The Thermo Scientific™ Nicolet™ Summit™ FTIR Spectrometers can help you reach new heights in productivity, so you can accomplish more in less time. The Summit is ideal for both single-user labs and multi-user labs. Simple yet high-functionality software allows new and experienced users to use the instrument with ease.
製品番号(カタログ番号)内容
912A0972Summit PRO FTIR Spectrometer
912A1139Summit X FTIR Spectrometer
912A1060Summit LITE FTIR Spectrometer
製品番号(カタログ番号) 912A0972
価格(JPY)
-
見積もりを依頼する
内容:
Summit PRO FTIR Spectrometer

Confidently identify sample components and rapidly verify materials with less effort so you can make critical decisions fast. Use the compact Thermo Scientific™ Nicolet™ Summit™ FTIR Spectrometer to quickly see pass/fail QC results on the multi-colored LED LightBar located on the front of the instrument. Reduce the number of steps to take measurements, automate workflows and generate reports with the Thermo Scientific™ OMNIC™ Paradigm Software, run on a built-in Windows™ computer. Send and share data in the Cloud with Wi-Fi connectivity. This spectrometer is ideal for busy QA/QC and teaching labs.

Nicolet Summit FTIR Spectrometer overview
The Nicolet Summit FTIR Spectrometer is available in three different models to help you reach new heights in productivity, so you can accomplish more in less time.

  • Thermo Scientific™ Nicolet™ Summit™ LITE Spectrometer
  • Thermo Scientific™ Nicolet™ Summit™ X Spectrometer
  • Thermo Scientific™ Nicolet™ Summit™ PRO Spectrometer

These are ideal for both single-user labs and multi-user labs. Simple yet high-functionality software allows new and experienced users to use the instrument with ease.

Nicolet Summit FTIR Spectrometer optics
For the ultimate in reliability and accuracy, the Nicolet Summit FTIR Spectrometer is designed with our unique LightDrive Optical Engine.

  • Improved data reproducibility: A state-of-the-art infrared source eliminates hot spot migration, resulting in more consistent spectral data, especially through an attenuated total reflectance (ATR) accessory.
  • Low-cost of ownership: Maintenance is minimized thanks to a 10-year warranty (X and PRO models) and 5-year warranty (LITE model) on IR source, interferometer and laser. Service support contracts and training are also available from Unity™ Lab Services or from our worldwide network of qualified dealers.
  • LITE, X and PRO models: With factory-verified specifications (not just typical or achievable results) you can choose the performance that fits your sample needs while still staying within budget. With the PRO model you can achieve a spectral resolution of 0.45 cm-1. With the Summit X and LITE models you can achieve a spectral resolution of 0.6 cm-1.

Nicolet Summit FTIR Spectrometer materials analysis software
The user-friendly interface of the OMNIC Paradigm Software makes life in the lab less complicated with programmed applications that streamline data acquisition, processing and interpretation.

  • Reduced workflow set-up time: An intuitive, visual workflow creator with a drag-and-drop functionality guides you through the workflow creation and streamlines routine processes.
  • Audit-ready cGxP compliance: Achieve a high level of data integrity with our database infrastructure, data security software, and audit manager applications that keep you compliant with Pharmacopeia (Ph. Eur., USP, JP, and CP) instrument qualification. 21 CFR Part 11 compliance and data security packages are available.
  • Data analysis anytime, anywhere: With full Wi-Fi connectivity you can send data to your Thermo Fisher Connect account in the Cloud and analyze data away from the lab. Or share data and collaborate with colleagues anywhere in the world to accelerate your research. Keep students engaged with data they can access in your teaching lab or in their dorm room.
  • OMNIC Paradigm Desktop Software: Find what you need quickly from the Dashboard screen, create libraries, or perform multi-component searching.
  • Touchscreen or desktop options available for the PRO model: Touchscreen workflows are executed as you run your analysis on a standalone spectrometer that saves space.

Nicolet Summit FTIR Spectrometer uses
Field of use: QA/QC, Forensics, Polymers, Pharma, Environment, Academia/teaching, and many more.

Type of Samples: Analyze solids, liquids and gases.

Type of analysis: Chemical identification, changes in chemical bonds, purity, mixture analysis, contaminant analysis, quantitation.

仕様
光線スプリッターKBr/Ge 中赤外
コンポーネントLightDrive オプティカル エンジンの構成パーツ:光源、レーザー、干渉計、検出器
検出器タイプ電子冷却(TEC)DTGS 検出器、最良のレスポンス・プロファイルを実現   
寸法(奥行き☓幅☓高さ)Spectrometer: 32 x 34 x 24 cm (12.7 x 13.3 x 9.6 in.)
Spectrometer with touchscreen: 32 x 53 x 43 cm (12. x 20.8 x 17.0 in.)
電気的要件100-240 VAC、47-63 Hz、110 W
使用対象(アプリケーション)ポリマーやプラスチック;品質管理QA/QC;製薬;教育;法科学;地質学 - 宝石の分析;自動車;環境
使用対象 (装置)Everest ダイヤモンド ATR;iD アクセサリ(例:iD7 ATR)、サードパーティ製アクセサリ
内容Summit PRO FTIR Spectrometer
光源タイプ標準 – シングルポイント光源、ホットスポットの転移がなく、高い再現性(10 年保証);オプション – 中近赤外測定用のタングステン/ハロゲン光源
スペクトル領域8,000 ~ 350 cm-1 最適化された中赤外 KBr ビームスプリッターによる
スペクトル分解能≦ 0.45 cm-1
重量 (ヤードポンド法)装置重量:24 lbs
タッチスクリーンを装着した状態の装置重量:29 lbs
重量(メートル法)装置重量:10.9 kg
タッチスクリーンを装着した状態の装置重量:12.6 kg
幅(ヤードポンド法)Spectrometer: 13.3 in
Spectrometer with touchscreen: 20.8 in.
幅(メートル法)Spectrometer: 34 cm
Spectrometer with touchscreen: 53 cm
電圧100/240 V
Unit SizeEach

よくあるご質問(FAQ)

What is Raman spectroscopy?

