Genexus™ GX5™ Starter Pack-HD
Ion Torrent™

Genexus™ GX5™ Starter Pack-HD

The Ion Torrent Genexus GX5 Starter Pack for Ion AmpliSeq HD panels provides one set of all core consumables required詳細を見る
製品番号(カタログ番号)数量
A4028032 Reactions
製品番号(カタログ番号) A40280
価格(JPY)
1,620,000
Each
数量:
32 Reactions
The Ion Torrent Genexus GX5 Starter Pack for Ion AmpliSeq HD panels provides one set of all core consumables required to run the Ion Torrent Genexus Integrated Sequencer. This starter pack supports flexible, fully automated preparation and normalization of up to 32 Ion AmpliSeq HD libraries, as well as sequencing for up to eight chip lanes (two full chips). The Ion Torrent GX5 Chip is used in conjunction with this starter pack and must be ordered separately.

As part of the Genexus Integrated Sequencer GX5 workflow, the Genexus GX5 Starter Pack-HD:
• Automates library preparation, templating, and sequencing for 200–400 base-read Ion AmpliSeq HD libraries
• Supports intake variability of clinical research samples in a cost-effective manner
• Maximizes flexibility with the ability to sequence one to four chip lanes per run
• Enables parallel processing of up to four compatible assays in a single run
• Delivers fast and simple instrument set-up, with less than five minutes of hands-on time

The Ion Torrent Genexus Integrated Sequencer automates library preparation, sequencing, analysis, and reporting in a hands-off, walkaway workflow to deliver results in a single day. The innovative, multilane sequencing chip is designed to enable cost-effective processing of 1 to 32 single pool libraries.

研究用途にのみご使用ください。診断目的には使用できません。
仕様
使用対象(アプリケーション)Comparative Sequencing (Somatic Mutations - 10:50)
使用対象 (装置)Genexus Integrated Sequencer
反応数32
製品ラインGX5, Genexus
製品タイプStarter Pack-AS
数量32 Reactions
出荷条件Approved for shipment at Room Temperature or on Wet or Dry Ice
Unit SizeEach
組成および保存条件
1 each of:
• Genexus Strip 2-HD, store at -10 to -20°C
• Genexus Strip 1, store at 2–8°C
• Genexus Barcodes 1-32 HD, store at room temperature
• Genexus Strip 4, store at -10 to -20°C
• Genexus Strip 3-GX5, store at 2–8°C
• Genexus Pipette Tips, store at room temperature
• Genexus Cartridge, store at -10 to -20°C
• Genexus Bottle 2, store at room temperature
• Genexus Bottles 1 and 3, store at room temperature

よくあるご質問(FAQ)

What are the correct shipping conditions for the Genexus Cartridges that are a part of the Genexus Sequencing Kit (Cat. No. A40271) and Genexus GX5 Starter Packs (Cat. Nos. A40279, A40280)?

The Genexus Cartridge should be shipped on supergels at -15 to -50 degrees C, in a polystyrene box. If the cartridges are shipped with dry ice or arrive thawed, they should not be used, and replacement would need to be issued.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

What are the components of the Genexus GX5 Starter Pack-HD?

Genexus GX5 Starter Pack-HD (Cat. No. A40280) supplies the following components for Ion AmpliSeq HD library preparation and sequencing using a Genexus-ready assay:
- Genexus Strip 1, 8 strips
- Genexus Strip 2‑HD, 8 strips
- Genexus Strip 3‑GX5, 8 strips
- Genexus Strip 4, 8 strips
- Genexus Barcodes 1-32 HD, 1 plate
- Genexus Pipette Tips, 12 racks
- Genexus Cartridge, 2 cartridges
- Genexus Bottle 2, 4 bottles
- Genexus Bottles 1 and 3, 2 bottles each
Note:
- Genexus Barcodes 1-32 HD (Cat. No. A40261) and Genexus Pipette Tips (Cat. No. A40266) are also orderable individually.
- Library and template strips are orderable separately in paired sets as Genexus Library Strips 1 and 2-HD (Cat. No. A40255) and Genexus Templating Strips 3 and 4-GX5 (Cat. No. A40263).
- The Genexus Cartridge, Genexus Bottle 2, and Genexus Bottles 1 and 3 are orderable as a set in the Genexus Sequencing Kit (Cat. No. A40271).
- For custom assays, Genexus Primer Pool Tubes (Cat. No. A40262) must be ordered separately.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.