要SMART Digest Trypsin Kit, Soluble
使用対象(アプリケーション)Peptide Mapping
内容Soluble Trypsin, Buffer, Collection Plate
CaptureNone
CleavageC-terminal side of lysine and arginine amino acids
酵素Trypsin
フォーマットSoluble Trypsin
製品ラインSMART Digest
タイプSoluble Trypsin Kit
Unit SizeEach

よくあるご質問(FAQ)

Can I use the SMART Digest Soluble Trypsin Kit with filter-aided sample preparation (FASP)?

Yes, we recommend the following protocol, which can be optimized as needed:
1. Rinse a Fisher Scientific Vivacon 500, 30kDa MWCO filter (Cat. No. 14558347) to remove trace amounts of glycerin using a fill volume of water. Decant the filtrate and collection vessel. The filter is now ready for use. If you do not want to use the Vivacon filter immediately, then store the pre-rinsed device in the refrigerator with water or buffer covering the membrane surface. Do not allow the membrane to dry out.
2. Dilute sample water to a total volume of 150 µL on the filter.
3. Centrifuge 14,000 RPM for 15 minutes and discard the flow-through.
4. Add 150 µL water.
5. Centrifuge 14,000 RPM for 15 minutes and discard the flow-through.
6. Add 200 µL of SMART Digest buffer.
7. Change the collection vial and add 5 µL of the SMART Digest soluble enzyme to the filter.
8. Parafilm the filters to prevent evaporation of sample during digestion. Incubate the units in a heated bath at 70°C for 60 - 90 minutes.
9. Optional: As needed, add DTT (3 µL of 50 mM DTT), heat at 37°C and incubate for 30 minutes. Alkylate as needed (using 3 µL of 150 mM alkylating reagent).
10. After incubation, add 2 µL of 1% trifluoroacetic acid to the filter. Mix for 1 minute.
11. Centrifuge the filter units at 14,000 RPM for 10 min.
12. As needed, measure protein concentration using a Thermo Scientific NanoDrop Spectrophotometer, or similar procedure.

What is the best way to automate my workflow with the SMART Digest Soluble Trypsin Kit?

To automate the SMART Digest Soluble Trypsin Kit workflow, we recommend using deepwell plates with Sepra Seals, or PCR plates with iron-on seals in combination with an automated liquid handling platform. Any heating unit with a heated lid, capable of providing uniform heating at 70°C may be used.

Can I use chaotropes with the SMART Digest Soluble Trypsin Kit?

The kit is compatible with up to 1M urea, but incompatible with most concentrations of guanidine.

Can I use surfactants with the SMART Digest Soluble Trypsin Kit?

The kit is compatible with many surfactants including OGS, CHAPS, Nonidet, and NP-40.

Does digestion at high temperatures using the SMART Digest Soluble Trypsin Kit result in an increase in chemical modifications?

Thus far, studies have shown that by accelerating the reaction and minimizing the reaction time, fewer chemical modifications are observed in comparison to protocols utilizing elongated digestion times at lower temperatures. For more details, refer to the application note titled 'SMART Digest Compared to Classic In-Solution Digestion of Rituximab for In-Depth Peptide Mapping Characterization'.