このアミン反応性色素6-JOE、SEの単一異性体調製は、蛍光特性があり、蛍光色素と比較して赤色にシフトします(励起/発光は522/550 nm)。自動DNAシーケンシングに使用される従来の蛍光色素の一つです詳細を見る
製品番号(カタログ番号)数量
C6171MP5 mg
製品番号(カタログ番号) C6171MP
価格(JPY)
48,400
온라인 행사
Ends: 27-Mar-2026
80,800
割引額 32,400 (40%)
Each
数量:
5 mg
このアミン反応性色素6-JOE、SEの単一異性体調製は、蛍光特性があり、蛍光色素と比較して赤色にシフトします(励起/発光は522/550 nm)。自動DNAシーケンシングに使用される従来の蛍光色素の一つです。
研究用にのみ使用できます。診断用には使用いただけません。
仕様
化学反応性アミン
発光550
励起522
標識または色素JOE
製品タイプ6-JOE SE
数量5 mg
反応性部分活性エステル、スクシンイミジルエステル
出荷条件室温
標識タイプ従来の色素
Unit SizeEach
組成および保存条件
フリーザー(-5~-30度)に保存し、遮光してください。

引用および参考文献 (15)

引用および参考文献
Abstract
Ultra-high-speed DNA sequencing using capillary electrophoresis chips.
Authors:Woolley AT, Mathies RA
Journal:Anal Chem
PubMed ID:8644919
'DNA sequencing has been performed on microfabricated capillary electrophoresis chips. DNA separations were achieved in 50 x 8 microns cross-section channels microfabricated in a 2 in. x 3 in. glass sandwich structure using a denaturing 9% T, 0% C polyacrylamide sieving medium. DNA sequencing fragment ladders were produced and fluorescently ... More
Real-time PCR in the microbiology laboratory.
Authors:Mackay IM
Journal:Clin Microbiol Infect
PubMed ID:15008940
'Use of PCR in the field of molecular diagnostics has increased to the point where it is now accepted as the standard method for detecting nucleic acids from a number of sample and microbial types. However, conventional PCR was already an essential tool in the research laboratory. Real-time PCR has ... More
Energy-transfer fluorescent reagents for DNA analyses.
Authors:Glazer AN, Mathies RA
Journal:Curr Opin Biotechnol
PubMed ID:9013654
'Fluorescence resonance energy transfer has facilitated the development of a new class of high-performance fluorescent labeling reagents for multiplex analyses of nucleic acids. The enhanced emission of energy transfer (ET) primers has provided a decadic improvement in the performance of automated DNA sequencers. The emission spectral purity of ET primers ... More
Energy transfer primers with 5- or 6-carboxyrhodamine-6G as acceptor chromophores.
Authors:Hung SC, Ju J, Mathies RA, Glazer AN
Journal:Anal Biochem
PubMed ID:8660606
'Energy-transfer (ET) fluorescent primers for DNA sequencing and multiplex genetic analysis (Ju, J., Ruan, C., Fuller, C. W., Glazer, A. N., and Mathies, R. A. (1995) Proc. Natl. Acad. Sci. USA 92, 4347-4351) are named according to the convention D-N-A, where D is the donor, N is the number of ... More
Fluorescence excitation transfer immunoassay (FETI).
Authors:Ullman EF, Khanna PL
Journal:Methods Enzymol
PubMed ID:7033726