Flow Cytometer Calibration and Size Reference Beads
- Confidence—ensure the reliability of optimal daily instrument performance
- Reliability—minimal variation for consistent data acquisition
- Compatibility—full range of tools for any instrument
Instrument calibration is critical to collecting and analyzing accurate experimental data. Our flow cytometer alignment and cell sorting beads are designed to help ensure your flow cytometer is performing at its peak, your experimental design is robust, and the data you collect and analyze are accurate. In addition, our size calibration and size reference kits serve as reliable size references for flow cytometer users.
On this page:
- Instrument calibration
- Size calibration
- Sub-micron particle size reference
- Cell sorter calibration
Flow cytometer calibration beads selection guide
Rainbow Calibration Particles | AlignFlow Flow Cytometry Alignment Beads | ||||||
---|---|---|---|---|---|---|---|
Use | Routine calibration of flow cytometers | ||||||
Contents | Single mixture of particles featuring 8 different fluorescent intensities. | Single fluorescence, laser-specific particles available in three versions (per laser excitation). | |||||
Laser type | UV to red laser | UV laser | Blue laser | Red laser | |||
Excitation | 365–650 nm | 350–370 nm | 488 nm | 633 nm | |||
Emission | 400–680 nm | 400–470 nm | 515–660 nm | 645–680 nm | |||
Bead diameter | 3.0–3.4 micron | 2.5 micron | 6.0 micron | 2.5 micron | 6.0 micron | 2.5 micron | 6.0 micron |
Cat. No. | A34305 | A16502 | A16505 | A16500 | A16503 | A16501 | A16504 |
Flow Cytometry Size Calibration Kit | |
---|---|
Use | Estimate the size of cells in an experimental sample by comparing the FSC signals with those of the reference microspheres. |
Contents | Contains six suspensions of unstained polystyrene microspheres (1.0 micron to 15 micron diameter). |
Laser type | Any |
Cat. No. | F13838 |
Flow Cytometry Sub-micron Particle Size Reference Kit | |
---|---|
Use | Check any of the following:
|
Contents | Set of 6 green-fluorescent microsphere suspensions (0.02 micron to 2.0 micron diameter). |
Laser type | Blue laser |
Laser | 488 nm |
Emission | 515 nm |
Cat. No. | F13839 |
Cell sorting set up beads | ||||
---|---|---|---|---|
Use | Routine calibration of flow cytometry sorters. Beads can be used to check cell sorter settings such as drop delay and efficiency (cell loss during sorting). | |||
Contents | Fluorescent-dye infused 6 micron (+/– 10%) microspheres that have been optimized for use with either UV, blue, green/yellow and red lasers. | |||
Laser type | UV | Blue laser | Green/yellow laser | Red laser |
Laser | UV 405 nm | 488 nm | 532/561 nm | 633 nm |
Emission | 460 nm | 515 nm | 575 nm | 680 nm |
Fluorophore matches | DAPI, Hoechst dyes | FITC, Alexa Fluor 488 | R-PE, tetramethylrhodamine | Cy 5 |
Cat. No. | C16505 | C16508 | C16509 | C16507 |
Rainbow Calibration Particles | AlignFlow Flow Cytometry Alignment Beads | ||||||
---|---|---|---|---|---|---|---|
Use | Routine calibration of flow cytometers | ||||||
Contents | Single mixture of particles featuring 8 different fluorescent intensities. | Single fluorescence, laser-specific particles available in three versions (per laser excitation). | |||||
Laser type | UV to red laser | UV laser | Blue laser | Red laser | |||
Excitation | 365–650 nm | 350–370 nm | 488 nm | 633 nm | |||
Emission | 400–680 nm | 400–470 nm | 515–660 nm | 645–680 nm | |||
Bead diameter | 3.0–3.4 micron | 2.5 micron | 6.0 micron | 2.5 micron | 6.0 micron | 2.5 micron | 6.0 micron |
Cat. No. | A34305 | A16502 | A16505 | A16500 | A16503 | A16501 | A16504 |
Flow Cytometry Size Calibration Kit | |
---|---|
Use | Estimate the size of cells in an experimental sample by comparing the FSC signals with those of the reference microspheres. |
Contents | Contains six suspensions of unstained polystyrene microspheres (1.0 micron to 15 micron diameter). |
Laser type | Any |
Cat. No. | F13838 |
Flow Cytometry Sub-micron Particle Size Reference Kit | |
---|---|
Use | Check any of the following:
|
Contents | Set of 6 green-fluorescent microsphere suspensions (0.02 micron to 2.0 micron diameter). |
Laser type | Blue laser |
Laser | 488 nm |
Emission | 515 nm |
Cat. No. | F13839 |
Cell sorting set up beads | ||||
---|---|---|---|---|
Use | Routine calibration of flow cytometry sorters. Beads can be used to check cell sorter settings such as drop delay and efficiency (cell loss during sorting). | |||
Contents | Fluorescent-dye infused 6 micron (+/– 10%) microspheres that have been optimized for use with either UV, blue, green/yellow and red lasers. | |||
Laser type | UV | Blue laser | Green/yellow laser | Red laser |
Laser | UV 405 nm | 488 nm | 532/561 nm | 633 nm |
Emission | 460 nm | 515 nm | 575 nm | 680 nm |
Fluorophore matches | DAPI, Hoechst dyes | FITC, Alexa Fluor 488 | R-PE, tetramethylrhodamine | Cy 5 |
Cat. No. | C16505 | C16508 | C16509 | C16507 |
Rainbow Calibration Particles
Rainbow Calibration Particles contain a mixture of 3.0 micron particles in different fluorescent intensities. The calibration particles can be used for routine calibration of flow cytometers using wavelengths ranging from 365 nm to 650 nm.
