Thermo Scientific™

Consumables and Services Kits for Orion™ 2110XP Ammonia Analyzer

Número de catálogo: 210056
Thermo Scientific™

Consumables and Services Kits for Orion™ 2110XP Ammonia Analyzer

Número de catálogo: 210056
Keep needed supplies and service items in stock to avoid lost productivity with Thermo Scientific™ Consumables and Services Kits for the Thermo Scientific™ Orion™ 2110XP Ammonia Analyzer.
 
Número de catálogo
210056
Formato
Each
Descripción
Reference Electrode Half-Cell for use with 2110XP, 2111XP Analyzers
Especificaciones completas
DescripciónReference Electrode Half-Cell for use with 2110XP, 2111XP Analyzers
TipoConsumables and Services Kit
Para utilizar con (equipo)2110XP, 2111XP Analyzers
Unit SizeEach
Número de catálogo
Formato
Each
Descripción
Ammonia Consumables Kit for one year operation
Especificaciones completas
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónAmmonia Consumables Kit for one year operation
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla211050XP
Caudal40 mL/min.
Incluye2 x 2L acetic acid reagent (181030), 2 x 4 ft. diffusion tubing assemblies with O-rings (150060), reagent bottle adapter (2110RBA), ammonia calibration standards kit (181040), ammonia electrode (100047), reference electrode (210056), 5 x 2 oz. reference electrode filling solution (181073), O-ring kit (2110OK), restriction tube assembly (2100RT), 4 inlet filters (181120) and box of pipette tips (204846-001)
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuesta211050XP
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
Número de catálogo
Formato
Each
Descripción
Reagent-less Ammonia Consumables Kit - for one year operation
Especificaciones completas
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónReagent-less Ammonia Consumables Kit - for one year operation
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla211050XPF
Caudal40 mL/min.
Incluye2 x 2L empty bottles for acetic acid reagent, 2 x 4 ft. diffusion tubing assemblies with O-rings (150060), reagent bottle adapter (2110RBA), ammonia calibration standards kit (181040), ammonia electrode (100047), reference electrode (210056), 5 x 2 oz. reference electrode filling solution (181073), O-ring kit (2110OK), restriction tube assembly (2100RT), 4 inlet filters (181120) and box of pipette tips (204846-001)
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuestaInitial response within 15 seconds, reach 90% of reading within 1 minute of injecting a standard solution
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
Número de catálogo
Formato
Each
Descripción
Ammonia Calibration Kit with Carrying Case
Especificaciones completas
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónAmmonia Calibration Kit with Carrying Case
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla2110XPCAL
Caudal40 mL/min.
Incluye0.5mL pipette (204847-001), box of pipette tips (204846-001), ammonia calibration standards kit (181040), wash bottle and inlet filter
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuesta2110XPCAL
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
Número de catálogo
Formato
Each
Descripción
Ammonia Electrode Kit - includes ammonia electrode, reference electrode and 2 oz. reference electrode filling solution
Especificaciones completas
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónAmmonia Electrode Kit - includes ammonia electrode, reference electrode and 2 oz. reference electrode filling solution
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla2110XPEK
Caudal40 mL/min.
Incluyeammonia electrode (100047), reference electrode (210056) and 2 oz. reference electrode filling solution (181073)
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuestaInitial response within 15 seconds, reach 90% of reading within 1 minute of injecting a standard solution
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
Número de catálogo
Formato
Each
Descripción
2110XP Electronics Faceplate
Especificaciones completas
Descripción2110XP Electronics Faceplate
Temperatura de funcionamiento (métrico)5°C to 45°C (Sample)
TipoConsumables and Services Kit
Unit SizeEach
Número de catálogo
Formato
Each
Descripción
2110XP Service Kit
Especificaciones completas
Exactitud (mV)±(0.5 mV + 0.1%)
Descripción2110XP Service Kit
Temperatura de funcionamiento (métrico)5°C to 45°C (Sample)
TipoConsumables and Services Kit
Incluyeelectronics faceplate (2110XPEP), air pump assembly (2100PA), regulator assembly (2100RG), 2 electrode cables with gland assemblies for sensing and reference electrodes (2100EC), power supply assembly (2100PS) and fuse kit assembly (2100FK115 and 2100FK230)
Tiempo de respuestaInitial response within 15 seconds, reach 90% of reading within 1 minute of injecting a standard solution
Unit SizeEach
Mostrando 7 de 7
Número de catálogoEspecificacionesFormatoDescripciónPrecio (EUR)
210056Especificaciones completas
EachReference Electrode Half-Cell for use with 2110XP, 2111XP AnalyzersSolicite un presupuesto
