Thermo Scientific™

Dionex™ DRS 600 Dynamically Regenerated Suppressor

Catalog number: 088666
Thermo Scientific™

Dionex™ DRS 600 Dynamically Regenerated Suppressor

Catalog number: 088666

Use the Thermo Scientific™ Dionex™ DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC™) system.

 
Catalog Number
088666
Unit Size
Each 1
Description
Dionex ADRS 600 Anion Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082540 Dionex AERS Anion Electrolytically Regenerated Suppressor (4 mm))
Price (USD)
Price: 1,350.00
Your price:
Availability
-
Full specifications
Quantity
TypeAnion Dynamically Regenerated Suppressor
Flow Rate3 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage500 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex ADRS 600 Anion Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082540 Dionex AERS Anion Electrolytically Regenerated Suppressor (4 mm))
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Description
Dionex ADRS 600 Anion Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082541 Dionex AERS Anion Electrolytically Regenerated Suppressor (2 mm))
Price (USD)
Price: 1,350.00
Your price:
Availability
-
Full specifications
Quantity
TypeAnion Dynamically Regenerated Suppressor
Flow Rate1 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage150 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex ADRS 600 Anion Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082541 Dionex AERS Anion Electrolytically Regenerated Suppressor (2 mm))
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Description
Dionex CDRS 600 Cation Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082542 Dionex CERS Cation Electrolytically Regenerated Suppressor (4 mm))
Price (USD)
Price: 1,350.00
Your price:
Availability
-
Full specifications
Quantity
TypeCation Dynamically Regenerated Suppressor
Flow Rate3 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage300 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex CDRS 600 Cation Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082542 Dionex CERS Cation Electrolytically Regenerated Suppressor (4 mm))
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Description
Dionex CDRS 600 Cation Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082543 Dionex CERS Cation Electrolytically Regenerated Suppressor (2 mm))
Price (USD)
Price: 1,350.00
Your price:
Availability
-
Full specifications
Quantity
TypeCation Dynamically Regenerated Suppressor
Flow Rate0.75 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage110 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex CDRS 600 Cation Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082543 Dionex CERS Cation Electrolytically Regenerated Suppressor (2 mm))
Unit SizeEach 1
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)AvailabilityQuantity
088666Full specifications
Each 1Dionex ADRS 600 Anion Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082540 Dionex AERS Anion Electrolytically Regenerated Suppressor (4 mm))
Price: 1,350.00
Your price:
-
TypeAnion Dynamically Regenerated Suppressor
Flow Rate3 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage500 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex ADRS 600 Anion Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082540 Dionex AERS Anion Electrolytically Regenerated Suppressor (4 mm))
Unit SizeEach 1
088667Full specifications
Each 1Dionex ADRS 600 Anion Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082541 Dionex AERS Anion Electrolytically Regenerated Suppressor (2 mm))
Price: 1,350.00
Your price:
-
TypeAnion Dynamically Regenerated Suppressor
Flow Rate1 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage150 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex ADRS 600 Anion Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082541 Dionex AERS Anion Electrolytically Regenerated Suppressor (2 mm))
Unit SizeEach 1
088668Full specifications
Each 1Dionex CDRS 600 Cation Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082542 Dionex CERS Cation Electrolytically Regenerated Suppressor (4 mm))
Price: 1,350.00
Your price:
-
TypeCation Dynamically Regenerated Suppressor
Flow Rate3 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage300 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex CDRS 600 Cation Dynamically Regenerated Suppressor (4 mm)
(Replacement for P/N 082542 Dionex CERS Cation Electrolytically Regenerated Suppressor (4 mm))
Unit SizeEach 1
088670Full specifications
Each 1Dionex CDRS 600 Cation Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082543 Dionex CERS Cation Electrolytically Regenerated Suppressor (2 mm))
Price: 1,350.00
Your price:
-
TypeCation Dynamically Regenerated Suppressor
Flow Rate0.75 mL/min. Max.
Pressure30 to 100 psi (recommended)
OperationUsed for electrolytically regenerated suppression in ion chromatography.
Amperage110 mA
For Use With (Application)Ion Chromatography Applications Requiring High Capacity, Low Noise, High Backpressure Resiliency, and Fast Startup
Temperature Range15°C to 50°C
DescriptionDionex CDRS 600 Cation Dynamically Regenerated Suppressor (2 mm)
(Replacement for P/N 082543 Dionex CERS Cation Electrolytically Regenerated Suppressor (2 mm))
Unit SizeEach 1
Showing 4 of 4
Dionex DRS 600 makes analysis easier for system operators
  • Minimizes training and operation time by eliminating error-prone manual calculation of electrical currents
  • Improves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent composition
Compatible across a wide variety of applications

The Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).

The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor.

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for six (6) months thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text