Thermo Scientific™

Orion™ AQUAfast™ IV Chemistry Reagents

Catalog number: AC4004
Thermo Scientific™

Orion™ AQUAfast™ IV Chemistry Reagents

Catalog number: AC4004

Minimize the risks of improper measurement and contamination with Thermo Scientific™ Orion™ AQUAfast™ IV Chemistry Reagents, which are contained in self-filling vials. Use these reagents with the Orion™ AQUAfast AQ4000 colorimeter to simplify sample preparation and tests. The auto-test ampoules contain a pre-measured amount of liquid reagent and easily fill with the correct volume of sample for simple and fast sample and reagent mixing. Each ampoule contains an Auto-ID barcode that is read by the AQ4000 colorimeter and used to automatically identify the test parameter and initiates the test.

 
Catalog Number
AC4004
Unit Size
Case of 30
Range
0.2 to 1.5 mg/L N
Type
Nitrate
Method
Cadmium Reduction
Price (USD)
Price: 151.00
Your price:
Availability
-
Full specifications
Quantity
TypeNitrate
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast nitrate LR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodCadmium Reduction
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.2 to 1.5 mg/L N
EPA Approved MethodsDrinking Water: ASTM D3867-90 (B) / Standard Methods 4500-NO3- E; Wastewater: ASTM D3867-04 (B) / Standard Methods 4500-NO3- E
Quantity30 Ampoules
Unit SizeCase of 30
Catalog Number
Unit Size
Each
Range
0.04 to 0.4 mg/L
Type
Cyanide
Method
Price (USD)
Price: 104.00
Your price:
Availability
-
Full specifications
Quantity
TypeCyanide
For Use With (Equipment)AQ4000
DescriptionAQUAfast cyanide (free) auto-id ampoules, 30 tests
Range0.04 to 0.4 mg/L
Unit SizeEach
Catalog Number
Unit Size
Case of 30
Range
1.0 to 7.5 mg/L N
Type
Nitrate
Method
Cadmium Reduction
Price (USD)
Price: 145.00
Your price:
Availability
-
Full specifications
Quantity
TypeNitrate
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast nitrate MR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodCadmium Reduction
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range1.0 to 7.5 mg/L N
EPA Approved MethodsDrinking Water: ASTM D3867-90 (B) / Standard Methods 4500-NO3- E; Wastewater: ASTM D3867-04 (B) / Standard Methods 4500-NO3- E
Quantity30 Ampoules
Unit SizeCase of 30
Catalog Number
Unit Size
Case of 30
Range
5 to 50 mg/L NO3
Type
Nitrate
Method
Cadmium Reduction
Price (USD)
Price: 123.00
Your price:
Availability
-
Full specifications
Quantity
TypeNitrate
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast nitrate HR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodCadmium Reduction
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range5 to 50 mg/L NO3
EPA Approved MethodsDrinking Water: ASTM D3867-90 (B) / Standard Methods 4500-NO3- E; Wastewater: ASTM D3867-04 (B) / Standard Methods 4500-NO3- E
Quantity30 Ampoules
Unit SizeCase of 30
Catalog Number
Unit Size
Each
Range
0.2 to 3 mg/L N
Type
Ammonia
Method
Salicylate
Price (USD)
Price: 55.20
Your price:
Availability
-
Full specifications
Quantity
TypeAmmonia
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast ammonia ULR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodSalicylate
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.2 to 3 mg/L N
Quantity30 Ampoules
Unit SizeEach
Catalog Number
Unit Size
Case of 30
Range
1.5 to 14 mg/L N
Type
Ammonia
Method
Direct Nesslerization
Price (USD)
Price: 76.30
Your price:
Availability
-
Full specifications
Quantity
TypeAmmonia
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast ammonia HR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodDirect Nesslerization
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range1.5 to 14 mg/L N
EPA Approved MethodsWastewater: ASTM D1426-08 (A)
Quantity30 Ampoules
Unit SizeCase of 30
Catalog Number
Unit Size
Case of 30
Range
0.5 to 7 mg/L N
Type
Ammonia
Method
Direct Nesslerization
Price (USD)
Price: 78.40
Your price:
Availability
-
Full specifications
Quantity
TypeAmmonia
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast ammonia LR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodDirect Nesslerization
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.5 to 7 mg/L N
EPA Approved MethodsWastewater: ASTM D1426-08 (A)
Quantity30 Ampoules
Unit SizeCase of 30
Catalog Number
Unit Size
Case of 30
Range
0.2 to 3 mg/L S
Type
Sulfide
Method
Methylene Blue
Price (USD)
Price: 74.50
Your price:
Availability
-
Full specifications
Quantity
TypeSulfide
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast sulfide (Acid Soluble) Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodMethylene Blue
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.2 to 3 mg/L S
EPA Approved MethodsWastewater: Standard Methods 4500-S2- D
Quantity30 Ampoules
Unit SizeCase of 30
Catalog Number
Unit Size
Case of 30
Range
2.5 to 40 mg/L Cl-
Type
Chloride
Method
Ferric Thiocyanide
Price (USD)
Price: 68.00
Your price:
Availability
-
Full specifications
Quantity
TypeChloride
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast chloride Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodFerric Thiocyanide
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range2.5 to 40 mg/L Cl-
EPA Approved MethodsWastewater: Standard Methods 4500-Cl- E-1997
Quantity30 Ampoules
Unit SizeCase of 30
Catalog Number
