Thermo Fisher Scientific

Where forward-thinking scientists, educators and safety professionals come to share and discover information that makes the world a cleaner, safer & healthier place to live.

  • Categories
    • Advancing Materials
    • Advancing Mining
    • AnalyteGuru
    • Analyzing Metals
    • Ask a Scientist
    • Behind the Bench
    • Biotech at Scale
    • Clinical Conversations
    • Examining Food
    • Identifying Threats
    • Illuminating Semiconductors
    • Life in Atomic Resolution
    • Life in the Lab
    • OEMpowered
    • The Connected Lab
  • About Us
  • Contact
Michael Bradley

Expertise

Applications of High PressureFluorescenceFTIRFTIR MicroscopyIR SpectrometryPhysical Chemistry Professor

Education

-University of Wisconsin-Whitewater: Master of Business Administration (M.B.A.),
-University of Illinois Urbana-Champaign: Ph.D., Physical Chemistry
-University of South Carolina: B.S., Chemistry, Computer Science

Michael Bradley

Retired Product Manager, FTIR and FTIR Microscopy, Thermo Fisher Scientific

Publications

  • Michael S. Bradley, PhD (November 1, 2015). Lineshapes in IR and Raman Spectroscopy: A Primer. Spectroscopy, 42–46.
  • Howard Mark, Mike Bradley (May 1, 2016). Review of New Spectroscopic Instrumentation 2016. Spectroscopy, 40–62.

Recognitions

  • Patent - Co-inventor, Spectrometer with built-in ATR and accessory compartment Spectrometer with built-in ATR and accessory compartment US 8547555 (Issued Oct 1, 2013)
  • Patent - Co-inventor, Multi-component regression/multi-component analysis of time series files Multi-component regression/multi-component analysis of time series files US 20130096883 (Issued Apr 18, 2013)
  • Patent - Co-inventor, Emission and transmission optical spectrometer Emission and transmission optical spectrometer US 20130063714 (Issued Mar 14, 2013)
  • R&D Magazine, R&D 100 Award (Team award) (Nov 2013)

Advancing Mining

jade cabbage carving

A Modern Look at Ancient Jade

May 23, 2017

Read more A Modern Look at Ancient Jade
blue diamonds

FT-IR Helps Uncover the Secrets of the Blue Moon

February 25, 2016

Read more FT-IR Helps Uncover the Secrets of the Blue Moon
jade ring

FT-IR Is an Effective Tool in Identifying Treated Jade

January 5, 2016

Read more FT-IR Is an Effective Tool in Identifying Treated Jade

Advancing Materials

mylar ballons ink

Monitoring the UV Cure Process of a Polymer Based Ink by FT-IR

July 30, 2025

Read more Monitoring the UV Cure Process of a Polymer Based Ink by FT-IR
soffitto san rocco

Using Microspectroscopy to Uncover the Science of Art

October 3, 2023

Read more Using Microspectroscopy to Uncover the Science of Art

Novel Germanium Semiconductor Materials Investigated with FTIR

July 22, 2021

Read more Novel Germanium Semiconductor Materials Investigated with FTIR

Using FTIR to Observe Chemical Reactions in Real Time

April 1, 2021

Read more Using FTIR to Observe Chemical Reactions in Real Time
car window tinting adhesive

FTIR Is an Ideal Technology for Studying Polymerization Reactions

April 18, 2017

Read more FTIR Is an Ideal Technology for Studying Polymerization Reactions
strong plastic car parts

FTIR Analyzes Polymer Composites for Material Qualification

April 4, 2017

Read more FTIR Analyzes Polymer Composites for Material Qualification
checking the quality of fashion eyeglass frames

FTIR and FT-NIR Help Improve Plastic Eyewear Options

November 29, 2016

Read more FTIR and FT-NIR Help Improve Plastic Eyewear Options
FTIR guide

FTIR: A Valuable Tool in Plastics Analysis

November 22, 2016

Read more FTIR: A Valuable Tool in Plastics Analysis
pit stop for checking tires

Race Safety Before The Pit Stop

November 15, 2016

Read more Race Safety Before The Pit Stop
eyeglasses need analysis in manufacturing

Plastic Offers Better Eyewear Options

September 27, 2016

Read more Plastic Offers Better Eyewear Options
FT-IR Glossary

Free Access to FTIR Resources for Educators, Students, and Everyone Else

August 30, 2016

Read more Free Access to FTIR Resources for Educators, Students, and Everyone Else
Futuristic Architecture

Modern Art with Fiber-reinforced Polymer Composites

August 16, 2016

Read more Modern Art with Fiber-reinforced Polymer Composites
police evidence

Analyzing Automotive Paints With Extended Range ATR is No Mystery

August 2, 2016

Read more Analyzing Automotive Paints With Extended Range ATR is No Mystery
thermoplastic airplane window

Thermoplastic Composites Improve Jets from the Inside

July 26, 2016

Read more Thermoplastic Composites Improve Jets from the Inside
bicycle race tire

The Tour de Tires

July 14, 2016

Read more The Tour de Tires
long highway road

Paving with Plastic: Could FTIR Help Make It a Reality?