- Read the Rainbow Calibration Particles manual
AlignFlow Flow Cytometry Alignment Beads
Invitrogen AlignFlow Flow Cytometry Alignment Beads are reliable references for aligning, focusing, and calibrating flow cytometers. These fluorescently stained polystyrene microspheres are highly uniform with respect to size and fluorescence intensity (Figure 3), and are designed to approximately replicate the size, emission wavelength, and intensity of biological samples. Because the dyes are contained inside the microsphere’s matrix, instead of on the bead’s surface, AlignFlow beads have excellent photochemical and physical stability, providing reliable reference signals for instrument set-up. The fluorescent dyes have been carefully selected for optimal excitation by laser sources commonly used in flow cytometry.
The AlignFlow beads are available in three versions: for 350–370 nm excitation with UV lasers, for 488 nm excitation with blue lasers, and for 633 nm excitation with red lasers. Each version is available in two bead sizes: 2.5 μm diameter and 6.0 μm diameter. See table below for product selection.
- Read the AlignFlow product manual
Figure 3. Invitrogen AlignFlow flow cytometry alignment beads excited at 488 nm by an argon-ion laser and monitored in three emission channels. The broad fluorescence emission is detected in all three channels. Note the exceptionally small variation of fluorescence intensity of the beads. Contributed by Carleton Stewart, Roswell Park Cancer Institute.
Size calibration
The Invitrogen Flow Cytometry Size Calibration Kit provides a set of nonfluorescent microsphere suspensions to serve as reliable size references for cytometry users. The kit contains six suspensions of unstained polystyrene microspheres, each with a known diameter, determined by transmission electron microscopy. The size of cells in an experimental sample can be estimated by comparing the forward scatter (FSC) signals with those of the reference microspheres. The microspheres function as reproducible size markers (Figure 4) and can be intermixed with the experimental sample or used in parallel runs.
Figure 4. Invitrogen Flow Cytometry Size Calibration Kit. Histogram analysis of the forward scatter intensity (FSC) log channel values of the six polystyrene microsphere samples supplied in the Flow Cytometry Size Calibration Kit is shown. FSC measurements were performed on a Becton Dickinson FACScan™ flow cytometer using excitation at 488 nm.
Sub-micron particle size reference
The Invitrogen Flow Cytometry Sub-micron Particle Size Reference Kit provides a set of green-fluorescent microsphere suspensions to serve as reliable size references for flow cytometry users. The kit contains six suspensions of polystyrene microspheres, each with a known diameter as determined by transmission electron microscopy. The excitation and emission profile of all the beads is similar to Invitrogen Alexa Fluor 488 dye– or FITC-stained cells (excitation and emission maxima are 505 nm and 515 nm, respectively).
The size (or size range) of bioparticles in an experimental sample can be estimated by comparing their FSC with those of the reference microspheres (Figure 5). The microspheres in each component function as reproducible size markers and can be used individually (one size), premixed (two to six sizes), intermixed with the experimental sample, or in parallel runs. This kit can be used to verify instrument performance and to establish parameters that are suitable for analyzing sub-micron particles. For example, the kit can be used to check:
- Resolution limit and dynamic range of particle size measurement
- Sensitivity of forward and side scatter photomultiplier tubes
- Level of instrument baseline noise
- Laser and optical alignment and stability
- Stability of the fluidics system
Figure 5. Invitrogen Flow Cytometry Sub-micron Particle Size Reference Kit. Signals from (the kit has six particle sizes; only five were used here) five different-sized particles of the Flow Cytometry Sub-micron Particle Size Reference Kit were acquired using 488 nm excitation and a 530/30 nm band pass (BP) emission filter on the Attune Acoustic Focusing Cytometer. The diameters of the five different green-fluorescent microspheres are identified on a plot of particle fluorescence versus side scatter.
Cell sorting set up beads
Invitrogen Cell Sorting Set-Up Beads are reliable standards for the set-up and calibration of flow cytometry sorter instruments. The beads have a diameter of 6 μm (±10%), and thus approximate the size, emission wavelength, and intensity of many biological samples. Consequently, the beads can be used to check cell sorter settings such as drop delay and efficiency (cell loss during sorting). The beads can also be used to calibrate a flow cytometer’s laser source, optics, and stream flow without wasting valuable and sensitive experimental material.
Figure 6. Normalized emission spectra of Invitrogen Cell Sorting Set-up Beads for Blue Lasers solid line) and fluorescein-labeled cells (dashed line). The narrow emission spectrum of Cell Sorting Set-up Beads for Blue Lasers is approximately centered on the broader emission spectrum of fluorescein.
Resources
Flow Cytometry Learning Center—Access flow cytometry educational resources for better experiment planning and execution.
Flow Cytometry Panel Builderbeta—Design your flow cytometry panel with this online tool for a simplified, customizable experience to fit your needs.
Support
Flow Cytometry Support Center—Find technical support recommendations for your flow cytometry workflows, including tips for experimental setup and in-depth troubleshooting help.
For Research Use Only. Not for use in diagnostic procedures.