Thermo Scientific™

CM515 and HME900 Density Converter Electronics

Catalog number: 15472
Thermo Scientific™

CM515 and HME900 Density Converter Electronics

Catalog number: 15472
Achieve optimum data processing with Thermo Scientific™ CM515 and HME900 Density Converter Electronics. Thermo Scientific density meters or specific gravity analyzers are available with either a HART compatible, field-mounted density converter or a control room-based unit. Both instruments provide high-integrity calculations of density and density-related variables to ensure effective custody transfer and process optimization.
 
Catalog Number
15472
Unit Size
Each
Product Type
Density Converter Electronics
Price (USD)
Full specifications
Product TypeDensity Converter Electronics
Environmental RatingIP65 (NEMA 4X)
Ambient HumidityUp to 95% Non-Condensing
Certifications/ComplianceATEX and CSA/US; Compliant with CE Mark, Electromagnetic Compatibility (EN61326:1997), Low Voltage Directive,
CommunicationsUses HART communications protocol; WinHME900 PC configuration program; Handheld communicator (e.g. Emerson 375 Field Communicator)
ConnectionsScrew Terminals Suitable for Wire Sizes to 1.5 sq. mm (0.06 sq. in.)
Data StorageConfigurations, Settings, and Data Retained in e2 Non-Volatile Storage
DescriptionCM515 and HME900 Density Converter Electronics
Display4.5-digit 7.6 mm (0.3 in.) 7 Segment LCD Display
Outputs4 to 20 mA HART: Operating Voltage: 8 to 28 VDC at Terminals; Resolution: 0.015% Span; Accuracy at Reference +20deg;C (+68°deg;F): ±0.1% of Point; Drift -20deg;C to +50deg;C (-4deg;F to +122deg;F): ±0.08% Full Scale Typical; ±0.175% Full Scale Max
Temperature MeasurementTemperature (PT100 RTD): Range: -200°C to +200°C (-328°F to 392°F); Resolution: better than 0.0015%; Accuracy at +20°C (+68°F) reference: ±0.1°C (±0.18°F); -200°C to +200°C (-328°F to +392°F) ±0.05°C (±0.09°F); 0°C to +200°C (+32°F to +392°F); Drift -20°C to +50°C (-4°F to +122°F): ±0.05°C (±0.09°F) typical, ±0.01°C (±0.018°F) max
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeProduct TypePrice (USD)
15472Full specifications
EachDensity Converter ElectronicsRequest A Quote
Product TypeDensity Converter Electronics
Environmental RatingIP65 (NEMA 4X)
Ambient HumidityUp to 95% Non-Condensing
Certifications/ComplianceATEX and CSA/US; Compliant with CE Mark, Electromagnetic Compatibility (EN61326:1997), Low Voltage Directive,
CommunicationsUses HART communications protocol; WinHME900 PC configuration program; Handheld communicator (e.g. Emerson 375 Field Communicator)
ConnectionsScrew Terminals Suitable for Wire Sizes to 1.5 sq. mm (0.06 sq. in.)
Data StorageConfigurations, Settings, and Data Retained in e2 Non-Volatile Storage
DescriptionCM515 and HME900 Density Converter Electronics
Display4.5-digit 7.6 mm (0.3 in.) 7 Segment LCD Display
Outputs4 to 20 mA HART: Operating Voltage: 8 to 28 VDC at Terminals; Resolution: 0.015% Span; Accuracy at Reference +20deg;C (+68°deg;F): ±0.1% of Point; Drift -20deg;C to +50deg;C (-4deg;F to +122deg;F): ±0.08% Full Scale Typical; ±0.175% Full Scale Max
Temperature MeasurementTemperature (PT100 RTD): Range: -200°C to +200°C (-328°F to 392°F); Resolution: better than 0.0015%; Accuracy at +20°C (+68°F) reference: ±0.1°C (±0.18°F); -200°C to +200°C (-328°F to +392°F) ±0.05°C (±0.09°F); 0°C to +200°C (+32°F to +392°F); Drift -20°C to +50°C (-4°F to +122°F): ±0.05°C (±0.09°F) typical, ±0.01°C (±0.018°F) max
Unit SizeEach
Showing 1 of 1
Thermo Scientific HME900:
The durable HME900 head-mounted density converter may be included with any Thermo Scientific liquid or gas density meter or specific gravity analyzer. This unit conditions the output signal to provide a HART compatible 4-20mA signal that can be connected directly to the user's DCS or it can be read digitally. An optional local display enables viewing of the prime variable value either in engineering units alone or with an alternating display of percent of chosen span. The HME900 is ideal for most general density measurement applications and where HART communications are required.
Thermo Scientific CM515 (formerly CM200):
The versatile CM515 density converter accepts inputs from Thermo Scientific density meters. This easy-to-use device derives density at reference conditions, calculates density derived parameters and is compatible with a wide range of density meter pulse outputs. Parameters and calibration data can be monitored using either the RS-232 or RS-485 interface option. The CM515 is best suited to applications that require a greater degree of input/output flexibility than offered by the HME900 or when HART compatibility is not required.
Features:
  • High accuracy calculations
  • Choice of field or control room installation
  • Flexible input into user DCS
  • Extensive range of standard calculations
  • Customer-defined function (CDF) for non-standard calculation
Inputs:
Pressure (4 to 20mA)
  • Resolution: better than 0.01%
  • Accuracy at 20°C (68°F) reference: better than 0.1% point
  • Drift -20°C to +50°C (-4°F to +122°F): ±0.1% typical, ±0.2% max
Period (current pulse 6 to 18mA)
  • Range: 10ms to 250µs (100Hz to 4000Hz)
  • Standard range: 2500µs to 250µs (400Hz to 4000Hz)
  • Resolution: ±2ns
  • Accuracy at reference +20°C (+68°F): as resolution
  • Drift -20°C to +50°C (-4°F to +122°F): ±25 ppm typical; ±50 ppm max
Temperature (PT100 RTD)
  • Range: -200° to +200°C (-328° to 392°F)
  • Resolution: better than 0.0015%
  • Accuracy at +20°C (+68°F) reference: ±0.1°C (±0.18°F); -200° to +200°C (-328° to +392°F) ±0.05°C (±0.09°F); 0° to +200°C (+32° to +392°F)
  • Drift -20° to +50°C (-4° to +122°F): ±0.05°C (±0.09°F) typical, ±0.01°C (±0.018°F) max
Compatible with:
  • Thermo Scientific FD910, FD950 and FD960 Liquid Density Meters
  • Thermo Scientific FD900, ID900 and PD900 Gas Density Meters
  • Thermo Scientific SG901 Specific Gravity Analyzer

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References