In Raman spectroscopy, an unknown sample of material is illuminated with monochromatic (single wavelength or single frequency) laser light, which can be absorbed, transmitted, reflected, or scattered by the sample. Light scattered from the sample is due to either elastic collisions of the light with the sample's molecules (Rayleigh scatter) or inelastic collisions (Raman scatter). Whereas Rayleigh scattered light has the same frequency (wavelength) of the incident laser light, Raman scattered light returns from the sample at different frequencies corresponding to the vibrational frequencies of the bonds of the molecules in the sample.

If you wish to learn more about Raman spectroscopy, visit our online Raman Spectroscopy Academy (https://www.thermofisher.com/us/en/home/industrial/spectroscopy-elemental-isotope-analysis/spectroscopy-elemental-isotope-analysis-learning-center/molecular-spectroscopy-information/raman-technology.html), where you will find basic Raman tutorials, advanced Raman webinars on sample applications, and a helpful instrument guide.

Using the Beer-Lambert law in FTIR ATR for quantitative analysis of a time-sensitive, migrating substance (e.g., erucamide) in a polymer is difficult. How can this be overcome?

The Beer-Lambert law is based on stable samples and reproducible conditions. In ATR, you have two concerns. First, the sample must make contact with the crystal in a consistent manner. If the material is rough or crystalline, you must ensure reproducibility. Grinding the material to a fine powder may be necessary. Second, ATR is a surface technique, examining the sample to a depth of around 1-4 microns. If the additive or target molecule is migrating further away, you will lose the signal. In this case, transmission, which illuminates the entire sample and entire thickness, may be a viable option (depending upon thickness). In some cases, the application of pressure can change the signal due to changes in the crystallinity or orientation of polymer strands in the sample. Any deeper insights would require an understanding of the specific sample involved.

What types of sampling cells and detectors are used for protein analysis using Fourier Transform Infrared Spectroscopy (FTIR)?

One key experimental step in protein analysis is the removal of the water bands (most proteins are in buffers). This requires highly controlled path-length transmission cells or ATR. Most historical work was done in 6-10 micron path length transmission cells using BaF2 or similar windows. The analytical region is roughly between 1400 and 1750cm-1 where these windows are transmissive. Recently, ATR devices using silicon, germanium, or diamond windows have become more prevalent. Reactions or binding of proteins to the crystal can occur with ZnSe devices (due to surface charges); sometimes this is desired but often it is not. Most of the literature is based on transmission cells. Protein analysis requires skill and consistency, so training is essential for most laboratories.

What is the advantage of DRIFTS compared to ATR technique in Fourier Transform Infrared Spectroscopy (FTIR)? What is the difference?

DRIFTS is used in both mid-IR and near-IR. In the mid-IR, DRIFTS requires the sample be blended with diluents like KBr, with 3-10% sample. This is typically undesirable as the sample is now mixed. However, DRIFTS is heavily used in catalysis research where powdered material is exposed to high temperature, elevated pressures, and mixtures of reactant gases. Several accessory suppliers make devices specific for this. In the near-IR, DRIFTS is used without dilution through direct measurement - many hand-held probes exist allowing analysis through a container wall (like plastic bags) meaning the sample can be analyzed without touching or contaminating it.

ATR involves making contact with the sample by forcing it into contact with a crystal. ATR generally does not require dilution and works well with solids like credit cards or car bumpers which would be tough in DRIFTS. ATR has, for the most part, displaced DRIFTS in the mid-IR except in special cases, while DRIFTS remains a method of choice in the near-IR world.

What are some subtleties and scenarios in inorganic applications for Fourier Transform Infrared Spectroscopy (FTIR)?

Fourier Transform Infrared Spectroscopy (FTIR) responds to a change in dipole moment, regardless of whether it is organic or inorganic. Metal oxides, carbonates, and carbonyls are good examples. The basic equation states that the wavenumber is proportional to the square root of the spring constant (bond strength) and one over the square root of the reduced mass. Simply put, as mass of the atoms involved in the bond goes up, the wavenumber goes down. Many inorganics have peaks below 400cm-1, such as ferrocene, acetylferrocene and cadmium oxide. This necessitates the use of “far-IR” optics. Many forensics users have found far-IR useful in identifying paint chips, due to their inorganic content. There are several ATR accessories that now permit far-IR ATR (mostly monolithic diamond devices). The Thermo Scientific Nicolet iS50 FTIR Spectrometer was designed to make far-IR performance trivial with a built-in ATR as well. Ultimately, if you have further interest in this area, you need to speak with an FTIR sales person to understand the capabilities and limitations.