GeneChip™ HT MG-430 PM Array Plate
Applied Biosystems™

GeneChip™ HT MG-430 PM Array Plate

Proven performance from the industry standard The GeneChip™HT MG-430 PM 96-Array Plate enables high-throughput expression profiling of multiple samples using詳細を見る
製品番号(カタログ番号)数量
9012581 x 96-array plate
製品番号(カタログ番号) 901258
価格(JPY)
3,618,000
Each
数量:
1 x 96-array plate
Proven performance from the industry standard
The GeneChip™HT MG-430 PM 96-Array Plate enables high-throughput expression profiling of multiple samples using the same industry-standard content as the GeneChip Mouse Genome 430 2.0 Array.*

The HT MG-430 PM Array Plate enables you to:
• Measure gene expression of more than 39,000 transcripts on a single array
• Get accurate and reproducible data by using multiple independent measurements for each transcript

Key Benefits
• Enables increased productivity and efficiency through parallel processing
   - Process 16, 24, or 96 samples on a single array plate
• Same industry-leading performance and content as the Mouse Genome 430 2.0 Array in cartridge format
   - Strong signal and fold change correlation to previous designs
• Multiple independent measurements per transcript for increased confidence in your results
   - Interrogates more sequence than a single probe measurement
• Conveniently packaged
   - Individual 16-, 24-, and 96-array plates available
   - All processing trays included

Content Profile
Sequences used in the design of the array were selected from GenBank™ dbEST and RefSeq. The sequence clusters were created from the UniGene database (Build 107, June 2002) and refined by analysis and comparison with the publicly available draft assembly of the mouse genome from the Whitehead Institute Center for Genome Research (MGSC, April 2002).

*The HT MG-430 PM Array Plate only retains perfect match (PM) probes from the cartridge design. Mismatch (MM) probes were removed.

研究用途にのみご使用ください。診断目的には使用できません。
仕様
製品ラインGeneChip
数量1 x 96-array plate
タイプHT MG-430 PM Array Plate
アレイTranscriptome Profiling
フォーマット96-array Plate
アレイの数96 arrays
Mouse
Unit SizeEach

よくあるご質問(FAQ)

Is the hybridization mix for cartridges the same as the hybridization mix for PEG arrays (array plates)?

The hybridization mix for PEG arrays is different from the hybridization mix for cartridges. The concentrations of the hybridization mix are different and in addition, DMSO is not added into the hybridization mix for PEG arrays because it can affect the glue that holds the PEG to the plate.