Pierce™ High Capacity Endotoxin Removal Spin Columns, 1 mL
Pierce™ High Capacity Endotoxin Removal Spin Columns, 1 mL
Thermo Scientific™

Pierce™ High Capacity Endotoxin Removal Spin Columns, 1 mL

Thermo Scientific Pierce High Capacity Endotoxin Removal Resin binds to reduce endotoxin levels in protein samples by ≥99% in 1詳細を見る
製品番号(カタログ番号)数量
882765 Columns
8827725 Columns
製品番号(カタログ番号) 88276
価格(JPY)
47,100
Each
お問い合わせください ›
数量:
5 Columns
一括またはカスタム形式をリクエストする
Thermo Scientific Pierce High Capacity Endotoxin Removal Resin binds to reduce endotoxin levels in protein samples by ≥99% in 1 hour; with this spin cup format, protein recovery is ≥85%.

Features of High Capacity Endotoxin Removal Resin Spin Columns:

High capacity—bind up to 2,000,000 EU/mL to eliminate >99% of endotoxins
Selective—recover ≥85% of your protein sample
High performance—meets FDA guidelines by reducing final EU concentration to <5 EU/mL
Fast—our new spin cup format enables endotoxin depletion within 1 hour
Clean—single-use spin columns avoid cross contamination of samples
Optimized—spin cups are optimized for different sample volumes

The Pierce High Capacity Endotoxin Removal Resin combines porous cellulose beads and an FDA-approved food preservative, poly(ε-lysine), as an affinity ligand to selectively bind endotoxins. The modified polylysine affinity ligand eliminates the toxicity concerns associated with alternative technologies using polymixin B ligands and sodium deoxycholate buffers.

Requires:
Endotoxin-free water
Applications:

Eliminate endotoxins from protein or antibody samples prior to cell transfection or animal injection

The presence of endotoxins in biologically derived products prepared for research, vaccination, or therapeutic use is a major concern due to the diverse and potentially harmful biological response to these molecules. Endotoxin contamination in proteins purified from bacterial cultures is due to residual lipopolysaccharides (LPS) derived from the outer cell membrane of gram-negative bacteria such as E. coli. Endotoxin-contaminated protein samples transfected into cells or injected into an animal host can initiate a strong immune response resulting in a Systemic Inflammatory Response Syndrome (SIRS) and/or sepsis. Traditional endotoxin removal resins that use polymixin B and sodium deoxycholate to clear endotoxins from a sample also have the negative side effects of neurotoxicity and acute renal tubular necrosis.

Pierce High Capacity Endotoxin Removal Resin is a porous cellulose bead that has been surface-modified with covalently attached polylysine chains that have a high affinity for LPS but lacks the toxicity of other endotoxin-binding molecules. With a 2,000,000-EU/mL binding capacity, endotoxin levels can be reduced by 99% in samples containing initial endotoxin levels of 10,000 EU/mL. Typical protein samples processed with the High Capacity Endotoxin Removal Resin have a final endotoxin concentration below 5 EU/mL. This spin cup format is a fast, single-use method to remove endotoxins from protein samples in as little as 1 hour. The spin cups use a batch format to bind and remove endotoxins while allowing for >85% protein recovery.

One endotoxin unit/mL (EU/mL) equals approximately 0.1ng endotoxin/mL of solution.

More Product Data
Removing endotoxins using a spin-column format
Eliminate endotoxins from protein and antibody samples

Related Products
Pierce™ High Capacity Endotoxin Removal Resin
Pierce™ High Capacity Endotoxin Removal Spin Columns, 0.25 mL
Pierce™ High Capacity Endotoxin Removal Spin Columns, 0.5 mL
研究用途にのみご使用ください。診断目的には使用できません。
仕様
カラムタイプAffinity, Cellulose Resin
フォーマットSpin Column
組成22mL-capacity centrifuge columns containing 1mL resin
数量5 Columns
固定相Proprietary Ligand
ターゲットEndotoxin Removal
容量(メートル法)Up to 2,000,000 EU/mL
形状Liquid
製品ラインPierce
タイプスピンカラム
Unit SizeEach
組成および保存条件
Upon receipt store at 4°C.

よくあるご質問(FAQ)

Are Pierce High Capacity Endotoxin Removal Spin Columns, 1 mL (Cat. No. 88276) autoclavable?

We have not tested this, but the resin is autoclavable up to 121 degrees C at 1 bar for 20 min.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.