Thermo Scientific™

Dionex™ IonPac™ AS19 IC Columns

Catalog number: 062888
Thermo Scientific™

Dionex™ IonPac™ AS19 IC Columns

Catalog number: 062888
Measure trace bromate and other oxyhalides in drinking water, ground water, wastewater, and other diverse sample matrices with Thermo Scientific™ Dionex™ IonPac™ AS19 Capillary, Analytical & Guard Columns. The column is specifically designed and recommended for determination of trace bromate, a toxic byproduct of ozone disinfection. The column's high capacity and selectivity facilitate the determination of bromate in drinking water at the low-µg/L level. The Dionex IonPac AS19 columns meet the performance requirements of U.S. EPA Methods 300.0 and 300.1.
 
Catalog Number
062888
Unit Size
Each 1
Type
Microbore Guard Column
Diameter (Metric)
2 mm
Length (Metric)
50 mm
Price (USD)
436.82
Your Price:
Availability
***
Full specifications
Quantity
Certifications/ComplianceU.S. EPA Methods 300.0 and 300.1
Column Capacity1.5 µeq
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)Single Piston Pumps
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AG19
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Type
Standard Bore Analytical Column
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
1,316.90
Your Price:
Availability
***
Full specifications
Quantity
Packing MaterialPolymeric
Certifications/ComplianceMeets The Performance Requirements of US EPA Methods 300.0 and 300.1
Column Capacity240 µeq
Column ChemistryHydroxide
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)ASRS 300 with The IonPac AS19 Column for Eluent Suppression
HydrophobicityLow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7.5 µm
Stationary PhaseIonPac AS19
TypeStandard Bore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)4 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Anion Exchange Capacity240 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Type
Microbore Analytical Column
Diameter (Metric)
2 mm
Length (Metric)
250 mm
Price (USD)
1,316.90
Your Price:
Availability
***
Full specifications
Quantity
Packing MaterialPolymeric
Certifications/ComplianceMeets The Performance Requirements of US EPA Methods 300.0 and 300.1
Column Capacity60 µeq
Column ChemistryHydroxide
Flow Rate0.25 to 0.5 mL/min.
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)ASRS 300 with The IonPac AS19 Column for Eluent Suppression
HydrophobicityLow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7.5 µm
Stationary PhaseIonPac AS19
TypeMicrobore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)2 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Anion Exchange Capacity60 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Type
Standard Bore Guard Column
Diameter (Metric)
4 mm
Length (Metric)
50 mm
Price (USD)
436.82
Your Price:
Availability
***
Full specifications
Quantity
Certifications/ComplianceU.S. EPA Methods 300.0 and 300.1
Column Capacity6 µeq
For Use With (Application)Anion Exchange
For Use With (Equipment)Single Piston Pumps
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AS19
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Type
Capillary Column
Diameter (Metric)
0.4 mm
Length (Metric)
250 mm
Price (USD)
1,316.90
Your Price:
Availability
***
Full specifications
Quantity
Packing MaterialPolymeric
Certifications/ComplianceMeets The Performance Requirements of US EPA Methods 300.0 and 300.1
Column Capacity2.4 µeq
Column ChemistryHydroxide
Flow Rate0.01 to 0.02 mL/min.
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)ASRS 300 with The IonPac AS19 Column for Eluent Suppression
HydrophobicityLow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure5000 psi (345 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7.5 µm
Stationary PhaseIonPac AS19
TypeCapillary Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)0.4 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Anion Exchange Capacity2.4 µeq
Solvents0 to 100% of HPLC Solvents
DescriptionAS19; 0.4 x 250 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Type
Capillary Guard Column
Diameter (Metric)
0.4 mm
Length (Metric)
50 mm
Price (USD)
436.82
Your Price:
Availability
***
Full specifications
Quantity
Certifications/ComplianceU.S. EPA Methods 300.0 and 300.1
Column Capacity0.06 µeq
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)Analysis of Trace Bromate in Drinking Water
HydrophobicityLow
Max. Pressure5000 psi (345 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AG19
TypeCapillary Guard Column
Length (Metric)50 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
Showing 6 of 6
Catalog NumberSpecificationsUnit SizeTypeDiameter (Metric)Length (Metric)Price (USD)AvailabilityQuantity
062888Full specifications
Each 1Microbore Guard Column2 mm50 mm
436.82
Your Price:
***
Certifications/ComplianceU.S. EPA Methods 300.0 and 300.1
Column Capacity1.5 µeq
