GX7 Chip and Genexus™ Coupler
GX7 Chip and Genexus™ Coupler
Ion Torrent™

GX7 Chip and Genexus™ Coupler

The Ion Torrent GX7 Chip and Genexus Coupler includes two GX7 chips and two Genexus couplers, sufficient for two initializations詳細を見る
製品番号(カタログ番号)数量
A467312 Runs
製品番号(カタログ番号) A46731
価格(JPY)
288,400
Each
お問い合わせください ›
数量:
2 Runs

The Ion Torrent GX7 Chip and Genexus Coupler includes two GX7 chips and two Genexus couplers, sufficient for two initializations of the Genexus Integrated Sequencer. The GX7 Chip generates 20–25 million sequencing reads per lane, or 80–100 million reads per chip. The four-lane chip design supports maximum flexibility for sample processing, enabling sequencing of one to four lanes per run, with the in-use stability to utilize any remaining lanes within two weeks of the initial run.

As part of the Genexus Integrated Sequencer workflow, the GX7 Chip:
• Achieves 20–25 million reads per lane for 200 base-read libraries
• Maximizes flexibility with the ability to utilize one to four chip lanes per run
• Enables parallel processing of up to four compatible assays in a single run
• Supports intake variability of clinical research samples

The Genexus Integrated Sequencer automates library preparation, sequencing, analysis, and reporting in a hands-off, walkaway workflow to deliver results in a single day. The innovative, multilane sequencing chip is designed to enable cost-effective processing of 1 to 32 single pool libraries.
 

研究用途にのみご使用ください。診断目的には使用できません。
仕様
数量2 Runs
フォーマットKit
Isolation TechnologyBeads
Unit SizeEach

よくあるご質問(FAQ)

Can I use the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) with the GX5 Chip?

No, the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) should be used with the GX7 Chip. Each kit allows for the automated template preparation and chip loading of two GX7 chips using the Genexus Integrated Sequencer.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

What are the storage conditions for the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817)?

The Genexus Strip 3-GX7 should be stored at 2-8 degrees C and Genexus Strip 4 should be stored at -30 to -10 degrees C.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

What does the Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) consist of?

The Genexus Templating Strips 3-GX7 and 4 Kit (Cat. No. A46817) consists of 8 pairs of 3-GX7 and 4 strips, allowing for up to 2 sequencing runs per kit.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

What Genexus Software version is compatible with the GX7 Chip?

The GX7 Chip is compatible with the Genexus Software version 6.8.0 and later.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.

Can the Genexus Coupler be reused?

The Genexus Coupler should not be reused. The chip and coupler should be changed together.

Find additional tips, troubleshooting help, and resources within our Next-Generation Sequencing Support Center.