SureQuant™ IP-MS Sample Preparation Kits
SureQuant™ IP-MS Sample Preparation Kits
Thermo Scientific™

SureQuant™ IP-MS Sample Preparation Kits

Thermo Scientific SureQuant IP-MS Sample Preparation Kits provide an optimized solution for the immunoprecipitation and MS peptide preparation of samples upstream of LC-MS/MS analysis.
製品番号(カタログ番号)概要
A51743Protein A/G Magnetic Beads
A51744Streptavidin Magnetic Beads
製品番号(カタログ番号) A51743
価格(JPY)
66,200
キャンペーン価格
Ends: 27-Mar-2026
110,400
割引額 44,200 (40%)
Each
お問い合わせください ›
概要:
Protein A/G Magnetic Beads
Thermo Scientific SureQuant IP-MS Sample Preparation kits (Protein A/G or streptavidin) provide an optimized solution for the immunoprecipitation and MS peptide preparation of samples upstream of LC-MS/MS analysis. These kits have been rigorously verified using numerous multiplexed target antigens with varying expression levels. The SureQuant product family enables the use of the immunoprecipitation (IP) sample prep kits and peptide quantitation modules together or independently for SRM/PRM analysis.
Complete—kits include reagents for successful immunoprecipitation and MS peptide preparation for target proteins for SRM/PRM analysis
Multiplex—IP-MS kits have been designed for multiplex IP using both Protein A/G and Streptavidin magnetic beads
Flexible—universal reagents enable individualized selection of targets for IP to be used alone or combined with SureQuant peptide quantitation panels
Optimized—simplified and condensed procedure to prepare samples for LC-MS analysis
Low background—binding, wash, and elution buffers optimized to remove contaminants and minimize enrichment of background proteins

The SureQuant Protein A/G and Streptavidin IP-MS Sample Preparation kits have been designed to support targeted quantitation using SureQuant or SRM/PRM analysis. The kits contain high-quality Pierce Protein A/G or Streptavidin magnetic beads together with reagents that have been optimized for MS compatibility. The streamlined procedure enables digestion immediately after the immunoprecipitation elution step, facilitating MS sample preparation in ∼4 hours for same-day LC-MS/MS analysis.

Applications:
• Enrichment of low abundance targets to improve MS sensitivity
• Identification of target proteins that are not detectable by western blotting
• Quantitation of target proteins by LC-MS analysis
• Screening of antibodies for IP-MS
• Enrichment of target proteins upstream of targeted analysis (SRM)

仕様
概要Protein A/G Magnetic Beads
使用対象(アプリケーション)MS-compatible immunoprecipitation
使用対象 (装置)Mass spectrometer
キット内容Trypsin Protease, 2 x 20 μg
Trypsin Storage Solution, 250 μL
Protein A/G Magnetic Beads, 1 mL
IP-MS Cell Lysis Buffer, 100 mL
IP-MS Wash Buffer A, 75 mL
IP-MS Wash Buffer B, 40 mL
IP Elution and MS Sample Prep Buffer, 10 mL
Alkylation Solution, 1 mL/vial
Low Protein-Binding Collection Tubes, 50 x 1.5 mL
Bond-Breaker™ TCEP Solution, Neutral pH, 0.5 mL
10% Pierce™ Trifluoroacetic Acid (TFA), Sequencing Grade, 0.5 mL
1M MgCl2, 0.75 mL
数量20 Reactions
ワークフローステップSample prep enrichment
検出法Mass Spectrometry
製品ラインSureQuant
原料Cells, Tissue
Unit SizeEach
組成および保存条件
Store trypsin at 4°C.
Store trypsin storage solution at -20°C.

よくあるご質問(FAQ)

Why is the processing time for MS analysis less with SureQuant IP-MS Sample Preparation kits compared to traditional IP methods?

SureQuant Protein IP-MS Sample Preparation kits use a trypsin enzyme elution method to dissociate the bound immune complexes from the magnetic beads, which can then be digested directly in-solution and followed up by MS analysis on the same day; no SDS-PAGE purification is required. The entire process take 4 hours compared to traditional IP methods that usually take around 21 hrs.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

What is the difference between SureQuant IP-MS Sample Preparation kits and Pierce MS-Compatible Magnetic IP kits?

SureQuant IP-MS Sample Preparation kits include all reagents necessary for sample lysis, immunoenrichment, elution, digestion, and MS analysis. The entire process is completed in 4 hr for same-day LC-MS/MS analysis as compared to traditional IP methods that usually take around 21 hr. Pierce MS-Compatible Magnetic IP kits provide reagents necessary for the lysis step and the elution step, but not for the digestion step prior to MS analysis.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

Can I use SureQuant Protein A/G and SureQuant Streptavidin IP-MS Sample Preparation kits with any sample?

SureQuant IP-MS sample preparation kits have been designed for use with SureQuant quantitation modules for upstream sample preparation for SRM/PRM analysis, but they can be used with any samples where the target protein needs to be enriched by IP or IP-CoIP, prior to MS analysis.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.