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)Single Piston Pumps
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AG19
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
062885Full specifications
Each 1Standard Bore Analytical Column4 mm250 mm
1,316.90
Your Price:
***
Packing MaterialPolymeric
Certifications/ComplianceMeets The Performance Requirements of US EPA Methods 300.0 and 300.1
Column Capacity240 µeq
Column ChemistryHydroxide
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)ASRS 300 with The IonPac AS19 Column for Eluent Suppression
HydrophobicityLow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7.5 µm
Stationary PhaseIonPac AS19
TypeStandard Bore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)4 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Anion Exchange Capacity240 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
062886Full specifications
Each 1Microbore Analytical Column2 mm250 mm
1,316.90
Your Price:
***
Packing MaterialPolymeric
Certifications/ComplianceMeets The Performance Requirements of US EPA Methods 300.0 and 300.1
Column Capacity60 µeq
Column ChemistryHydroxide
Flow Rate0.25 to 0.5 mL/min.
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)ASRS 300 with The IonPac AS19 Column for Eluent Suppression
HydrophobicityLow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7.5 µm
Stationary PhaseIonPac AS19
TypeMicrobore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)2 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Anion Exchange Capacity60 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
062887Full specifications
Each 1Standard Bore Guard Column4 mm50 mm
436.82
Your Price:
***
Certifications/ComplianceU.S. EPA Methods 300.0 and 300.1
Column Capacity6 µeq
For Use With (Application)Anion Exchange
For Use With (Equipment)Single Piston Pumps
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AS19
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
072064Full specifications
Each 1Capillary Column0.4 mm250 mm
1,316.90
Your Price:
***
Packing MaterialPolymeric
Certifications/ComplianceMeets The Performance Requirements of US EPA Methods 300.0 and 300.1
Column Capacity2.4 µeq
Column ChemistryHydroxide
Flow Rate0.01 to 0.02 mL/min.
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)ASRS 300 with The IonPac AS19 Column for Eluent Suppression
HydrophobicityLow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure5000 psi (345 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7.5 µm
Stationary PhaseIonPac AS19
TypeCapillary Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)0.4 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Anion Exchange Capacity2.4 µeq
Solvents0 to 100% of HPLC Solvents
DescriptionAS19; 0.4 x 250 mm
Unit SizeEach 1
072065Full specifications
Each 1Capillary Guard Column0.4 mm50 mm
436.82
Your Price:
***
Certifications/ComplianceU.S. EPA Methods 300.0 and 300.1
Column Capacity0.06 µeq
For Use With (Application)Analysis of Trace Bromate in Drinking Water
For Use With (Equipment)Analysis of Trace Bromate in Drinking Water
HydrophobicityLow
Max. Pressure5000 psi (345 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AG19
TypeCapillary Guard Column
Length (Metric)50 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
Showing 6 of 6
Reduce Operating Costs With our New Capillary Column

The Dionex IonPac AS19 Capillary column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column), but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.

Superior Chromatographic Performance
  • High capacity: 240µeq per column (4x250mm)
  • Operates at ambient or elevated temperatures with column selectivity optimized for 30°C
  • Compatible with organic solvents
  • Low background signal and enhanced analyte sensitivity when using the Thermo Scientific™
  • Dionex™ Anion Self-Regenerating Suppressor (ASRS™ 300) and a Reagent-Free™ (RFIC™) system
  • Analyze a Wide Range of Oxyhalides and Inorganic Anions
  • Oxyhalides and common inorganic anions including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate in drinking water, groundwater, wastewater, and other diverse sample matrices.
  • Analyzes most drinking water without the use of sample pretreatment or preconcentration.
  • Ideal when used with a Reagent-Free™ Ion Chromatography (RFIC)™ system for automatic eluent generation
Designed for Detection of Trace Bromate

The key application for this column is the determination of trace bromate in drinking water matrices using a potassium hydroxide gradient with suppressed conductivity detection. The column's selectivity ensures that bromate can be quantified at low µg/L concentrations using suppressed conductivity detection even in the presence of very high concentrations of chloride, sulfate, and carbonate.

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Frequently asked questions (FAQs)

Citations & References