Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Measure trace levels of carbon monoxide (CO) in ambient air with the Thermo Scientific™ Model 48i-TLE Enhanced Trace Level CO Analyzer, which utilizes gas filter correlation and NDIR technology. The enhanced sample conditioned temperature stabilization and auto-zeroing of the Model 48-TLE result in a low detection limit for the measurement of carbon monoxide.
Discover the iQ to work smarter with our next generation 48iQ Trace Level Carbon Monoxide Analyzer.
Detectable Analytes | Carbon Monoxide |
Flow Rate | 0.5 L/min. |
Inputs | 16 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional) |
Linearity | ±1% full scale |
Response Time | 60 sec. (30 sec. average time) |
Span Drift | ±1% full scale |
Temperature (English) Operating | 68°F to 86°F |
Temperature (Metric) Operating | 20°C to 30°C |
Certifications/Compliance | ETL, CSA, UL, CE; U.S. EPA (RFCA-0981-054), UKCA |
Depth (English) | 23 in. |
Depth (Metric) | 584 mm |
Description | Model 48i-TLE Enhanced Trace Level CO Analyzer |
Detection Limit | 0.04 ppm (30 second averaging time) |
Height (English) | 8.62 in. |
Height (Metric) | 219 mm |
Measurement Range | Preset: 0 to 50, 100, 200, 500, 1000, 2000, 5000, 10000 and 20000 ppm; 0 to 50, 100, 200, 500, 1000, 2000, 5000, 10000 and 20000 mg/m3; Custom: 0 to 50 to 20000 ppm, 0-50 to 20000 mg/m3 |
Outputs | Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard); 0 to 20 or 4 to 20mA Isolated Current Outout (optional) |
Voltage | 100/115 VAC, 220/240 VAC |
Weight (English) | 55 lb. |
Weight (Metric) | 25 kg |
Width (English) | 16.75 in. |
Width (Metric) | 425 mm |
Zero Drift | <0.1ppm |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48I-TLE | Each | Model 48i-TLE Enhanced Trace Level CO Analyzer | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Key Features:
iSeries Advantage:
Ordering Information:
Choose from the following configurations/options to customize:
Voltage options
A:120VAC 50/60Hz
B: 220VAC 50/60Hz
J: 100VAC 50/60Hz
Internal zero/span
C: Internal zero / span valves w/zero air scrubber
Filter Wheel Purge
P: Filter wheel purge set-up
Optional I/O
A: No optional I/O (standard)
C: 0-20, 4-20mA current output - 6 channels, 0-10V analog input - 8 channels
Mounting hardware
A: Bench mounting (standard)
B: Ears and handles, EIA
C: Ears and handles, retrofit