High Select™ Depletion Spin Columns
High Select™ Depletion Spin Columns
High Select™ Depletion Spin Columns
High Select™ Depletion Spin Columns
Thermo Scientific™

High Select™ Depletion Spin Columns

Thermo Scientific High Select HSA/Immunoglobulin Depletion Resinは、ヒト血漿サンプル中に高量に存在するアルブミンおよび抗体成分を低減し、これらのサンプルを質量分析または1D/2D電気泳動用に調製するのに役立ちます。このレジンは詳細を見る
製品番号(カタログ番号)数量製品タイプ精製標的
A3637250 mL樹脂Top14 Abundant Protein
A363656カラムスピンカラムHSA/Immunoglobulin
A3636624カラムスピンカラムHSA/Immunoglobulin
A3636710 ColumnsスピンカラムHSA/Immunoglobulin
A3636850 mL樹脂HSA/Immunoglobulin
A3637110 ColumnsスピンカラムTop14 Abundant Protein
A363696カラムスピンカラムTop14 Abundant Protein
A3637024カラムスピンカラムTop14 Abundant Protein
製品番号(カタログ番号) A36372
価格(JPY)
569,300
Each
お問い合わせください ›
数量:
50 mL
製品タイプ:
樹脂
精製標的:
Top14 Abundant Protein
Thermo Scientific High Select HSA/Immunoglobulin Depletion Resinは、ヒト血漿サンプル中に高量に存在するアルブミンおよび抗体成分を低減し、これらのサンプルを質量分析または1D/2D電気泳動用に調製するのに役立ちます。このレジンは、10 µLのサンプルの処理に便利なシングルユースミニスピンカラムフォーマットで提供されます。

HSA/IgG除去レジンの特長:
•柔軟—ミニカラムフォーマットは、10 µLのヒト血漿サンプルを処理するようにサイズ調整および最適化済み
• 最適化済み—95%超のIgGと、95%超のアルブミンを除去
• 高速 —サンプルを約10分で処理
• 経済的—シングルユース向けに価格設定されたコスト効率の高いスピンカラム
• ばらつきの低減—1回限りの使用であるため、タンパク質のキャリーオーバーや実験間のばらつきを防止

High Select HSA/Immunoglobulin Depletion Resinは、特異性の高い固定化抗HSAおよび抗イムノグロブリン抗体(IgG、IgA、IgM、IgD、およびIgE)を使用しており、血清および血漿からヒト血清アルブミン(HSA)やイムノグロブリンのすべての主要サブクラスを除去します。この樹脂は、ワンステップ処理とシングルユース用に特別に設計された経済的で便利なスピンカラムフォーマットで提供されています。

ヒトの体液の分析は、総血清タンパク質の70%強を占める高濃度のアルブミンおよびIgGの存在により複雑になることがよくあります。少量タンパク質の研究では多くの場合、このようなタンパク質の除去が不可欠です。High Select HSA/Immunoglobulin Depletion Resinは、HSAを95%超、IgGを95%超除去できます。サンプルを充填済みのディスポーザブルスピンカラムにロードすると、約10分で処理されます。多量のタンパク質を除去することで、サンプル中の微量タンパク質の検出や、質量分析または1D/2Dゲル電気泳動による同定が可能になります。

推奨製品
High Select Top14 Abundant Protein Depletion Mini Spin Columns
High Select Top14 Abundant Protein Depletion Resin
TMT10plex Isobaric Label Reagent Set, 3 x 0.8 mg
For Research Use Only. Not for use in diagnostic procedures.
仕様
最終産物タイプタンパク質
使用対象 (装置)Mass Spectormeter
標識または色素非標識
精製標的Top14 Abundant Protein
数量50 mL
出荷条件湿氷
ワークフローステップProtein Depletion
形状Liquid
製品ラインHigh Select
製品タイプ樹脂
原料Plasma, Serum
Unit SizeEach
組成および保存条件
2~8℃で保存してください。

よくあるご質問(FAQ)

Is there a 96-well format available for the Top14 Abundant Protein Depletion Mini Spin Columns (Cat. No. A36369)?

No. The Top14 Abundant Protein Depletion Mini Spin Columns (Cat. No. A36369) do not come in a 96-well format. However, we do have a Top14 Abundant Protein Depletion Resin (Cat. No. A36372) that can be purchased as a stand-alone product.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

After depletion of abundant proteins from my sample, I still see albumin and other abundant proteins after LC-MS analysis. Did the depletion work?

Depletion does not remove all abundant proteins from the sample. Even with 99% depletion of a specific plasma protein, highly abundant proteins will still be the most abundant proteins in the sample detected by MS analysis. However, depletion significantly decreases the most abundant plasma proteins enabling identification of lower abundant proteins.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

How do I proceed to downstream mass spec sample preparation after abundant plasma protein depletion?

After the depletion, samples are significantly diluted in buffer. Depleted samples should be concentrated by speed vac drying, solvent precipitation, or diafiltration. Samples dried using a speedvac are directly compatible with the EasyPep kit chemistry after resuspension using the Lysis Solution.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

What is the maximum loading capacity for the High Select Depletion columns?

Mini columns can deplete up to 10 µL (600 µg) of plasma or serum; midi columns can deplete up to 100 µL (6000 µg) of plasma or serum.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

What is the percentage of albumin that is removed using abundant protein depletion columns?

More than 99% of albumin can be depleted when columns use the recommended sample to resin ratio.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.