DescripciónReference Electrode Half-Cell for use with 2110XP, 2111XP Analyzers
TipoConsumables and Services Kit
Para utilizar con (equipo)2110XP, 2111XP Analyzers
Unit SizeEach
211050XPEspecificaciones completas
EachAmmonia Consumables Kit for one year operationSolicite un presupuesto
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónAmmonia Consumables Kit for one year operation
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla211050XP
Caudal40 mL/min.
Incluye2 x 2L acetic acid reagent (181030), 2 x 4 ft. diffusion tubing assemblies with O-rings (150060), reagent bottle adapter (2110RBA), ammonia calibration standards kit (181040), ammonia electrode (100047), reference electrode (210056), 5 x 2 oz. reference electrode filling solution (181073), O-ring kit (2110OK), restriction tube assembly (2100RT), 4 inlet filters (181120) and box of pipette tips (204846-001)
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuesta211050XP
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
211050XPFEspecificaciones completas
EachReagent-less Ammonia Consumables Kit - for one year operationSolicite un presupuesto
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónReagent-less Ammonia Consumables Kit - for one year operation
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla211050XPF
Caudal40 mL/min.
Incluye2 x 2L empty bottles for acetic acid reagent, 2 x 4 ft. diffusion tubing assemblies with O-rings (150060), reagent bottle adapter (2110RBA), ammonia calibration standards kit (181040), ammonia electrode (100047), reference electrode (210056), 5 x 2 oz. reference electrode filling solution (181073), O-ring kit (2110OK), restriction tube assembly (2100RT), 4 inlet filters (181120) and box of pipette tips (204846-001)
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuestaInitial response within 15 seconds, reach 90% of reading within 1 minute of injecting a standard solution
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
2110XPCALEspecificaciones completas
EachAmmonia Calibration Kit with Carrying CaseSolicite un presupuesto
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónAmmonia Calibration Kit with Carrying Case
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla2110XPCAL
Caudal40 mL/min.
Incluye0.5mL pipette (204847-001), box of pipette tips (204846-001), ammonia calibration standards kit (181040), wash bottle and inlet filter
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuesta2110XPCAL
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
2110XPEKEspecificaciones completas
EachAmmonia Electrode Kit - includes ammonia electrode, reference electrode and 2 oz. reference electrode filling solutionSolicite un presupuesto
Exactitud (mV)±(0.5 mV + 0.1%)
Exactitud (temperatura)±0.5 °C
DescripciónAmmonia Electrode Kit - includes ammonia electrode, reference electrode and 2 oz. reference electrode filling solution
Temperatura de funcionamiento (métrico)-10°C to +120°C
TipoConsumables and Services Kit
Tipo de pantalla2110XPEK
Caudal40 mL/min.
Incluyeammonia electrode (100047), reference electrode (210056) and 2 oz. reference electrode filling solution (181073)
Presión de entrada8 to 100 psig
Entradas85-132; 170-264 VAC
SalidasAlarm: 3; Relay: 3; Analog: 2; Selections: 0-20mA; 4-20 mA
Intervalo (mV)±1999.9 m
Detalles del reléMax Load: 250VAC; 30VDC; 5A
Resolución (mV)0.1 mV
Resolución (temperatura)0.1 °C
Tiempo de respuestaInitial response within 15 seconds, reach 90% of reading within 1 minute of injecting a standard solution
Entrada de muestras0.25 NPTF Tube Fitting in.
Temperatura de las muestras5 to 45 °C
Unit SizeEach
2110XPEPEspecificaciones completas
Each2110XP Electronics FaceplateSolicite un presupuesto
Descripción2110XP Electronics Faceplate
Temperatura de funcionamiento (métrico)5°C to 45°C (Sample)
TipoConsumables and Services Kit
Unit SizeEach
2110XPSKEspecificaciones completas
Each2110XP Service KitSolicite un presupuesto
Exactitud (mV)±(0.5 mV + 0.1%)
Descripción2110XP Service Kit
Temperatura de funcionamiento (métrico)5°C to 45°C (Sample)
TipoConsumables and Services Kit
Incluyeelectronics faceplate (2110XPEP), air pump assembly (2100PA), regulator assembly (2100RG), 2 electrode cables with gland assemblies for sensing and reference electrodes (2100EC), power supply assembly (2100PS) and fuse kit assembly (2100FK115 and 2100FK230)
Tiempo de respuestaInitial response within 15 seconds, reach 90% of reading within 1 minute of injecting a standard solution
Unit SizeEach
Mostrando 7 de 7
Keep needed supplies and service items in stock to avoid lost productivity with Thermo Scientific™ Consumables and Services Kits for the Thermo Scientific™ Orion™ 2110XP Ammonia Analyzer.
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figuras

Documentos y descargas

Certificados

    Preguntas frecuentes

    Citas y referencias

    Search citations by name, author, journal title or abstract text