Conduct quantitative and qualitative immunoassays like ELISA and binding assays with these white, 96-well immuno plates.
製品番号(カタログ番号)ウェル形状表面処理容量(メートル法)使用可能
7571Round, Flat Bottom (F-well)Microlite 1+280 μL
436110Round, Flat Bottom (F-well)MaxiSorp350 μL
436111Round, Flat Bottom (F-well)PolySorp350 μL
7572Round, Flat Bottom (F-well)Microlite 2+280 μL
7705Round, Flat Bottom (F-well)Microfluor 1280 μL
7905Round, Flat Bottom (F-well)Microfluor 2280 μL
9502887Round, Flat Bottom (F-well)Universal Binding330 μL
製品番号(カタログ番号) 7571
価格(JPY)
24,340
온라인 행사
Ends: 27-Mar-2026
30,420
割引額 6,080 (20%)
Case of 50
お問い合わせください ›
ウェル形状:
Round, Flat Bottom (F-well)
表面処理:
Microlite 1+
容量(メートル法)使用可能:
280 μL
Thermo Scientific™ 96 ウェルイムノプレート白は一般的な機器に適合し、ELISA や結合アッセイなどの定性および定量的免疫測定法に使用できます。これらのプレートは、最適な結果、ロット間の信頼性、およびウェル間の再現性を提供します。
特長
  • プレートは SBS 規格で、標準的な機器に適合
  • 平底または丸底のウェルから選択可
  • 3 つの表面タイプから選択でき、最適な結合を提供
  • 保証された結合の均一性および再現性
  • 表面処理の選択

  • 疎水性分子の吸着に適したThermo Scientific™ PolySorp™、Microfluor™ 1、Microlite™ 1+ およびユニバーサルバインド (UB)
  • Thermo Scientific™ MaxiSorp™ は、親水性で抗体サンドイッチ法に最適です
  • Thermo Scientific™ Microfluor 2 および Microlite 2+ は弱親水性で、さまざまな生体高分子を結合します。
  • 白色:

  • 最大限の反射を提供
  • 最小限の自己蛍光および自己発光
  • 互換性:

    Thermo Scientific™ MicroWell™ プレート用フタ、シーリングテープ、および通気性メンブレン

    ご注文情報:

    購入可能なモデルは国によって異なります。

    限定的保証期間: 当社の販売契約条件で規定されている保証要件および例外事項に従い、この製品は出荷日から90日間保証されます。

    内部研究への使用制限に関する免責条項: この製品の内部研究目的の限定使用に関する購入者への制限は、この条件に関連したウェブページの製品には適用されません。

    仕様
    結合特性Hydrophobic
    結合タイプAdsorption
    検出法Chemiluminescence
    使用対象(アプリケーション)Luminescence
    蓋付き
    箱あたりの入数50
    パックあたり入数10
    パッケージ50ケース
    プレートブロッキングなし
    製品タイプマイクロプレート
    標的分子Lipids
    容量(メートル法)使用可能280 μL
    アレイ8 x 12
    White
    フォーマットStandard
    材料Polystyrene
    ウェル数96
    表面処理Microlite 1+
    ウェル形状Round, Flat Bottom (F-well)
    Unit SizeCase of 50

    よくあるご質問(FAQ)

    For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

    For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

    Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

    Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
    8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

    For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

    The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
    - Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
    - Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
    - "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
    - StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

    Should I use an opaque black/white immuno plate, or an "optical-bottom" design?

    Opaque plates can only be used on “top reader” instruments, which detect (or, in fluorescence mode, excite and detect) from above the plate. Readers that detect from underneath the plate (or imaging systems) use optical-bottom plates, which have a black or white upper well structure and a transparent (polystyrene film or optical coverglass) bottom.

    Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.

    Why would I use a black or white (instead of clear) immuno plate?

    Black plates are often used in assays that make use of a fluorescent reporter because the opaque black surface effectively isolates the signal from each well in order to eliminate “crosstalk” or signal bleed. White plates also isolate well-to-well signals somewhat, but also provide a reflective background to direct luminescent output to the reader, and so often serve as a better choice to improve dynamic range from a luminescent reporter.

    Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.