Easily implement laboratory-based FT-NIR performance in a ready-for-plant package using the Thermo Scientific™ Antaris™ II FT-NIR Analyzer. With industry-leading method transfer performance, the Antaris II FT-NIR Analyzer provides robust and reliable data collection for at-line, online and in-line analysis. You can customize an Antaris II FT-NIR Analyzer for specific applications or choose the Antaris II MDS Method Development Sampling System, which includes transmission, fiber-optic and integrating sphere diffuse reflection analysis all in one turnkey system.

 
Catalog Number
IQLAADGABCFADUMAAV
Unit Size
Each
Description
Thermo Scientific™ Antaris™ II FT-NIR Analyzer sets an industry standard, providing laboratory-based FT-NIR performance in a ready-for-plant package.
Source Type
Long-life, high intensity halogen NIR source; spare source included with system, guaranteed filament image alignment
Spectral Range
12,000 to 3800 cmto1 (833 to 2630 nm)
Price (USD)
Full specifications
Product TypeAntaris II FT-NIR Analyzer
DescriptionThermo Scientific™ Antaris™ II FT-NIR Analyzer sets an industry standard, providing laboratory-based FT-NIR performance in a ready-for-plant package.
Analyzer TypeFourier Transform Near-Infrared
DetectionHigh sensitivity, high stability matched InGaAs
Height (Metric)33 cm
InterfaceDirect PC to Ethernet allows file system and OPC communications
InterferometerProven, frictionless, stable, long-life Michelson
Length (Metric)68.5 cm
Operating Temperature Range15°C to 35°C (59° to 95°F)
Photometric LinearitySlope 1.0 ±0.05 and an intercept of 0.0 ±0.05
Resolution4 cm-1 across spectral range (0.6 nm at 1250 nm), 2 cm-1 option across spectral range (0.3 nm at 1250 nm)
Sampling ModeConfigurable with reflection, transmission, fiber optics, or tablet transmission.
Sealed and DesiccatedYes
Source TypeLong-life, high intensity halogen NIR source; spare source included with system, guaranteed filament image alignment
Spectral Range12,000 to 3800 cmto1 (833 to 2630 nm)
System Status IndicatorsYes
Voltage90/264 V
Wavenumber Accuracy±0.03 cm-1 (0.005 nm at 1250 nm)
Wavenumber RepeatabilitySingle System: 10 measurement standard deviation <0.006 cm-1
Wavenumber ReproducibilitySystem to System: Better than 0.05 cm-1 (0.008 nm at 1250 nm)
Weight (Metric)47.7 kg
Width (Metric)40.6 cm
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionSource TypeSpectral RangePrice (USD)
IQLAADGABCFADUMAAVFull specifications
EachThermo Scientific™ Antaris™ II FT-NIR Analyzer sets an industry standard, providing laboratory-based FT-NIR performance in a ready-for-plant package.Long-life, high intensity halogen NIR source; spare source included with system, guaranteed filament image alignment12,000 to 3800 cmto1 (833 to 2630 nm)Request A Quote
Product TypeAntaris II FT-NIR Analyzer
DescriptionThermo Scientific™ Antaris™ II FT-NIR Analyzer sets an industry standard, providing laboratory-based FT-NIR performance in a ready-for-plant package.
Analyzer TypeFourier Transform Near-Infrared
DetectionHigh sensitivity, high stability matched InGaAs
Height (Metric)33 cm
InterfaceDirect PC to Ethernet allows file system and OPC communications
InterferometerProven, frictionless, stable, long-life Michelson
Length (Metric)68.5 cm
Operating Temperature Range15°C to 35°C (59° to 95°F)
Photometric LinearitySlope 1.0 ±0.05 and an intercept of 0.0 ±0.05
Resolution4 cm-1 across spectral range (0.6 nm at 1250 nm), 2 cm-1 option across spectral range (0.3 nm at 1250 nm)
Sampling ModeConfigurable with reflection, transmission, fiber optics, or tablet transmission.
Sealed and DesiccatedYes
Source TypeLong-life, high intensity halogen NIR source; spare source included with system, guaranteed filament image alignment
Spectral Range12,000 to 3800 cmto1 (833 to 2630 nm)
System Status IndicatorsYes
Voltage90/264 V
Wavenumber Accuracy±0.03 cm-1 (0.005 nm at 1250 nm)
Wavenumber RepeatabilitySingle System: 10 measurement standard deviation <0.006 cm-1
Wavenumber ReproducibilitySystem to System: Better than 0.05 cm-1 (0.008 nm at 1250 nm)
Weight (Metric)47.7 kg
Width (Metric)40.6 cm
Unit SizeEach
Showing 1 of 1

The Antaris II FT-NIR Analyzer Allows You To:

  • Analyze any sample type rapidly and accurately
  • Make regulatory compliance (DQ, IQ, OQ and PQ) easy with the Thermo Scientific™ ValPro™ Instrument Qualification Package
  • Reproduce results regardless of configuration, maintenance, user or environment
  • Achieve fast, precise and accurate measurements in the lab or in the plant

Ordering Information:
The Antaris II FT-NIR Analyzer is sold as a configured system designed to meet your specific needs. For more information, contact your Thermo Scientific Sales Representative.

Recommended for:

  • Solids
  • Powders
  • Grains
  • Tablets
  • Paste
  • Gel
  • Syrup
  • Films
  • Liquids

Figures