June 21, 2016

Read more Paving with Plastic: Could FTIR Help Make It a Reality?
plastics engineering

Building a Better Plastic with FTIR

May 10, 2016

Read more Building a Better Plastic with FTIR

Polyethylene Challenges

April 21, 2016

Read more Polyethylene Challenges
Airplane flying above tropical sea at sunset

Polymer Composites Take Off

April 12, 2016

Read more Polymer Composites Take Off
lab equip for plastics and polymers

Is Your Lab Equipped To Analyze Polymers and Plastics?

April 7, 2016

Read more Is Your Lab Equipped To Analyze Polymers and Plastics?
chemicals in tubes

Advantages of FT-IR in Polymer Manufacturing

February 16, 2016

Read more Advantages of FT-IR in Polymer Manufacturing
FTIR Basic Organic Functional Group

FTIR Basic Organic Functional Group Reference Chart

December 21, 2015

Read more FTIR Basic Organic Functional Group Reference Chart
melted rubber duck

Applying TGA-IR to Your Deformulation Problems

November 23, 2015

Read more Applying TGA-IR to Your Deformulation Problems
video clip of instructor

3 Videos: FTIR Sampling Using ATR

November 17, 2015

Read more 3 Videos: FTIR Sampling Using ATR
black tires

Is ATR an Effective Sampling Technique for Carbon Black Rubber Analysis?

November 10, 2015

Read more Is ATR an Effective Sampling Technique for Carbon Black Rubber Analysis?
one bad pumpkin

What’s Wrong With That Plastic Pumpkin?

October 29, 2015

Read more What’s Wrong With That Plastic Pumpkin?
rubber ducks

New Approaches to Phthalate Testing Using FT-IR

July 21, 2015

Read more New Approaches to Phthalate Testing Using FT-IR
liquid adhesive

FT-IR Analysis Improves Adhesive and Sealant Product Quality

July 16, 2015

Read more FT-IR Analysis Improves Adhesive and Sealant Product Quality
july picnic table with food spread across a tablecloth

Happy Plastic Fourth of July!

July 2, 2015

Read more Happy Plastic Fourth of July!
The FT-IR Transmission Technique

The FT-IR Transmission Technique for Measuring Polymers

June 23, 2015

Read more The FT-IR Transmission Technique for Measuring Polymers
plastic crack spectra

FT-IR Spectrometer Discovers Cause of Plastic Fastener Cracking

June 2, 2015

Read more FT-IR Spectrometer Discovers Cause of Plastic Fastener Cracking
Poly Bracket Cracking

What Caused the Cracking of Poly Brackets?

March 31, 2015

Read more What Caused the Cracking of Poly Brackets?
Leaking tubing

Why Was The Plastic Tubing Leaking?

March 26, 2015

Read more Why Was The Plastic Tubing Leaking?
poly value failure analysis

Why Did the Poly Valves Fail?

March 24, 2015

Read more Why Did the Poly Valves Fail?
Attenuated Total Reflection (ATR) diagram

The Attenuated Total Reflection (ATR) Technique for Analyzing Plastics

March 12, 2015

Read more The Attenuated Total Reflection (ATR) Technique for Analyzing Plastics
FT-IR Sample Techniques

FT-IR Sample Handling Index, Methods, and Ratings [Infographic]

March 10, 2015

Read more FT-IR Sample Handling Index, Methods, and Ratings [Infographic]
FT-IR and True Specular Reflectance

Inspecting Polymers Using FT-IR and True Specular Reflectance

January 13, 2015

Read more Inspecting Polymers Using FT-IR and True Specular Reflectance

FTIR Diffuse Reflectance Sample Handling Technique for Polymers

December 23, 2014

Read more FTIR Diffuse Reflectance Sample Handling Technique for Polymers

Privacy StatementTerms & ConditionsLocationsSitemap

© 2026 Thermo Fisher Scientific. All Rights Reserved.

US

Talk to us