Unit Size
Case of 30
Range
0.04 to 0.25 mg/L Al
Type
Aluminum
Method
Eriochrome Cyanine R
Price (USD)
Availability
-
Full specifications
Quantity
-
TypeAluminum
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast aluminum Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodEriochrome Cyanine R
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.04 to 0.25 mg/L Al
EPA Approved MethodsWastewater: Standard Methods 3500-Al B-2001
Quantity30 Ampoules
Unit SizeCase of 30
Showing 10 of 20Show more
Catalog NumberSpecificationsUnit SizeRangeTypeMethodPrice (USD)AvailabilityQuantity
AC4004Full specifications
Case of 300.2 to 1.5 mg/L NNitrateCadmium Reduction
Price: 151.00
Your price:
-
TypeNitrate
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast nitrate LR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodCadmium Reduction
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.2 to 1.5 mg/L N
EPA Approved MethodsDrinking Water: ASTM D3867-90 (B) / Standard Methods 4500-NO3- E; Wastewater: ASTM D3867-04 (B) / Standard Methods 4500-NO3- E
Quantity30 Ampoules
Unit SizeCase of 30
AC4006Full specifications
Each0.04 to 0.4 mg/LCyanide
Price: 104.00
Your price:
-
TypeCyanide
For Use With (Equipment)AQ4000
DescriptionAQUAfast cyanide (free) auto-id ampoules, 30 tests
Range0.04 to 0.4 mg/L
Unit SizeEach
AC4005Full specifications
Case of 301.0 to 7.5 mg/L NNitrateCadmium Reduction
Price: 145.00
Your price:
-
TypeNitrate
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast nitrate MR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodCadmium Reduction
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range1.0 to 7.5 mg/L N
EPA Approved MethodsDrinking Water: ASTM D3867-90 (B) / Standard Methods 4500-NO3- E; Wastewater: ASTM D3867-04 (B) / Standard Methods 4500-NO3- E
Quantity30 Ampoules
Unit SizeCase of 30
AC4007Full specifications
Case of 305 to 50 mg/L NO3NitrateCadmium Reduction
Price: 123.00
Your price:
-
TypeNitrate
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast nitrate HR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodCadmium Reduction
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range5 to 50 mg/L NO3
EPA Approved MethodsDrinking Water: ASTM D3867-90 (B) / Standard Methods 4500-NO3- E; Wastewater: ASTM D3867-04 (B) / Standard Methods 4500-NO3- E
Quantity30 Ampoules
Unit SizeCase of 30
AC4010Full specifications
Each0.2 to 3 mg/L NAmmoniaSalicylate
Price: 55.20
Your price:
-
TypeAmmonia
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast ammonia ULR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodSalicylate
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.2 to 3 mg/L N
Quantity30 Ampoules
Unit SizeEach
AC4011Full specifications
Case of 301.5 to 14 mg/L NAmmoniaDirect Nesslerization
Price: 76.30
Your price:
-
TypeAmmonia
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast ammonia HR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodDirect Nesslerization
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range1.5 to 14 mg/L N
EPA Approved MethodsWastewater: ASTM D1426-08 (A)
Quantity30 Ampoules
Unit SizeCase of 30
AC4012Full specifications
Case of 300.5 to 7 mg/L NAmmoniaDirect Nesslerization
Price: 78.40
Your price:
-
TypeAmmonia
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast ammonia LR Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodDirect Nesslerization
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.5 to 7 mg/L N
EPA Approved MethodsWastewater: ASTM D1426-08 (A)
Quantity30 Ampoules
Unit SizeCase of 30
AC4016Full specifications
Case of 300.2 to 3 mg/L SSulfideMethylene Blue
Price: 74.50
Your price:
-
TypeSulfide
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast sulfide (Acid Soluble) Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodMethylene Blue
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.2 to 3 mg/L S
EPA Approved MethodsWastewater: Standard Methods 4500-S2- D
Quantity30 Ampoules
Unit SizeCase of 30
AC4017Full specifications
Case of 302.5 to 40 mg/L Cl-ChlorideFerric Thiocyanide
Price: 68.00
Your price:
-
TypeChloride
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast chloride Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodFerric Thiocyanide
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range2.5 to 40 mg/L Cl-
EPA Approved MethodsWastewater: Standard Methods 4500-Cl- E-1997
Quantity30 Ampoules
Unit SizeCase of 30
AC4027Full specifications
Case of 300.04 to 0.25 mg/L AlAluminumEriochrome Cyanine RContact Us ›--
TypeAluminum
Test Reagent FormatsAmpoule
For Use With (Equipment)Orion AQUAfast AQ4000 Colorimeter
DescriptionAQUAfast aluminum Auto-ID ampoules, 30 pack
Includes30 Auto-ID Ampoules
MethodEriochrome Cyanine R
For Use With (Application)Colorimetric water and wastewater testing equipment
Recommended AccessoriesAQUAfast Zero Vial Auto-Test Kit (Cat. No. AQ4ZER)
Range0.04 to 0.25 mg/L Al
EPA Approved MethodsWastewater: Standard Methods 3500-Al B-2001
Quantity30 Ampoules
Unit SizeCase of 30
Showing 10 of 20Show more
  • No. of test: 30
  • Consistency and reproducibility improved with AQUAfast ampoules and an AQ4000 meter
  • Thermo Scientific™ Auto-ID™ eliminates measurement errors
Warranty: Out of box
Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text