Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Detectable Analytes | Methane and Nonmethane Hydrocarbons |
Flow Rate | 0.5 L/min. |
Inputs | 16 Digital Inputs, User Select Programmable, TTL Level, Pulled High |
Linearity | ±2% of span (at concentrations of 10 to 100% of span) |
Response Time | 70 sec. |
Span Drift | <2% span value (without auto calibration) |
Zero Noise | 0.025 ppm RMS |
Accuracy | ±1% of range |
Certifications/Compliance | ETL, CSA, UL, CE, UKCA |
Depth (English) | 23 in. |
Depth (Metric) | 584 mm |
Description | Direct Methane and Non-Methane Hydrocarbon Analyzer |
Detection Limit | 0.050 ppm CH4 - 0.050 NMHC as propane (300 second averaging time) |
Frequency | 50/60 Hz |
Height (English) | 8.62 in. |
Height (Metric) | 219 mm |
Measurement Range | 0 to 5, 50, 500 ppm, or 0 to 10, 100, 1000 ppm, or 0 to 20, 200, 2000 ppm , or 0 to 50, 500, 5000 ppm (Group selectable at time of order) |
Mounting Options | Bench, EIA rack, Retrofit rack |
Outputs | Analog outputs: 6 voltage outputs; 0 to 100mV, 1, 5, 10V (user selectable), 5% of full-scale over/under range (user selectable), 12 bit resolution, measurement output user selectable per channelDigital outputs: 1 power fail relay Form C, 10 relays Form A, user-selectable alarm output, relay logic, 100mA at 200VDCDigital inputs: 16 digital inputs, user select programmable, TTL level, pulled high |
Precision | 2.0% of reading or 50 ppb (whichever is larger) |
Voltage | 100/115/220/240 V |
Weight (English) | 60 lb. |
Weight (Metric) | 17.7 kg |
Width (English) | 16.75 in. |
Width (Metric) | 425 mm |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
55I | Each | Direct Methane and Non-Methane Hydrocarbon Analyzer | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Automated batch analyzer repeatedly collects and analyzes small amounts of the sample stream drawn in by the pump. Central to the instrument's operation is an eight-port, two-position rotary valve which is used to introduce the gas sample into the analyzer and to control the flow of gases through the chromatographic column. The proprietary column design is unaffected by the oxygen content of the sample and provides complete recovery of low volatility compounds while achieving absolute separation of methane from all C2 compounds.
iSeries Advantage: